Abstract
Purpose Provide a projection-based algorithm to solve the class of optimization problems encountered in intensity modulated proton therapy (IMPT). The algorithm can handle percentage dose-volume constraints that are usually found in such problems. Methods To seek a feasible solution, the automatic relaxation method was used to project the spot weight vector onto the interval defined by lower and upper bound target dose constraints. The obtained solution was optimized separately based on the objective of each OAR in addition to maximizing the minimum target dose using the bisection search method using a stopping criterion of 10 cGy. The combined weight was used in the CQ algorithm to solve the split feasibility problem but with a special projection technique due to the non-convexity of dose volume constraints. The algorithm was applied to four clinical IMPT cases (meningioma, prostate, tongue, and oropharynx) and compared to the corresponding treatment plans optimized in Eclipse. Results The treatment plans obtained, for the four cases, using the BCQ-ARM algorithm have dosimetric endpoints that are similar to their counterparts generated from Eclipse. The algorithm worked equally well with all cases, including the complex head and neck ones. The stopping criterion of 10 cGy results in making the generated plans slightly less optimal (ε–optimal) rather than optimal, but with the advantage of the possibility of generating a database of plans. Conclusions The application of the BCQ-ARM algorithm to different cases of IMPT plans with dose volume constraints was demonstrated. The algorithm is successful in generating plans that are dosimetrically equivalent to their corresponding Eclipse plans. Thus, it is suitable to generate optimized treatment plans in a clinically reasonable time frame. This article is protected by copyright. All rights reservedKeywords
This publication has 24 references indexed in Scilit:
- Convex feasibility modeling and projection methods for sparse signal recoveryJournal of Computational and Applied Mathematics, 2012
- Robust optimization of intensity modulated proton therapyMedical Physics, 2012
- A robust algorithm of intensity modulated proton therapy for critical tissue sparing and target coveragePhysics in Medicine & Biology, 2011
- A fast optimization algorithm for multicriteria intensity modulated proton therapy planningMedical Physics, 2010
- Comparing planning time, delivery time and plan quality for IMRT, RapidArc and tomotherapyJournal of Applied Clinical Medical Physics, 2009
- Bounds on the largest singular value of a matrix and the convergence of simultaneous and block‐iterative algorithms for sparse linear systemsInternational Transactions in Operational Research, 2009
- IMRT: a review and previewPhysics in Medicine & Biology, 2006
- Exploration of tradeoffs in intensity-modulated radiotherapyPhysics in Medicine & Biology, 2005
- The multiple-sets split feasibility problem and its applications for inverse problemsInverse Problems, 2005
- A computational solution of the inverse problem in radiation-therapy treatment planningApplied Mathematics and Computation, 1988