Axial Compressive Behaviours of Coal Gangue Concrete-Filled Circular Steel Tubular Stub Columns after Chloride Salt Corrosion
Open Access
Abstract
The axial compressive behaviours of coal gangue concrete-filled steel tube (GCFST) columns after chloride salt corrosion were investigated numerically. Numerical modelling was conducted through the static analysis method by finite element (FE) analysis. The failure mechanism, residual strength, and axial load–displacement curves were validated against tests of the coal gangue aggregate concrete-filled steel tube (GCFST) columns at room and natural aggregate concrete-filled steel tube (NCFST) columns after salt corrosion circumstance. According to the analysis on the stress distribution of the steel tube, the stress value of the steel tube decreased as the corrosion rate increased at the same characteristic point. A parametric analysis was carried out to determine the effect of crucial variation on residual strength. It indicated that material strength, the steel ratio, and the corrosion rate made a profound impact on the residual strength from the FE. The residual strength of the columns exposed to chloride salt was in negative correlation with the corrosion rate. The impact on the residual strength of the column was little, obvious by the replacement rate of the coal gangue. A simplified design formula for predicting the ultimate strength of GCFST columns after chloride salt corrosion exposure was proposed.Keywords
Funding Information
- Scientific Research Fund of Liaoning Provincial Education Department (JYTMS20230822)
This publication has 46 references indexed in Scilit:
- Localized Corrosion Damage Study and Strengthening Strategies on Orthogonal Concrete Filled Steel Tubular Column2023
- Damage Model of Steel Fiber-Reinforced Coal Gangue Concrete under Freeze–Thaw Cycles Based on Weibull DistributionMaterials, 2023
- Study on Degradation Law and the Equivalent Thickness Model of Steel Subjected to Sulfate CorrosionMaterials, 2023
- Behaviour of CFST Stub Columns Subjected to Pure CompressionInternational Journal of Steel Structures, 2022
- Life-cycle analysis of FRP-strengthened offshore CFST columns suffering from steel corrosionComposite Structures, 2021
- Application of Coal Gangue as a Coarse Aggregate in Green Concrete Production: A ReviewMaterials, 2021
- Axial Behaviour of Corroded CFST Columns Wrapped with GFRP Sheets—An Experimental Investigation2020
- Degradation of Axial Ultimate Load-Bearing Capacity of Circular Thin-Walled Concrete-Filled Steel Tubular Stub Columns after CorrosionMaterials, 2020
- Tests on axial strength of circle CFST stub columns under marine atmosphere in cold regionConstruction and Building Materials, 2020
- Effects of the variety and content of coal gangue coarse aggregate on the mechanical properties of concreteConstruction and Building Materials, 2019