Sherif M. Gadoue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sherif M. Gadoue has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Dolla Toomeh
Department of Radiation Oncology University of Miami Miami Florida USA
3 shared publicationsBlake E. Schultze
Department of Electrical and Computer Engineering Baylor University Waco Texas USA
1 shared publication- Narayan Sahoo
Department of Radiation Physics The University of Texas MD Anderson Cancer Center Houston Texas USA
1 shared publication Reinhard W. Schulte
Department of Basic Science Division of Biomedical Engineering Sciences Loma Linda University Loma linda California USA
1 shared publication
Latest Publications
- Open Access
- 23 September 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (10) , e70266
A comparative study of clinically used fast Monte Carlo dose engines for proton therapy
Background: Several fast Monte Carlo (MC) codes have been implemented and used to simulate proton transport and calculate patient doses in proton therapy. The resulting dose is typically compared to full MC codes, rather than other fast MC codes. Purpose: The primary goal of this study was to compare the gamma pass rates (GPRs) of dose calculation from different fast MC codes to evaluate the accuracy of the computation and modeling among these codes. Methods: Two GPU codes and one CPU MC code were commissioned to model our clinical proton beamline at University of Texas MD Anderson Cancer Center. The GPU models use single 2D Gaussian models, whereas the CPU model uses a double 2D Gaussian model. For comparative evaluation, 70 cancer patients were randomly selected from our clinical practice, 10 from each of the following treatment sites: head and neck, brain, esophagus, lung, mediastinum, spine, and prostate. The calculated dose was compared with the dose from the verification plan created in the clinical treatment planning system (TPS) using 3D gamma analysis. Results: The accuracy of dose calculation for all fast MC codes compared very well with the calculation from the TPS for the examined patient plans. GPR for all treatment sites ranged from 96.29% to 99.99%. In general, the double Gaussian model pass rate surpassed the single Gaussian model rate despite a slight accuracy reduction for prostate cases. GPRs for the single Gaussian codes ranged from 96.29% to 99.34%, whereas the double Gaussian model achieved a range of 98.68% to 99.99%. Conclusion: All commissioned codes we examined demonstrated acceptable 3D GPR across all patients and treatment sites tested. Although the CPU MC code was commissioned using a double 2D Gaussian model, the single 2D Gaussian model used in the GPU codes proved to be sufficiently effective, yielding a high GPR.
- 23 September 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (10) , e70266
Open AccessA comparative study of clinically used fast Monte Carlo dose engines for proton therapy
Background: Several fast Monte Carlo (MC) codes have been implemented and used to simulate proton transport and calculate patient doses in proton therapy. The resulting dose is typically compared to full MC codes, rather than other fast MC codes. Purpose: The primary goal of this study was to compare the gamma pass rates (GPRs) of dose calculation from different fast MC codes to evaluate the accuracy of the computation and modeling among these codes. Methods: Two GPU codes and one CPU MC code were commissioned to model our clinical proton beamline at University of Texas MD Anderson Cancer Center. The GPU models use single 2D Gaussian models, whereas the CPU model uses a double 2D Gaussian model. For comparative evaluation, 70 cancer patients were randomly selected from our clinical practice, 10 from each of the following treatment sites: head and neck, brain, esophagus, lung, mediastinum, spine, and prostate. The calculated dose was compared with the dose from the verification plan created in the clinical treatment planning system (TPS) using 3D gamma analysis. Results: The accuracy of dose calculation for all fast MC codes compared very well with the calculation from the TPS for the examined patient plans. GPR for all treatment sites ranged from 96.29% to 99.99%. In general, the double Gaussian model pass rate surpassed the single Gaussian model rate despite a slight accuracy reduction for prostate cases. GPRs for the single Gaussian codes ranged from 96.29% to 99.34%, whereas the double Gaussian model achieved a range of 98.68% to 99.99%. Conclusion: All commissioned codes we examined demonstrated acceptable 3D GPR across all patients and treatment sites tested. Although the CPU MC code was commissioned using a double 2D Gaussian model, the single 2D Gaussian model used in the GPU codes proved to be sufficiently effective, yielding a high GPR.
- 1 February 2022
- Published by Wiley in Medical Physics
- Vol. 49 (4) , 2699-2708
A dose–volume constraint (DVC) projection‐based algorithm for IMPT inverse planning optimization
Purpose Provide a projection-based algorithm to solve the class of optimization problems encountered in intensity modulated proton therapy (IMPT). The algorithm can handle percentage dose-volume constraints that are usually found in such problems. Methods To seek a feasible solution, the automatic relaxation method was used to project the spot weight vector onto the interval defined by lower and upper bound target dose constraints. The obtained solution was optimized separately based on the objective of each OAR in addition to maximizing the minimum target dose using the bisection search method using a stopping criterion of 10 cGy. The combined weight was used in the CQ algorithm to solve the split feasibility problem but with a special projection technique due to the non-convexity of dose volume constraints. The algorithm was applied to four clinical IMPT cases (meningioma, prostate, tongue, and oropharynx) and compared to the corresponding treatment plans optimized in Eclipse. Results The treatment plans obtained, for the four cases, using the BCQ-ARM algorithm have dosimetric endpoints that are similar to their counterparts generated from Eclipse. The algorithm worked equally well with all cases, including the complex head and neck ones. The stopping criterion of 10 cGy results in making the generated plans slightly less optimal (ε–optimal) rather than optimal, but with the advantage of the possibility of generating a database of plans. Conclusions The application of the BCQ-ARM algorithm to different cases of IMPT plans with dose volume constraints was demonstrated. The algorithm is successful in generating plans that are dosimetrically equivalent to their corresponding Eclipse plans. Thus, it is suitable to generate optimized treatment plans in a clinically reasonable time frame. This article is protected by copyright. All rights reserved
- 1 February 2022
- Published by Wiley in Medical Physics
- Vol. 49 (4) , 2699-2708
A dose–volume constraint (DVC) projection‐based algorithm for IMPT inverse planning optimization
Purpose Provide a projection-based algorithm to solve the class of optimization problems encountered in intensity modulated proton therapy (IMPT). The algorithm can handle percentage dose-volume constraints that are usually found in such problems. Methods To seek a feasible solution, the automatic relaxation method was used to project the spot weight vector onto the interval defined by lower and upper bound target dose constraints. The obtained solution was optimized separately based on the objective of each OAR in addition to maximizing the minimum target dose using the bisection search method using a stopping criterion of 10 cGy. The combined weight was used in the CQ algorithm to solve the split feasibility problem but with a special projection technique due to the non-convexity of dose volume constraints. The algorithm was applied to four clinical IMPT cases (meningioma, prostate, tongue, and oropharynx) and compared to the corresponding treatment plans optimized in Eclipse. Results The treatment plans obtained, for the four cases, using the BCQ-ARM algorithm have dosimetric endpoints that are similar to their counterparts generated from Eclipse. The algorithm worked equally well with all cases, including the complex head and neck ones. The stopping criterion of 10 cGy results in making the generated plans slightly less optimal (ε–optimal) rather than optimal, but with the advantage of the possibility of generating a database of plans. Conclusions The application of the BCQ-ARM algorithm to different cases of IMPT plans with dose volume constraints was demonstrated. The algorithm is successful in generating plans that are dosimetrically equivalent to their corresponding Eclipse plans. Thus, it is suitable to generate optimized treatment plans in a clinically reasonable time frame. This article is protected by copyright. All rights reserved
- 1 April 2019
- Published by Elsevier in Physica Medica
- Vol. 60, 22-29
Enhancement of linear energy transfer in gold nanoparticles mediated radiation therapy
- 1 April 2019
- Published by Elsevier in Physica Medica
- Vol. 60, 22-29
Enhancement of linear energy transfer in gold nanoparticles mediated radiation therapy
- 1 April 2019
- Published by Elsevier in Physica Medica
- Vol. 60, 7-13
Radio-sensitization efficacy of gold nanoparticles in inhalational nanomedicine and the adverse effect of nano-detachment due to coating inactivation
- 1 April 2019
- Published by Elsevier in Physica Medica
- Vol. 60, 7-13
Radio-sensitization efficacy of gold nanoparticles in inhalational nanomedicine and the adverse effect of nano-detachment due to coating inactivation