Robotic Intracorporeal Palpation With a Miniature Force-Sensing Probe for Minimally Invasive Surgery
- 18 June 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Abstract
Intraoperative tissue palpation is crucial in surgical procedures to ensure operational safety and clinical outcomes. However, current robotic minimally invasive surgery (MIS) fundamentally decouples surgeons’ haptic perception from tissue interaction, posing substantial challenges for intracorporeal stiffness assessment. To address this limitation, we present an intracorporeal robotic palpation framework integrating our team’s recently developed vision-based multi-axis force sensing module. This miniature sensing module (φ5mm) enables real-time tissue interaction force measurement during endoscopic operations. The proposed system employs teleoperated robotic control with remote center of motion (RCM) constraints to ensure safe instrument manipulation. It continuously correlates tissue deformation data with contact forces to reconstruct spatial stiffness distributions. Through iterative palpation maneuvers, the system dynamically updates the stiffness map of target anatomical regions. Comprehensive validation experiments were conducted using ex-vivo chicken tissues under simulated MIS conditions, demonstrating: 1) The system’s capability to reconstruct heterogeneous tissue stiffness distributions by resolving contact forces and tissue deformation estimation; 2) Effective implementation of the proposed framework to MIS considering RCM constraint. These results substantiate the clinical viability of the miniature force-sensing module for robotic intracorporeal palpation and establish a paradigm for enhancing haptic feedback in MIS applications.Keywords
Funding Information
- Tyree IHealthE Ph.D. Top-Up Scholarship
- China Scholarship Council Ph.D. Scholarship
- Talent Recruitment Project of Guangdong (2021QN02Y839)
- Science and Technology Innovation Committee of Shenzhen (JCYJ20220818102408018, GXWD20231129103418001)
- Australian Research Council (DP250102489)
- University of New South Wales (UNSW) Engineering (PS69063)
This publication has 40 references indexed in Scilit:
- A Review on the Form and Complexity of Human–Robot Interaction in the Evolution of Autonomous SurgeryAdvanced Intelligent Systems, 2024
- State of the art in movement around a remote point: a review of remote center of motion in roboticsFrontiers of Mechanical Engineering, 2024
- Laparoscopic Trocars: Marketed Versus True Dimensions–A Descriptive StudyJournal of Minimally Invasive Gynecology, 2024
- Design and validation of a spatial two-limb 3R1T parallel manipulator with remote center-of-motionMechanism and Machine Theory, 2020
- Artificial palpation in robotic surgery using haptic feedbackSurgical Endoscopy, 2018
- Generalized Framework for Control of Redundant Manipulators in Robot-Assisted Minimally Invasive SurgeryIRBM, 2018
- Smallest enclosing disks (balls and ellipsoids)2017
- Reviewing the technological challenges associated with the development of a laparoscopic palpation deviceThe International Journal of Medical Robotics and Computer Assisted Surgery, 2012
- The value of haptic feedback in conventional and robot-assisted minimal invasive surgery and virtual reality training: a current reviewSurgical Endoscopy, 2009
- Complications of laparoscopic cholecystectomy: A national survey of 4,292 hospitals and an analysis of 77,604 casesThe American Journal of Surgery, 1993