Comparison of performance of partial least squares regression, secured principal component regression, and modified secured principal component regression for determination of human serum albumin, γ-globulin and glucose in buffer solutions and in vivo blood glucose quantification by near-infrared spectroscopy
- 15 December 2006
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 387 (2) , 603-611
Abstract
The performances of three multivariate analysis methods—partial least squares (PLS) regression, secured principal component regression (sPCR) and modified secured principal component regression (msPCR)—are compared and tested for the determination of human serum albumin (HSA), γ-globulin, and glucose in phosphate buffer solutions and blood glucose quantification by near-infrared (NIR) spectroscopy. Results from the application of PLS, sPCR and msPCR are presented, showing that the three methods can determine the concentrations of HSA, γ-globulin and glucose in phosphate buffer solutions almost equally well provided that the prediction samples contain the same spectral information as the calibration samples. On the other hand, when some potential spectral features appear in new measurements, sPCR and msPCR outperform PLS significantly. The reason for this is that such spectral features are not included during calibration, which leads to a degradation in PLS prediction performance, while sPCR and msPCR can improve their predictions for the concentrations of the analytes by removing the uncalibrated features from the original spectra. This point is demonstrated by successfully applying sPCR and msPCR to in vivo blood glucose measurements. This work therefore shows that sPCR and msPCR may provide possible alternatives to PLS in cases where some uncalibrated spectral features are present in measurements used for concentration prediction.Keywords
This publication has 30 references indexed in Scilit:
- Near-infrared spectroscopic determination of human serum albumin, γ-globulin, and glucose in a control serum solution with searching combination moving window partial least squaresAnalytica Chimica Acta, 2004
- Pure Component Selectivity Analysis of Multivariate Calibration Models from Near-Infrared SpectraAnalytical Chemistry, 2004
- Simultaneous determination of human serum albumin, γ-globulin, and glucose in a phosphate buffer solution by near-infrared spectroscopy with moving window partial least-squares regressionThe Analyst, 2003
- Measurement of glucose and other analytes in undiluted human serum with near-infrared transmission spectroscopyAnalytica Chimica Acta, 1998
- Multivariate Determination of Human Serum Albumin and γ-Globulin in a Phosphate Buffer Solution by near Infrared SpectroscopyJournal of Near Infrared Spectroscopy, 1998
- Clinical Chemistry and near Infrared Spectroscopy: Multicomponent Assay for Human Plasma and its Evaluation for the Determination of Blood SubstratesJournal of Near Infrared Spectroscopy, 1998
- Enhancing calibration models for non-invasive near-infrared spectroscopical blood glucose determinationAnalytical and Bioanalytical Chemistry, 1997
- Genetics1995
- Near-infrared spectroscopic determination of serum total proteins, albumin, globulins, and ureaClinical Biochemistry, 1993
- Determination of physiological levels of glucose in an aqueous matrix with digitally filtered Fourier transform near-infrared spectraAnalytical Chemistry, 1990