Zhicheng Long
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhicheng Long has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Bingcheng Lin
Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, China
4 shared publications Jianhua Qin
Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, P. R. China
3 shared publicationsZheng Shen
Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, P. R. China
3 shared publicationsAvelino Javer
Cavendish Laboratory, University of Cambridge, Cambridge CB3 0HE, UK
2 shared publicationsDapeng Wu
Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, P. R. China
2 shared publicationsDayu Liu
Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, P. R. China
2 shared publications
Latest Publications
- Open Access
- 14 June 2013
- Published by Springer Nature in Nature Communications
- Vol. 4 (1) , 3003
Short-time movement of E. coli chromosomal loci depends on coordinate and subcellular localization
In bacteria, chromosomal architecture shows strong spatial and temporal organization, and regulates key cellular functions, such as transcription. Tracking the motion of chromosomal loci at short timescales provides information related to both the physical state of the nucleo–protein complex and its local environment, independent of large-scale motions related to genome segregation. Here we investigate the short-time (0.1–10 s) dynamics of fluorescently labelled chromosomal loci in Escherichia coli at different growth rates. At these timescales, we observe for the first time a dependence of the loci’s apparent diffusion on both their subcellular localization and chromosomal coordinate, and we provide evidence that the properties of the chromosome are similar in the tested growth conditions. Our results indicate that either non-equilibrium fluctuations due to enzyme activity or the organization of the genome as a polymer–protein complex vary as a function of the distance from the origin of replication.
- 14 June 2013
- Published by Springer Nature in Nature Communications
- Vol. 4 (1) , 3003
Open AccessShort-time movement of E. coli chromosomal loci depends on coordinate and subcellular localization
In bacteria, chromosomal architecture shows strong spatial and temporal organization, and regulates key cellular functions, such as transcription. Tracking the motion of chromosomal loci at short timescales provides information related to both the physical state of the nucleo–protein complex and its local environment, independent of large-scale motions related to genome segregation. Here we investigate the short-time (0.1–10 s) dynamics of fluorescently labelled chromosomal loci in Escherichia coli at different growth rates. At these timescales, we observe for the first time a dependence of the loci’s apparent diffusion on both their subcellular localization and chromosomal coordinate, and we provide evidence that the properties of the chromosome are similar in the tested growth conditions. Our results indicate that either non-equilibrium fluctuations due to enzyme activity or the organization of the genome as a polymer–protein complex vary as a function of the distance from the origin of replication.
- 3 January 2013
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 13 (5) , 947-954
Microfluidic chemostat for measuring single cell dynamics in bacteria
We designed a microfluidic chemostat consisting of 600 sub-micron trapping/growth channels connected to two feeding channels. The microchemostat traps E. coli cells and forces them to grow in lines for over 50 generations. Excess cells, including the mother cells captured at the start of the process, are removed from both ends of the growth channels by the media flow. With the aid of time-lapse microscopy, we have monitored dynamic properties such as growth rate and GFP expression at the single-cell level for many generations while maintaining a population of bacteria of similar age. We also use the microchemostat to show how the population responds to dynamic changes in the environment. Since more than 100 individual bacterial cells are aligned and immobilized in a single field of view, the microchemostat is an ideal platform for high-throughput intracellular measurements. We demonstrate this capability by tracking with sub-diffraction resolution the movements of fluorescently tagged loci in more than one thousand cells on a single device. The device yields results comparable to conventional agar microscopy experiments with substantial increases in throughput and ease of analysis.
- 3 January 2013
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 13 (5) , 947-954
Microfluidic chemostat for measuring single cell dynamics in bacteria
We designed a microfluidic chemostat consisting of 600 sub-micron trapping/growth channels connected to two feeding channels. The microchemostat traps E. coli cells and forces them to grow in lines for over 50 generations. Excess cells, including the mother cells captured at the start of the process, are removed from both ends of the growth channels by the media flow. With the aid of time-lapse microscopy, we have monitored dynamic properties such as growth rate and GFP expression at the single-cell level for many generations while maintaining a population of bacteria of similar age. We also use the microchemostat to show how the population responds to dynamic changes in the environment. Since more than 100 individual bacterial cells are aligned and immobilized in a single field of view, the microchemostat is an ideal platform for high-throughput intracellular measurements. We demonstrate this capability by tracking with sub-diffraction resolution the movements of fluorescently tagged loci in more than one thousand cells on a single device. The device yields results comparable to conventional agar microscopy experiments with substantial increases in throughput and ease of analysis.
- 9 March 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (11) , 1567-1575
Fundamentals of magnet-actuated droplet manipulation on an open hydrophobic surface
We systematically investigate droplet movement, coalescence, and splitting on an open hydrophobic surface. These processes are actuated by magnetic beads internalized in an oil-coated aqueous droplet using an external magnet. Results are organized into an ‘operating diagram’ that describes regions of droplet stable motion, breakage, and release from the magnet. The results are explained theoretically with a simple model that balances magnetic, friction, and capillary-induced drag forces and includes the effects of particle type, droplet size, surrounding oil layer, surface tension, and viscosity. Finally, we discuss the implications of the results for the design of magnet-actuated droplet systems for applications such as nucleic acid purification, immunoassay and drug delivery.
- 9 March 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (11) , 1567-1575
Fundamentals of magnet-actuated droplet manipulation on an open hydrophobic surface
We systematically investigate droplet movement, coalescence, and splitting on an open hydrophobic surface. These processes are actuated by magnetic beads internalized in an oil-coated aqueous droplet using an external magnet. Results are organized into an ‘operating diagram’ that describes regions of droplet stable motion, breakage, and release from the magnet. The results are explained theoretically with a simple model that balances magnetic, friction, and capillary-induced drag forces and includes the effects of particle type, droplet size, surrounding oil layer, surface tension, and viscosity. Finally, we discuss the implications of the results for the design of magnet-actuated droplet systems for applications such as nucleic acid purification, immunoassay and drug delivery.
- 27 September 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (12) , 1819-1824
Integrated multilayer microfluidic device with a nanoporous membrane interconnect for online coupling of solid-phase extraction to microchip electrophoresis
An integrated microfluidic device was developed for online coupling of solid-phase extraction to microchip electrophoresis (chip SPE-CE). With a nanoporous membrane sandwiched between two PDMS substrates, SPE preconcentration and electrophoretic separation can be carried out in upper and lower fluidic layers, separately and sequentially. During the SPE process, the thin membrane can act as a fluid isolator to prevent intermixing between two fluidic channels. However, when a pulse voltage is applied, the membrane becomes a gateable interconnect so that a small plug of concentrated analytes can be online injected into the lower channel for subsequent separations. This multilayer design provides a universal solution to online SPE-CE hyphenation. Both electroosmotic flow and hydrodynamic pumps have been adopted for SPE operation. SPE was performed on a 2.5 mm long microcolumn, with two weirs on both sides to retain the C18-coated silica beads. Rhodamine 123 and FITC-labelled ephedrine were used to test the operational performance of the hyphenation system. High separation efficiency and thousand-fold signal enhancement were achieved.
- 27 September 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (12) , 1819-1824
Integrated multilayer microfluidic device with a nanoporous membrane interconnect for online coupling of solid-phase extraction to microchip electrophoresis
An integrated microfluidic device was developed for online coupling of solid-phase extraction to microchip electrophoresis (chip SPE-CE). With a nanoporous membrane sandwiched between two PDMS substrates, SPE preconcentration and electrophoretic separation can be carried out in upper and lower fluidic layers, separately and sequentially. During the SPE process, the thin membrane can act as a fluid isolator to prevent intermixing between two fluidic channels. However, when a pulse voltage is applied, the membrane becomes a gateable interconnect so that a small plug of concentrated analytes can be online injected into the lower channel for subsequent separations. This multilayer design provides a universal solution to online SPE-CE hyphenation. Both electroosmotic flow and hydrodynamic pumps have been adopted for SPE operation. SPE was performed on a 2.5 mm long microcolumn, with two weirs on both sides to retain the C18-coated silica beads. Rhodamine 123 and FITC-labelled ephedrine were used to test the operational performance of the hyphenation system. High separation efficiency and thousand-fold signal enhancement were achieved.
- 7 December 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (24) , 4927-4934
Integration of nanoporous membranes for sample filtration/preconcentration in microchip electrophoresis
Microfluidic devices integrating membrane‐based sample preparation with electrophoretic separation are demonstrated. These multilayer devices consist of 10 nm pore diameter membranes sandwiched between two layers of PDMS substrates with embedded microchannels. Because of the membrane isolation, material exchange between two fluidic layers can be precisely controlled by applied voltages. More importantly, since only small molecules can pass through the nanopores, the integrated membrane can serve as a filter or a concentrator prior to microchip electrophoresis under different design and operation modes. As a filter, they can be used for separation and selective injection of small analytes from sample matrix. This has been effectively applied in rapid determination of reduced glutathione in human plasma and red blood cells without any off‐chip deproteinization procedure. Alternatively, in the concentrator mode, they can be used for online purification and preconcentration of macromolecules, which was illustrated by removing primers and preconcentrating the product DNA from a PCR product mixture.
- 7 December 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (24) , 4927-4934
Integration of nanoporous membranes for sample filtration/preconcentration in microchip electrophoresis
Microfluidic devices integrating membrane‐based sample preparation with electrophoretic separation are demonstrated. These multilayer devices consist of 10 nm pore diameter membranes sandwiched between two layers of PDMS substrates with embedded microchannels. Because of the membrane isolation, material exchange between two fluidic layers can be precisely controlled by applied voltages. More importantly, since only small molecules can pass through the nanopores, the integrated membrane can serve as a filter or a concentrator prior to microchip electrophoresis under different design and operation modes. As a filter, they can be used for separation and selective injection of small analytes from sample matrix. This has been effectively applied in rapid determination of reduced glutathione in human plasma and red blood cells without any off‐chip deproteinization procedure. Alternatively, in the concentrator mode, they can be used for online purification and preconcentration of macromolecules, which was illustrated by removing primers and preconcentrating the product DNA from a PCR product mixture.
- 21 November 2006
- Published by Elsevier in Journal of Chromatography B
- Vol. 844 (1) , 32-38
Isotachophoresis preconcentration integrated microfluidic chip for highly sensitive genotyping of the hepatitis B virus
- 21 November 2006
- Published by Elsevier in Journal of Chromatography B
- Vol. 844 (1) , 32-38
Isotachophoresis preconcentration integrated microfluidic chip for highly sensitive genotyping of the hepatitis B virus
- 16 November 2006
- Published by Wiley in Biotechnology Journal
- Vol. 1 (11) , 1225-1234
Recent advances of microfluidics in Mainland China
The history and current status of research on microfluidics in China is summarized in this review. The recent representative contributions in this field by Chinese scientists are cited. A perspective on some trends in future development of this field in China is presented.
- 16 November 2006
- Published by Wiley in Biotechnology Journal
- Vol. 1 (11) , 1225-1234
Recent advances of microfluidics in Mainland China
The history and current status of research on microfluidics in China is summarized in this review. The recent representative contributions in this field by Chinese scientists are cited. A perspective on some trends in future development of this field in China is presented.
- 2 August 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (17) , 6074-6080
Double-Cross Hydrostatic Pressure Sample Injection for Chip CE: Variable Sample Plug Volume and Minimum Number of Electrodes
A novel sample injection method for chip CE was presented. This injection method uses hydrostatic pressure, generated by emptying the sample waste reservoir, for sample loading and electrokinetic force for dispensing. The injection was performed on a double-cross microchip. One cross, created by the sample and separation channels, is used for formation of a sample plug. Another cross, formed by the sample and controlling channels, is used for plug control. By varying the electric field in the controlling channel, the sample plug volume can be linearly adjusted. Hydrostatic pressure takes advantage of its ease of generation on a microfluidic chip, without any electrode or external pressure pump, thus allowing a sample injection with a minimum number of electrodes. The potential of this injection method was demonstrated by a four-separation-channel chip CE system. In this system, parallel sample separation can be achieved with only two electrodes, which is otherwise impossible with conventional injection methods. Hydrostatic pressure maintains the sample composition during the sample loading, allowing the injection to be free of injection bias.
- 2 August 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (17) , 6074-6080
Double-Cross Hydrostatic Pressure Sample Injection for Chip CE: Variable Sample Plug Volume and Minimum Number of Electrodes
A novel sample injection method for chip CE was presented. This injection method uses hydrostatic pressure, generated by emptying the sample waste reservoir, for sample loading and electrokinetic force for dispensing. The injection was performed on a double-cross microchip. One cross, created by the sample and separation channels, is used for formation of a sample plug. Another cross, formed by the sample and controlling channels, is used for plug control. By varying the electric field in the controlling channel, the sample plug volume can be linearly adjusted. Hydrostatic pressure takes advantage of its ease of generation on a microfluidic chip, without any electrode or external pressure pump, thus allowing a sample injection with a minimum number of electrodes. The potential of this injection method was demonstrated by a four-separation-channel chip CE system. In this system, parallel sample separation can be achieved with only two electrodes, which is otherwise impossible with conventional injection methods. Hydrostatic pressure maintains the sample composition during the sample loading, allowing the injection to be free of injection bias.
- 7 March 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (5-6) , 1084-1092
Parallel analysis of biomolecules on a microfabricated capillary array chip
This paper focused on a self‐developed microfluidic array system with microfabricated capillary array electrophoresis (μ‐CAE) chip for parallel chip electrophoresis of biomolecules. The microfluidic array layout consists of two common reservoirs coupled to four separation channels connected to sample injection channel on the soda‐lime glass substrate. The excitation scheme for distributing a 20 mW laser beam to separation channels in an array is achieved. Under the control of program, the sample injection and separation in multichannel can be achieved through six high‐voltage modules' output. A CCD camera was used to monitor electrophoretic separations simultaneously in four channels with LIF detection, and the electropherograms can be plotted directly without reconstruction by additional software. Parallel multichannel electrophoresis of series biomolecules including amino acids, proteins, and nucleic acids was performed on this system and the results showed fine reproducibility.
- 7 March 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (5-6) , 1084-1092
Parallel analysis of biomolecules on a microfabricated capillary array chip
This paper focused on a self‐developed microfluidic array system with microfabricated capillary array electrophoresis (μ‐CAE) chip for parallel chip electrophoresis of biomolecules. The microfluidic array layout consists of two common reservoirs coupled to four separation channels connected to sample injection channel on the soda‐lime glass substrate. The excitation scheme for distributing a 20 mW laser beam to separation channels in an array is achieved. Under the control of program, the sample injection and separation in multichannel can be achieved through six high‐voltage modules' output. A CCD camera was used to monitor electrophoretic separations simultaneously in four channels with LIF detection, and the electropherograms can be plotted directly without reconstruction by additional software. Parallel multichannel electrophoresis of series biomolecules including amino acids, proteins, and nucleic acids was performed on this system and the results showed fine reproducibility.