Tiantian Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tiantian Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Jiaole Wang
School of Space and Earth Sciences, Beihang University, Beijing, China
2 shared publications Beiping Miao
1 shared publicationChao Zhang
1 shared publication- Chao Zhang
School of Robotics and Advanced Manufacture, Harbin Institute of Technology (Shenzhen), Shenzhen, China
1 shared publication Erli Lyu
1 shared publicationLiang Xue
1 shared publication
Latest Publications
- Open Access
- 15 October 2026
- Published by Elsevier in SSRN Electronic Journal
Confidence-aware Depth-guided Visual Servoing for Assistive Nasal Endoscopy
Current nasal endoscopic examinations rely heavily on manual manipulation, which can lead to unstable visualization and low operational efficiency in narrow and tortuous anatomical cavities. Image-guided assistive control can reduce the burden of continuous manual operation, but visual cues extracted from endoscopic images may become unreliable under blur, noise, and illumination variation. To address this issue, this study proposes a confidence-aware endoscopic visual servoing framework for assistive nasal examination. Monocular endoscopic images are used to estimate relative depth and extract navigation targets, while a multi-factor confidence evaluation module assesses visual reliability based on image clarity, illumination quality, gradient consistency, and temporal consistency. The confidence evaluation is incorporated into the control loop to adapt the insertion step size and trigger retreat under unreliable visual feedback. The framework was implemented on a hand-held concentric-tube robotic platform and evaluated through depth-confidence analysis, controlled passage experiments with five volunteers, and nasal phantom experiments. Results show that the proposed strategy improves trajectory smoothness, visual stability, and navigation efficiency compared with manual operation. It also provides clearer and smoother exploration than fixed-step depth-guided navigation without confidence regulation.
- 15 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessConfidence-aware Depth-guided Visual Servoing for Assistive Nasal Endoscopy
Current nasal endoscopic examinations rely heavily on manual manipulation, which can lead to unstable visualization and low operational efficiency in narrow and tortuous anatomical cavities. Image-guided assistive control can reduce the burden of continuous manual operation, but visual cues extracted from endoscopic images may become unreliable under blur, noise, and illumination variation. To address this issue, this study proposes a confidence-aware endoscopic visual servoing framework for assistive nasal examination. Monocular endoscopic images are used to estimate relative depth and extract navigation targets, while a multi-factor confidence evaluation module assesses visual reliability based on image clarity, illumination quality, gradient consistency, and temporal consistency. The confidence evaluation is incorporated into the control loop to adapt the insertion step size and trigger retreat under unreliable visual feedback. The framework was implemented on a hand-held concentric-tube robotic platform and evaluated through depth-confidence analysis, controlled passage experiments with five volunteers, and nasal phantom experiments. Results show that the proposed strategy improves trajectory smoothness, visual stability, and navigation efficiency compared with manual operation. It also provides clearer and smoother exploration than fixed-step depth-guided navigation without confidence regulation.
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Robotic Intracorporeal Palpation With a Miniature Force-Sensing Probe for Minimally Invasive Surgery
Intraoperative tissue palpation is crucial in surgical procedures to ensure operational safety and clinical outcomes. However, current robotic minimally invasive surgery (MIS) fundamentally decouples surgeons’ haptic perception from tissue interaction, posing substantial challenges for intracorporeal stiffness assessment. To address this limitation, we present an intracorporeal robotic palpation framework integrating our team’s recently developed vision-based multi-axis force sensing module. This miniature sensing module (φ5mm) enables real-time tissue interaction force measurement during endoscopic operations. The proposed system employs teleoperated robotic control with remote center of motion (RCM) constraints to ensure safe instrument manipulation. It continuously correlates tissue deformation data with contact forces to reconstruct spatial stiffness distributions. Through iterative palpation maneuvers, the system dynamically updates the stiffness map of target anatomical regions. Comprehensive validation experiments were conducted using ex-vivo chicken tissues under simulated MIS conditions, demonstrating: 1) The system’s capability to reconstruct heterogeneous tissue stiffness distributions by resolving contact forces and tissue deformation estimation; 2) Effective implementation of the proposed framework to MIS considering RCM constraint. These results substantiate the clinical viability of the miniature force-sensing module for robotic intracorporeal palpation and establish a paradigm for enhancing haptic feedback in MIS applications.
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Robotic Intracorporeal Palpation With a Miniature Force-Sensing Probe for Minimally Invasive Surgery
Intraoperative tissue palpation is crucial in surgical procedures to ensure operational safety and clinical outcomes. However, current robotic minimally invasive surgery (MIS) fundamentally decouples surgeons’ haptic perception from tissue interaction, posing substantial challenges for intracorporeal stiffness assessment. To address this limitation, we present an intracorporeal robotic palpation framework integrating our team’s recently developed vision-based multi-axis force sensing module. This miniature sensing module (φ5mm) enables real-time tissue interaction force measurement during endoscopic operations. The proposed system employs teleoperated robotic control with remote center of motion (RCM) constraints to ensure safe instrument manipulation. It continuously correlates tissue deformation data with contact forces to reconstruct spatial stiffness distributions. Through iterative palpation maneuvers, the system dynamically updates the stiffness map of target anatomical regions. Comprehensive validation experiments were conducted using ex-vivo chicken tissues under simulated MIS conditions, demonstrating: 1) The system’s capability to reconstruct heterogeneous tissue stiffness distributions by resolving contact forces and tissue deformation estimation; 2) Effective implementation of the proposed framework to MIS considering RCM constraint. These results substantiate the clinical viability of the miniature force-sensing module for robotic intracorporeal palpation and establish a paradigm for enhancing haptic feedback in MIS applications.