Cauter Van Sofie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Cauter Van Sofie has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Benedict Verhegghe
Ghent University, Ghent, Belgium
3 shared publications G. Brijs
Department of Oral and Maxillofacial Surgery , Heilige Familie General Hospital , Reet, Belgium
2 shared publicationsM. De Beule
IBiTech‐bioMMeda Ghent University Ghent Belgium
2 shared publications- Marc Braem
Department of Translational neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, 2610 Wilrijk, Belgium
2 shared publications W. Okkerse
Lab Dental Materials , Antwerp University , Antwerp, Belgium ; Department of Dentistry , Antwerp University Hospital , Antwerp, Belgium ; Department of Oral and Maxillofacial Surgery , Heilige Familie General Hospital , Reet, Belgium
2 shared publicationsA. Van Haver
Engineering Department Ghent University College Ghent Belgium
1 shared publication
Latest Publications
- 14 November 2011
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 28 (1) , 158-169
Automated extraction of the femoral anatomical axis for determining the intramedullary rod parameters in total knee arthroplasty
SUMMARY: The automated extraction of anatomical reference parameters may improve speed, precision and accuracy of surgical procedures. In this study, an automated method for extracting the femoral anatomical axis (FAA) from a 3D surface mesh, based on geometrical entity fitting, is presented. This was applied to conventional total knee arthroplasty, which uses an intramedullary rod (FIR) to orient the femoral prosthesis with respect to the FAA. The orientation and entry point of a FIR with a length of 200 mm are automatically determined from the FAA, as it has been shown that errors in these parameters may lead to malalignment of the mechanical axis. Moreover, the effect of partially scanning the leg was investigated by creating reduced femur models and comparing the results with the full models. Precise measurements are obtained for 50 models by using a central and two outer parts, with lengths of 20 and 120 mm, which correspond to 58% of the mean femoral length. The deviations were less than 2 mm for the FAA, 2.8 mm for the FAA endpoints and 0.7°and 1.3 mm for the FIR orientation and entry point. The computer‐based techniques might eventually be used for preoperative planning of total knee arthroplasty. Copyright © 2011 John Wiley & Sons, Ltd.
- 14 November 2011
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 28 (1) , 158-169
Automated extraction of the femoral anatomical axis for determining the intramedullary rod parameters in total knee arthroplasty
SUMMARY: The automated extraction of anatomical reference parameters may improve speed, precision and accuracy of surgical procedures. In this study, an automated method for extracting the femoral anatomical axis (FAA) from a 3D surface mesh, based on geometrical entity fitting, is presented. This was applied to conventional total knee arthroplasty, which uses an intramedullary rod (FIR) to orient the femoral prosthesis with respect to the FAA. The orientation and entry point of a FIR with a length of 200 mm are automatically determined from the FAA, as it has been shown that errors in these parameters may lead to malalignment of the mechanical axis. Moreover, the effect of partially scanning the leg was investigated by creating reduced femur models and comparing the results with the full models. Precise measurements are obtained for 50 models by using a central and two outer parts, with lengths of 20 and 120 mm, which correspond to 58% of the mean femoral length. The deviations were less than 2 mm for the FAA, 2.8 mm for the FAA endpoints and 0.7°and 1.3 mm for the FIR orientation and entry point. The computer‐based techniques might eventually be used for preoperative planning of total knee arthroplasty. Copyright © 2011 John Wiley & Sons, Ltd.
- 1 February 2010
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 13 (1) , 59-69
A new method for improved standardisation in three-dimensional computed tomography cephalometry
Interest for three-dimensional computed tomography cephalometry has risen over the last two decades. Current methods commonly rely on the examiner to manually point-pick the landmarks and/or orientate the skull. In this study, a new approach is presented, in which landmarks are calculated after selection of the landmark region on a triangular model and in which the skull is automatically orientated in a standardised way. Two examiners each performed five analyses on three skull models. Landmark reproducibility was tested by calculating the standard deviation for each observer and the difference between the mean values of both observers. The variation can be limited to 0.1 mm for most landmarks. However, some landmarks perform less well and require further investigation. With the proposed reference system, a symmetrical orientation of the skulls is obtained. The presented methods contribute to standardisation in cephalometry and could therefore allow improved comparison of patient data.
- 1 February 2010
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 13 (1) , 59-69
A new method for improved standardisation in three-dimensional computed tomography cephalometry
Interest for three-dimensional computed tomography cephalometry has risen over the last two decades. Current methods commonly rely on the examiner to manually point-pick the landmarks and/or orientate the skull. In this study, a new approach is presented, in which landmarks are calculated after selection of the landmark region on a triangular model and in which the skull is automatically orientated in a standardised way. Two examiners each performed five analyses on three skull models. Landmark reproducibility was tested by calculating the standard deviation for each observer and the difference between the mean values of both observers. The variation can be limited to 0.1 mm for most landmarks. However, some landmarks perform less well and require further investigation. With the proposed reference system, a symmetrical orientation of the skulls is obtained. The presented methods contribute to standardisation in cephalometry and could therefore allow improved comparison of patient data.
- 1 January 2009
- Published by Springer Nature
- p. 1442-1445
3D cephalometry: a new approach for landmark identification and image orientation
- 1 January 2009
- Published by Springer Nature
- p. 1442-1445
3D cephalometry: a new approach for landmark identification and image orientation