OculusGraphy: Description and Time Domain Analysis of Full-Field Electroretinograms Database
Authors:
- 15 May 2023
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 64-67
Abstract
Electroretinography is an established electrophysiological technique for clinical investigation of visual health function. The test involves the non-invasive assessment of the retinal function using light stimulation. This study presents a comprehensive database of five types of signals, including Scotopic 2.0 ERG response, Photopic 2.0 ERG response, Maximum 2.0 ERG response, Photopic 2.0 EGR Flicker response and Scotopic 2.0 ERG Oscillatory Potentials. The database includes 1975 signals from 323 patients, consisting of both adults and children. This study seeks to evaluate and analyze the classical parameters of three of the five signals, specifically Scotopic 2.0 ERG response, Photopic 2.0 ERG response, and Maximum 2.0 ERG response, using time-domain analysis. Correlation analysis was conducted in order to gain insights into the potential relationship between a patient's age and the classical parameters. However, the results suggest little to no correlation between these factors. The database presented in this study will serve as a useful resource for further research in the field of electrophysiology. Future research in this area could explore the use of other advanced analysis methods, such as frequency and time-frequency domain analyses, in order to gain further insights into the nuances of these signals and to better differentiate between healthy patients and those with pathologies. Additionally, further research is needed to establish norms for pediatric signals in order to better understand retinal health in children.Keywords
This publication has 16 references indexed in Scilit:
- The effects of bandpass filtering on the oscillatory potentials of the electroretinogramDocumenta Ophthalmologica, 2019
- ISCEV Standard for clinical electro-oculography (2017 update)Documenta Ophthalmologica, 2017
- ISCEV standard for clinical visual evoked potentials: (2016 update)Documenta Ophthalmologica, 2016
- Electroretinography (A Review)Folia Veterinaria, 2016
- The rod-driven a-wave of the dark-adapted mammalian electroretinogramProgress in Retinal and Eye Research, 2014
- ISCEV standard for clinical pattern electroretinography (PERG): 2012 updateDocumenta Ophthalmologica, 2012
- Photopic ERGs in Patients with Optic Neuropathies: Comparison with Primate ERGs after Pharmacologic Blockade of Inner RetinaInvestigative Ophthalmology & Visual Science, 2004
- The Scotopic Threshold Response of the Dark‐Adapted Electroretinogram of the MouseThe Journal of Physiology, 2002
- B-wave of the electroretinogram. A reflection of ON bipolar cell activity.Journal of General Physiology, 1989
- The components of the retinal action potential in mammals and their relation to the discharge in the optic nerveThe Journal of Physiology, 1933