Todd McAlary
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Todd McAlary has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Hester Groenevelt
Geosyntec Consultants, Guelph, Canada
7 shared publications- Tadeusz Górecki
Department of Chemistry, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
6 shared publications Brian Schumacher
United States Environmental Protection Agency, Las Vegas, USA
5 shared publicationsDerrick Crump
Cranfield University, Cranfield, UK
5 shared publicationsHeidi Hayes
Eurofins Air Toxics, Inc. (formerly Air Toxics Ltd.), Folsom, USA
5 shared publicationsPaolo Sacco
Fondazione Salvatore Maugeri, Padova, Italy
5 shared publications
Latest Publications
- 1 September 2021
- Published by Elsevier in Atmospheric Pollution Research
- Vol. 12 (9) , 101152
Field evaluation of a low-uptake VOC passive sampler suitable for long-term deployments
- 1 September 2021
- Published by Elsevier in Atmospheric Pollution Research
- Vol. 12 (9) , 101152
Field evaluation of a low-uptake VOC passive sampler suitable for long-term deployments
- 13 April 2021
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 41 (2) , 122-131
Simplified Approach for Calculating Building‐Specific Attenuation Factors and Vapor Intrusion Mitigation System Flux‐Based Radius of Influence
This article describes a simplified method to calculate a building‐specific subslab to indoor air attenuation factor using data collected during pressure‐field extension testing similar to industry standards for radon mitigation. It also describes a simplified method to calculate the radius of influence for a conventional suction point using a mass flux‐balance model. The analysis is based on three simple measurements: (1) the extraction flow rate, (2) cross‐slab applied vacuum at a radial distance of 3 feet, and (3) cross‐slab applied vacuum at a radial distance of 10 feet. The intent is to provide a practitioner with a rapid and useful screening‐level assessment of whether the benefits of reduced mitigation system costs warrant an investment in a more detailed mathematical analysis of the flow and vacuum data. In addition, this may also help a practitioner to make real‐time decisions regarding placement of communication test points during pressure‐field extension testing.
- 13 April 2021
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 41 (2) , 122-131
Simplified Approach for Calculating Building‐Specific Attenuation Factors and Vapor Intrusion Mitigation System Flux‐Based Radius of Influence
This article describes a simplified method to calculate a building‐specific subslab to indoor air attenuation factor using data collected during pressure‐field extension testing similar to industry standards for radon mitigation. It also describes a simplified method to calculate the radius of influence for a conventional suction point using a mass flux‐balance model. The analysis is based on three simple measurements: (1) the extraction flow rate, (2) cross‐slab applied vacuum at a radial distance of 3 feet, and (3) cross‐slab applied vacuum at a radial distance of 10 feet. The intent is to provide a practitioner with a rapid and useful screening‐level assessment of whether the benefits of reduced mitigation system costs warrant an investment in a more detailed mathematical analysis of the flow and vacuum data. In addition, this may also help a practitioner to make real‐time decisions regarding placement of communication test points during pressure‐field extension testing.
- 9 April 2021
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 41 (2) , 132-137
Subslab Depressurization Versus Subslab Ventilation: Insights from Recent Research
Many vapor intrusion (VI) mitigation systems involve some form of gas extraction from below the concrete floor slab of a building to create a static vacuum below the slab that meets or exceeds a value specified in a guidance document or standard. This also results in some degree of ventilation below the floor slab, which reduces vapor concentrations and achieves some level of mass removal of target chemicals. The relative contribution of vacuum and ventilation to protecting building occupants is generally not quantified. Recent research completed under ESTCP Project ER‐201322 yields some new insights using new lines of evidence. The results warrant changes in the guidance documents and standards of practice to promote and enable VI mitigation system designs that vary according to the transmissivity of the material below the floor slab and the rate of vertical leakance of indoor air across the floor slab and incorporate additional lines of evidence including the mass removal rate.
- 9 April 2021
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 41 (2) , 132-137
Subslab Depressurization Versus Subslab Ventilation: Insights from Recent Research
Many vapor intrusion (VI) mitigation systems involve some form of gas extraction from below the concrete floor slab of a building to create a static vacuum below the slab that meets or exceeds a value specified in a guidance document or standard. This also results in some degree of ventilation below the floor slab, which reduces vapor concentrations and achieves some level of mass removal of target chemicals. The relative contribution of vacuum and ventilation to protecting building occupants is generally not quantified. Recent research completed under ESTCP Project ER‐201322 yields some new insights using new lines of evidence. The results warrant changes in the guidance documents and standards of practice to promote and enable VI mitigation system designs that vary according to the transmissivity of the material below the floor slab and the rate of vertical leakance of indoor air across the floor slab and incorporate additional lines of evidence including the mass removal rate.
- 1 October 2020
- Published by Elsevier in Science of The Total Environment
- Vol. 740, 139988
Mathematical analysis and flux-based radius of influence for radon/VOC vapor intrusion mitigation systems
- 1 October 2020
- Published by Elsevier in Science of The Total Environment
- Vol. 740, 139988
Mathematical analysis and flux-based radius of influence for radon/VOC vapor intrusion mitigation systems
- 25 June 2018
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 52 (15) , 8438-8445
Fluid Flow Model for Predicting the Intrusion Rate of Subsurface Contaminant Vapors into Buildings
A new method is presented for calculating a building-specific subslab to indoor air attenuation factor for use in assessing subsurface vapor intrusion to indoor air. The technique includes: 1) subslab gas extraction with flow and vacuum measurements and mathematical modeling to characterize the bulk average vertical gas conductivity of the floor slab, 2) monitoring of the ambient pressure gradient across the floor slab with a micromanometer, 3) calculating the volumetric flow of soil gas into the building (Qsoil), and 4) dividing Qsoil by the building ventilation rate (Qbuilding) to calculate a building-specific attenuation factor. Sample calculations using order statistics from 121 individual tests are comparable to the U.S. EPA empirical attenuation factors for residential buildings and the U.S. Navy empirical attenuation factors for commercial/industrial buildings. A case study of a commercial building shows encouraging agreement between the attenuation factors calculated via this method and via conventional subslab and indoor air sampling.
- 25 June 2018
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 52 (15) , 8438-8445
Fluid Flow Model for Predicting the Intrusion Rate of Subsurface Contaminant Vapors into Buildings
A new method is presented for calculating a building-specific subslab to indoor air attenuation factor for use in assessing subsurface vapor intrusion to indoor air. The technique includes: 1) subslab gas extraction with flow and vacuum measurements and mathematical modeling to characterize the bulk average vertical gas conductivity of the floor slab, 2) monitoring of the ambient pressure gradient across the floor slab with a micromanometer, 3) calculating the volumetric flow of soil gas into the building (Qsoil), and 4) dividing Qsoil by the building ventilation rate (Qbuilding) to calculate a building-specific attenuation factor. Sample calculations using order statistics from 121 individual tests are comparable to the U.S. EPA empirical attenuation factors for residential buildings and the U.S. Navy empirical attenuation factors for commercial/industrial buildings. A case study of a commercial building shows encouraging agreement between the attenuation factors calculated via this method and via conventional subslab and indoor air sampling.
- Open Access
- 21 May 2015
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 17 (6) , 1190
Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types
Correction for ‘Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types’ by Todd McAlary et al., Environ. Sci.: Processes Impacts, 2015, 17, 896–905.
- 21 May 2015
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 17 (6) , 1190
Open AccessPassive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types
Correction for ‘Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types’ by Todd McAlary et al., Environ. Sci.: Processes Impacts, 2015, 17, 896–905.
- 24 March 2015
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 17 (5) , 896-905
Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types
This article describes laboratory testing of four passive diffusive samplers for assessing indoor air concentrations of volatile organic compounds (VOCs), including SKC Ultra II, Radiello®, Waterloo Membrane Sampler (WMS) and Automated Thermal Desorption (ATD) tubes with two different sorbents (Tenax TA and Carbopack B). The testing included 10 VOCs (including chlorinated ethenes, ethanes, and methanes, aromatic and aliphatic hydrocarbons), spanning a range of properties and including some compounds expected to pose challenges (naphthalene, methyl ethyl ketone). Tests were conducted at different temperatures (17 to 30 °C), relative humidities (30 to 90% RH), face velocities (0.014 to 0.41 m s−1), concentrations (1 to 100 parts per billion by volume [ppbv]) and sampling durations (1 to 7 days). The results show that all of the passive samplers provided data that met the success criteria (relative percent difference [RPD] ≤ 45% of active sample concentrations and coefficient of variation [COV] ≤ 30%) in the majority of cases, but some compounds were problematic for some samplers. The passive sampler uptake rates depend to varying degrees on the sampler, sorbent, target compounds and environmental conditions, so field calibration is advantageous for the highest levels of data quality.
- 24 March 2015
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 17 (5) , 896-905
Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types
This article describes laboratory testing of four passive diffusive samplers for assessing indoor air concentrations of volatile organic compounds (VOCs), including SKC Ultra II, Radiello®, Waterloo Membrane Sampler (WMS) and Automated Thermal Desorption (ATD) tubes with two different sorbents (Tenax TA and Carbopack B). The testing included 10 VOCs (including chlorinated ethenes, ethanes, and methanes, aromatic and aliphatic hydrocarbons), spanning a range of properties and including some compounds expected to pose challenges (naphthalene, methyl ethyl ketone). Tests were conducted at different temperatures (17 to 30 °C), relative humidities (30 to 90% RH), face velocities (0.014 to 0.41 m s−1), concentrations (1 to 100 parts per billion by volume [ppbv]) and sampling durations (1 to 7 days). The results show that all of the passive samplers provided data that met the success criteria (relative percent difference [RPD] ≤ 45% of active sample concentrations and coefficient of variation [COV] ≤ 30%) in the majority of cases, but some compounds were problematic for some samplers. The passive sampler uptake rates depend to varying degrees on the sampler, sorbent, target compounds and environmental conditions, so field calibration is advantageous for the highest levels of data quality.
- 21 March 2014
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 16 (5) , 1103-1111
Quantitative passive soil vapor sampling for VOCs – part 4: flow-through cell
This paper presents a controlled experiment comparing several quantitative passive samplers for monitoring concentrations of volatile organic compound (VOC) vapors in soil gas using a flow-through cell. This application is simpler than conventional active sampling using adsorptive tubes because the flow rate does not need to be precisely measured and controlled, which is advantageous because the permeability of subsurface materials affects the flow rate and the permeability of geologic materials is highly variable. Using passive samplers in a flow-through cell, the flow rate may not need to be known exactly, as long as it is sufficient to purge the cell in a reasonable time and minimize any negative bias attributable to the starvation effect. An experiment was performed in a 500 mL flow-through cell using a two-factor, one-half fraction fractional factorial test design with flow rates of 80, 670 and 930 mL min−1 and sample durations of 10, 15 and 20 minutes for each of five different passive samplers (passive Automatic Thermal Desorption Tube, Radiello®, SKC Ultra, Waterloo Membrane Sampler™ and 3M™ OVM 3500). A Summa canister was collected coincident with each passive sampler and analyzed by EPA Method TO-15 to provide a baseline for comparison of the passive sampler concentrations. The passive sampler concentrations were within a factor of 2 of the Summa canister concentrations in 32 of 35 cases. Passive samples collected at the low flow rate and short duration showed low concentrations, which is likely attributable to insufficient purging of the cell after sampler placement.
- 21 March 2014
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 16 (5) , 1103-1111
Quantitative passive soil vapor sampling for VOCs – part 4: flow-through cell
This paper presents a controlled experiment comparing several quantitative passive samplers for monitoring concentrations of volatile organic compound (VOC) vapors in soil gas using a flow-through cell. This application is simpler than conventional active sampling using adsorptive tubes because the flow rate does not need to be precisely measured and controlled, which is advantageous because the permeability of subsurface materials affects the flow rate and the permeability of geologic materials is highly variable. Using passive samplers in a flow-through cell, the flow rate may not need to be known exactly, as long as it is sufficient to purge the cell in a reasonable time and minimize any negative bias attributable to the starvation effect. An experiment was performed in a 500 mL flow-through cell using a two-factor, one-half fraction fractional factorial test design with flow rates of 80, 670 and 930 mL min−1 and sample durations of 10, 15 and 20 minutes for each of five different passive samplers (passive Automatic Thermal Desorption Tube, Radiello®, SKC Ultra, Waterloo Membrane Sampler™ and 3M™ OVM 3500). A Summa canister was collected coincident with each passive sampler and analyzed by EPA Method TO-15 to provide a baseline for comparison of the passive sampler concentrations. The passive sampler concentrations were within a factor of 2 of the Summa canister concentrations in 32 of 35 cases. Passive samples collected at the low flow rate and short duration showed low concentrations, which is likely attributable to insufficient purging of the cell after sampler placement.
- Open Access
- 24 January 2014
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 16 (3) , 491-500
Quantitative passive soil vapor sampling for VOCs- part 2: laboratory experiments
Controlled laboratory experiments were conducted to demonstrate the use of passive samplers for soil vapor concentration monitoring. Five different passive samplers were studied (Radiello, SKC Ultra, Waterloo Membrane Sampler, ATD tubes and 3M OVM 3500). Ten different volatile organic compounds were used of varying classes (chlorinated ethanes, ethanes, and methanes, aliphatics and aromatics) and physical properties (vapor pressure, solubility and sorption). Samplers were exposed in randomized triplicates to concentrations of 1, 10 and 100 ppmv, with a relative humidity of ∼80%, a temperature of ∼24 °C, and a duration of 30 minutes in a chamber with a face velocity of about 5 cm min−1. Passive samplers are more commonly used for longer sample durations (e.g., 8 hour workday) and higher face velocities (>600 cm min−1), so testing to verify the performance for these conditions was needed. Summa canister samples were collected and analyzed by EPA Method TO-15 to establish a baseline for comparison for all the passive samplers. Low-uptake rate varieties of four of the samplers were also tested at 10 ppmv under two conditions; with 5 cm min−1 face velocity and stagnant conditions to assess whether low or near-zero face velocities would result in a low bias from the starvation effect. The results indicate that passive samplers can provide concentration measurements with accuracy (mostly within a factor of 2) and precision (RSD < 15%) comparable to conventional Summa canister samples and EPA Method TO-15 analysis. Some compounds are challenging for some passive samplers because of uncertainties in the uptake rates, or challenges with retention or recovery.
- 24 January 2014
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 16 (3) , 491-500
Open AccessQuantitative passive soil vapor sampling for VOCs- part 2: laboratory experiments
Controlled laboratory experiments were conducted to demonstrate the use of passive samplers for soil vapor concentration monitoring. Five different passive samplers were studied (Radiello, SKC Ultra, Waterloo Membrane Sampler, ATD tubes and 3M OVM 3500). Ten different volatile organic compounds were used of varying classes (chlorinated ethanes, ethanes, and methanes, aliphatics and aromatics) and physical properties (vapor pressure, solubility and sorption). Samplers were exposed in randomized triplicates to concentrations of 1, 10 and 100 ppmv, with a relative humidity of ∼80%, a temperature of ∼24 °C, and a duration of 30 minutes in a chamber with a face velocity of about 5 cm min−1. Passive samplers are more commonly used for longer sample durations (e.g., 8 hour workday) and higher face velocities (>600 cm min−1), so testing to verify the performance for these conditions was needed. Summa canister samples were collected and analyzed by EPA Method TO-15 to establish a baseline for comparison for all the passive samplers. Low-uptake rate varieties of four of the samplers were also tested at 10 ppmv under two conditions; with 5 cm min−1 face velocity and stagnant conditions to assess whether low or near-zero face velocities would result in a low bias from the starvation effect. The results indicate that passive samplers can provide concentration measurements with accuracy (mostly within a factor of 2) and precision (RSD < 15%) comparable to conventional Summa canister samples and EPA Method TO-15 analysis. Some compounds are challenging for some passive samplers because of uncertainties in the uptake rates, or challenges with retention or recovery.
- 21 January 2014
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 16 (3) , 501-510
Quantitative passive soil vapor sampling for VOCs- part 3: field experiments
Volatile organic compounds (VOCs) are commonly associated with contaminated land and may pose a risk to human health via subsurface vapor intrusion to indoor air. Soil vapor sampling is commonly used to assess the nature and extent of VOC contamination, but can be complicated because of the wide range of geologic material permeability and moisture content conditions that might be encountered, the wide variety of available sampling and analysis methods, and several potential causes of bias and variability, including leaks of atmospheric air, adsorption–desorption interactions, inconsistent sampling protocols and varying levels of experience among sampling personnel. Passive sampling onto adsorbent materials has been available as an alternative to conventional whole-gas sample collection for decades, but relationships between the mass sorbed with time and the soil vapor concentration have not been quantitatively established and the relative merits of various commercially available passive samplers for soil vapor concentration measurement is unknown. This paper presents the results of field experiments using several different passive samplers under a wide range of conditions. The results show that properly designed and deployed quantitative passive soil vapor samplers can be used to measure soil vapor concentrations with accuracy and precision comparable to conventional active soil vapor sampling (relative concentrations within a factor of 2 and RSD comparable to active sampling) where the uptake rate is low enough to minimize starvation and the exposure duration is not excessive for weakly retained compounds.
- 21 January 2014
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 16 (3) , 501-510
Quantitative passive soil vapor sampling for VOCs- part 3: field experiments
Volatile organic compounds (VOCs) are commonly associated with contaminated land and may pose a risk to human health via subsurface vapor intrusion to indoor air. Soil vapor sampling is commonly used to assess the nature and extent of VOC contamination, but can be complicated because of the wide range of geologic material permeability and moisture content conditions that might be encountered, the wide variety of available sampling and analysis methods, and several potential causes of bias and variability, including leaks of atmospheric air, adsorption–desorption interactions, inconsistent sampling protocols and varying levels of experience among sampling personnel. Passive sampling onto adsorbent materials has been available as an alternative to conventional whole-gas sample collection for decades, but relationships between the mass sorbed with time and the soil vapor concentration have not been quantitatively established and the relative merits of various commercially available passive samplers for soil vapor concentration measurement is unknown. This paper presents the results of field experiments using several different passive samplers under a wide range of conditions. The results show that properly designed and deployed quantitative passive soil vapor samplers can be used to measure soil vapor concentrations with accuracy and precision comparable to conventional active soil vapor sampling (relative concentrations within a factor of 2 and RSD comparable to active sampling) where the uptake rate is low enough to minimize starvation and the exposure duration is not excessive for weakly retained compounds.