Quantitative Ultrasound Imaging for Monitoring In Situ High-Intensity Focused Ultrasound Exposure
- 26 June 2014
- journal article
- research article
- Published by SAGE Publications in Ultrasonic Imaging
- Vol. 36 (4) , 239-255
Abstract
Quantitative ultrasound (QUS) imaging is hypothesized to map temperature elevations induced in tissue with high spatial and temporal resolution. To test this hypothesis, QUS techniques were examined to monitor high-intensity focused ultrasound (HIFU) exposure of tissue. In situ experiments were conducted on mammary adenocarcinoma tumors grown in rats and lesions were formed using a HIFU system. A thermocouple was inserted into the tumor to provide estimates of temperature at one location. Backscattered time-domain waveforms from the tissue during exposure were recorded using a clinical ultrasonic imaging system. Backscatter coefficients were estimated using a reference phantom technique. Two parameters were estimated from the backscatter coefficient (effective scatterer diameter (ESD) and effective acoustic concentration (EAC). The changes in the average parameters in the regions corresponding to the HIFU focus over time were correlated to the temperature readings from the thermocouple. The changes in the EAC parameter were consistently correlated to temperature during both heating and cooling of the tumors. The changes in the ESD did not have a consistent trend with temperature. The mean ESD and EAC before exposure were 120 ± 16 μm and 32 ± 3 dB/cm3, respectively, and changed to 144 ± 9 μm and 51 ± 7 dB/cm3, respectively, just before the last HIFU pulse was delivered to the tissue. After the tissue cooled down to 37°C, the mean ESD and EAC were 126 ± 8 μm and 35 ± 4 dB/cm3, respectively. Peak temperature in the range of 50-60°C was recorded by a thermocouple placed just behind the tumor. These results suggest that QUS techniques have the potential to be used for non-invasive monitoring of HIFU exposure.Keywords
This publication has 38 references indexed in Scilit:
- Ex vivo Study of Quantitative Ultrasound Parameters in Fatty Rabbit LiversUltrasound in Medicine & Biology, 2012
- Ultrasonic Assessment of Thermal Therapy in Rat LiverUltrasound in Medicine & Biology, 2012
- Temperature dependent ultrasonic characterization of biological mediaThe Journal of the Acoustical Society of America, 2011
- Real‐time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidneyNMR in Biomedicine, 2010
- Dynamic frame selection forin vivoultrasound temperature estimation during radiofrequency ablationPhysics in Medicine & Biology, 2010
- Non-invasive ultrasound-based temperature imaging for monitoring radiofrequency heating—phantom resultsPhysics in Medicine & Biology, 2007
- Magnetic resonance temperature imagingInternational Journal of Hyperthermia, 2005
- High-intensity focused ultrasound in the treatment of solid tumoursNature Reviews Cancer, 2005
- Noninvasive Estimation of Tissue Temperature Via High-Resolution Spectral Analysis TechniquesIEEE Transactions on Biomedical Engineering, 2005
- Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasoundIEEE Transactions on Biomedical Engineering, 1995