Biomechanical effect of inclined implants in fixed prosthesis: strain and stress analysis
Open Access
- 13 August 2018
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 47 (4) , 237-243
Abstract
Introduction Implant inclinations can be corrected using mini abutments at different angulations. Objective To analyze the influence of external hexagon implants in different inclinations (3 levels) on the microstrain distribution generated around three implants. Method A geometric bone model was created through Rhinoceros CAD software (version 5.0 SR8, Mcneel North America, Seattle, WA, USA). Three implants (4.1 × 13 mm) were modeled and inserted inside the substrate at three different inclinations: 0º, 17º and 30º. Next, all groups received mini conical abutments, fixation screws and a simplified prosthesis. The final geometry was exported in STEP format to analysis software and all materials were considered homogeneous, isotropic and linearly elastic. An axial load (300N) was applied on the center of the prosthesis. An in vitro study was conducted with same conditions and groups for validating the tridimentional model. Result Stress was concentrated on the external area of the implants, in contact with the cortical bone and external hexagon. For the bone simulator, the strain increased in the peri-implant region according to the increase in the implant’s inclination. The difference between groups was significant (p = 0.000). The 30º group presented higher stress and strain concentration. Conclusion The microstrain and stress increase around implants directly proportional to the increase of the installation angle.Keywords
This publication has 19 references indexed in Scilit:
- Simulated bone remodeling around tilted dental implants in the anterior maxillaBiomechanics and Modeling in Mechanobiology, 2015
- The Influence of Interimplant Divergence on the Retention Characteristics of Locator Attachments, a Laboratory StudyJournal of Prosthodontics, 2014
- Use of Stress Analysis Methods to Evaluate the Biomechanics of Oral Rehabilitation With ImplantsJournal of Oral Implantology, 2014
- Microstrain Around Dental Implants Supporting Fixed Partial Prostheses Under Axial and Non–Axial Loading Conditions, In Vitro Strain Gauge AnalysisJournal of Craniofacial Surgery, 2013
- Stress analysis of a fixed implant-supported denture by the finite element method (FEM) when varying the number of teeth used as abutmentsJournal of Applied Oral Science, 2011
- Validation of an experimental polyurethane model for biomechanical studies on implant supported prosthesis - tension testsJournal of Applied Oral Science, 2011
- Solutions for Severely Angulated Implants in the Mandibular Overdenture: A Clinical ReportJournal of Prosthodontics, 2009
- Effect of abutment angulation on the strain on the bone around an implant in the anterior maxilla: A finite element studyThe Journal of Prosthetic Dentistry, 2007
- Finite element analysis of the influence of implant inclination, loading position, and load direction on stress distributionOdontology, 2003
- Comparison of Strains Transferred to a Bone Simulant Between As‐Cast and Postsoldered Implant Frameworks for a Five‐Implant‐Supported Fixed ProsthesisJournal of Prosthodontics, 1996