Abstract
This paper focused on a self‐developed microfluidic array system with microfabricated capillary array electrophoresis (μ‐CAE) chip for parallel chip electrophoresis of biomolecules. The microfluidic array layout consists of two common reservoirs coupled to four separation channels connected to sample injection channel on the soda‐lime glass substrate. The excitation scheme for distributing a 20 mW laser beam to separation channels in an array is achieved. Under the control of program, the sample injection and separation in multichannel can be achieved through six high‐voltage modules' output. A CCD camera was used to monitor electrophoretic separations simultaneously in four channels with LIF detection, and the electropherograms can be plotted directly without reconstruction by additional software. Parallel multichannel electrophoresis of series biomolecules including amino acids, proteins, and nucleic acids was performed on this system and the results showed fine reproducibility.Keywords
This publication has 27 references indexed in Scilit:
- A 768-lane microfabricated system for high-throughput DNA sequencingLab on a Chip, 2005
- High-throughput single-strand conformation polymorphism analysis on a microfabricated capillary array electrophoresis deviceElectrophoresis, 2005
- High-Performance Genetic Analysis on Microfabricated Capillary Array Electrophoresis Plastic Chips Fabricated by Injection MoldingAnalytical Chemistry, 2005
- Determination of SARS‐coronavirus by a microfluidic chip systemElectrophoresis, 2004
- Multichannel homogeneous immunoassay for detection of 2,4,6‐trinitrotoluene (TNT) using a microfabricated capillary array electrophoresis chipElectrophoresis, 2004
- Micro Total Analysis Systems. Recent DevelopmentsAnalytical Chemistry, 2004
- DNA separations in microfabricated devices with automated capillary sample introductionElectrophoresis, 2001
- Selective Involvement of Superoxide Anion, but Not Downstream Compounds Hydrogen Peroxide and Peroxynitrite, in Tumor Necrosis Factor-α-induced Apoptosis of Rat Mesangial CellsJournal of Biological Chemistry, 2000
- A transmission imaging spectrograph and microfabricated channel system for DNA analysisElectrophoresis, 1999
- Miniaturized total chemical analysis systems: A novel concept for chemical sensingSensors and Actuators B: Chemical, 1990