Can Moisture Buffer Performance be Estimated from Sorption Kinetics?
- 1 April 2006
- journal article
- Published by SAGE Publications in Journal of Building Physics
- Vol. 29 (4) , 281-299
Abstract
This article describes the research on the moisture buffering effect of building materials. A set of experiments on samples of current building materials are conducted under transient conditions of relative humidity (RH). The results obtained are then analyzed using kinetics models. The experimental settings are based on the moisture buffer value (MBV) test method currently under study by Nordic researchers. The main result from these tests is the MBV number that can be used to characterize the moisture buffer performance of a material or a system. The application of kinetics models to the experimental results is explored and several parameters are retrieved. A proposal for the use of these parameters is presented and its practical use is discussed.Keywords
This publication has 5 references indexed in Scilit:
- A Review of Humidity Buffering in the Interior SpacesJournal of Thermal Envelope and Building Science, 2004
- Prestudy on diffusion and transient condensation of water vapor in cement mortarCement and Concrete Research, 2002
- Pseudo-second order model for sorption processesProcess Biochemistry, 1999
- Humidity fixed points of binary saturated aqueous solutionsJournal of Research of the National Bureau of Standards Section A: Physics and Chemistry, 1977
- THE ADSORPTION OF GASES ON PLANE SURFACES OF GLASS, MICA AND PLATINUM.Journal of the American Chemical Society, 1918