A new method for improved standardisation in three-dimensional computed tomography cephalometry
- 1 February 2010
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 13 (1) , 59-69
Abstract
Interest for three-dimensional computed tomography cephalometry has risen over the last two decades. Current methods commonly rely on the examiner to manually point-pick the landmarks and/or orientate the skull. In this study, a new approach is presented, in which landmarks are calculated after selection of the landmark region on a triangular model and in which the skull is automatically orientated in a standardised way. Two examiners each performed five analyses on three skull models. Landmark reproducibility was tested by calculating the standard deviation for each observer and the difference between the mean values of both observers. The variation can be limited to 0.1 mm for most landmarks. However, some landmarks perform less well and require further investigation. With the proposed reference system, a symmetrical orientation of the skulls is obtained. The presented methods contribute to standardisation in cephalometry and could therefore allow improved comparison of patient data.Keywords
This publication has 25 references indexed in Scilit:
- Surgical Cephalometrics: Applications and DevelopmentsPlastic and Reconstructive Surgery, 2007
- Maxillofacial 3-dimensional image analysis for the diagnosis of facial asymmetryAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Comparison between traditional 2-dimensional cephalometry and a 3-dimensional approach on human dry skullsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2004
- A Simulator for Maxillofacial Surgery Integrating 3D Cephalometry and OrthodontiaComputer Aided Surgery, 2000
- Clinical usefulness of two-dimensional reformatted and three-dimensionally rendered computerized tomographic imagesJournal of Oral and Maxillofacial Surgery, 1995
- Validation study of skull three‐dimensional computerized tomography measurementsAmerican Journal of Physical Anthropology, 1990
- The three-dimensional cephalogram: Theory, techniques, and clinical applicationAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1988
- Sources of error in measurements from cephalometric radiographsEuropean Journal of Orthodontics, 1986
- The reliability of head film measurementsAmerican Journal of Orthodontics, 1971
- Die Bedeutung der Röntgenfern- und Abstandsaufnahme für die Diagnostik der KieferanomalienJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 1931