Controlled laboratory experiments were conducted to demonstrate the use of passive samplers for soil vapor concentration monitoring. Five different passive samplers were studied (Radiello, SKC Ultra, Waterloo Membrane Sampler, ATD tubes and 3M OVM 3500). Ten different volatile organic compounds were used of varying classes (chlorinated ethanes, ethanes, and methanes, aliphatics and aromatics) and physical properties (vapor pressure, solubility and sorption). Samplers were exposed in randomized triplicates to concentrations of 1, 10 and 100 ppmv, with a relative humidity of ∼80%, a temperature of ∼24 °C, and a duration of 30 minutes in a chamber with a face velocity of about 5 cm min−1. Passive samplers are more commonly used for longer sample durations (e.g., 8 hour workday) and higher face velocities (>600 cm min−1), so testing to verify the performance for these conditions was needed. Summa canister samples were collected and analyzed by EPA Method TO-15 to establish a baseline for comparison for all the passive samplers. Low-uptake rate varieties of four of the samplers were also tested at 10 ppmv under two conditions; with 5 cm min−1 face velocity and stagnant conditions to assess whether low or near-zero face velocities would result in a low bias from the starvation effect. The results indicate that passive samplers can provide concentration measurements with accuracy (mostly within a factor of 2) and precision (RSD < 15%) comparable to conventional Summa canister samples and EPA Method TO-15 analysis. Some compounds are challenging for some passive samplers because of uncertainties in the uptake rates, or challenges with retention or recovery.Keywords
This publication has 13 references indexed in Scilit:
- Quantitative passive soil vapor sampling for VOCs- part 3: field experimentsEnvironmental Science: Processes & Impacts, 2014
- Quantitative passive soil vapor sampling for VOCs- part 1: theoryEnvironmental Science: Processes & Impacts, 2014
- Polydimethylsiloxane-based permeation passive air sampler. Part I: Calibration constants and their relation to retention indices of the analytesJournal of Chromatography A, 2011
- Polydimethylsiloxane-based permeation passive air sampler. Part II: Effect of temperature and humidity on the calibration constantsJournal of Chromatography A, 2010
- Field evaluation of thermal and chemical desorption BTEX radial diffusive sampler radiello ® compared with active (pumped) samplers for ambient air measurementsJournal of Environmental Monitoring, 2008
- Offshore Passive Soil Vapor Survey at a Contaminated Coastal SiteJournal of Environmental Engineering, 1998
- Experience in the Use of the NIOSH Diffusive Sampler Evaluation ProtocolAIHA Journal, 1996
- COMPARISON OF THE CHARCOAL TUBE AND A PASSIVE ORGANIC VAPOUR DOSIMETER AS SAMPLE COLLECTION DEVICES FOR THE MEASUREMENT OF EXPOSURE TO COMPONENTS OF GASOLINE VAPOURAnnals of Work Exposures and Health, 1994
- Measurement of volatile organic compounds in indoor air by a passive techniqueEnvironmental Technology, 1992
- Personal Monitoring Device for Gaseous ContaminantsAIHA Journal, 1973