Metallic versus Non-Metallic Cerclage Cables System in Periprosthetic Hip Fracture Treatment: Single-Institution Experience at a Minimum 1-Year Follow-Up
Open Access
- 14 March 2022
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (6) , 1608
Abstract
Metallic cerclage cables are reliable and cost-effective internal fixation devices, which are largely used in surgical practice for the treatment of periprosthetic fractures. Nevertheless, complications connected with their use have been described in the literature, including the following: third-body generation, failure and consequent migration, fraying, allergies, and injury to the surgical team. The development of new materials offers alternatives to traditional metallic cables. This study compares the outcomes between two groups of patients affected by periprosthetic hip fractures, treated with titanium cables or with ultra-high-molecular-weight polyethylene (UHMWPe) iso-elastic cables. Our retrospective study aims to compare the clinical and radiological outcomes of titanium cables and UHMWPe iso-elastic cables, isolated or associated with dedicated plates, for the surgical treatment of periprosthetic fractures with stable implants. Two groups of 30 (group A—metallic cables) and 24 (group B—UHMWPe iso-elastic cables) patients have been surgically treated in our institution for hip periprosthetic fractures, between September 2017 and June 2020. The mean age of the patients was 81 years in group A and 80 years in group B. In our study, we included fractures classified as B1 or C, according to the Vancouver postoperative fractures classification; the patients were evaluated retrospectively at 1 year postoperatively, regarding the following: surgery time, blood loss, partial weight-bearing time, radiographical healing time, Harris hip score, and postoperative complications. Comparable outcomes were observed in patients from both groups. Group A showed a higher complication rate compared to group B, at 1 year postoperatively. Non-metallic nylon fiber and ultra-high-molecular-weight polyethylene (UHMWPe) cerclage cables could represent a reliable fixation device, ensuring comparable healing and complication rates with traditional titanium cerclage cables.Keywords
This publication has 32 references indexed in Scilit:
- Stainless steel wire versus FiberWire suture cerclage fixation to stabilize the humerus in total shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2014
- Osteoporosis in the European Union: medical management, epidemiology and economic burdenArchives of Osteoporosis, 2013
- Locking plate fixation for Vancouver B1 periprosthetic femoral fractures: a critical analysis of 135 casesJournal of Orthopaedic Science, 2013
- Braided cerclage wires: A biomechanical studyInjury, 2011
- Early Experience with a Novel Nonmetallic Cable in Reconstructive Hip SurgeryClinical Orthopaedics and Related Research, 2010
- Cemented Total Hip Replacement Cable Debris and Acetabular Construct DurabilityJournal of Bone and Joint Surgery, 2009
- Three Hundred and Twenty-one Periprosthetic Femoral FracturesJournal of Bone and Joint Surgery, 2006
- Prevalence of Primary and Revision Total Hip and Knee Arthroplasty in the United States From 1990 Through 2002Journal of Bone and Joint Surgery, 2005
- Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stemThe Journal of Arthroplasty, 2000
- Complications of a cable grip systemThe Journal of Arthroplasty, 1996