Abstract
Background— A projection-based method of intrinsic cardiac gating in small-animal computed tomography imaging is presented. Methods and Results— In this method, which operates without external ECG monitoring, the gating reference signal is derived from the raw data of the computed tomography projections. After filtering, the derived gating reference signal is used to rearrange the projection images retrospectively into data sets representing different time points in the cardiac cycle during expiration. These time-stamped projection images are then used for tomographic reconstruction of different phases of the cardiac cycle. Intrinsic gating was evaluated in mice and rats and compared with extrinsic retrospective gating. An excellent agreement was achieved between ECG-derived gating signal and self-gating signal (coverage probability for a difference between the 2 measurements to be less than 5 ms was 89.2% in mice and 85.9% in rats). Functional parameters (ventricular volumes and ejection fraction) obtained from the intrinsic and the extrinsic data sets were not significantly different. The ease of use and reliability of intrinsic gating were demonstrated via a chemical stress test on 2 mice, in which the system performed flawlessly despite an increased heart rate. Because of intrinsic gating, the image quality was improved to the extent that even the coronary arteries of mice could be visualized in vivo despite a heart rate approaching 430 bpm. Feasibility of intrinsic gating for functional imaging and assessment of cardiac wall motion abnormalities was successfully tested in a mouse model of myocardial infarction. Conclusions— Our results demonstrate that self-gating using advanced software postprocessing of projection data promises to be a valuable tool for rodent computed tomography imaging and renders ECG gating with external electrodes superfluous.Keywords
This publication has 30 references indexed in Scilit:
- Intrinsic respiratory gating in small-animal CTEuropean Radiology, 2008
- Retrospective Motion Gating in Small Animal CT of Mice and RatsInvestigative Radiology, 2007
- Principles of Genetic Murine Models for Cardiac DiseaseCirculation, 2007
- Fast Retrospectively Gated Quantitative Four-Dimensional (4D) Cardiac Micro Computed Tomography Imaging of Free-Breathing MiceInvestigative Radiology, 2007
- Echocardiographic Assessment of Left Ventricular Mass in Neonatal and Adult Mice: Accuracy of Different Echocardiographic MethodsEchocardiography, 2006
- How to Perform an Accurate Assessment of Cardiac Function in Mice using High-Resolution Magnetic Resonance ImagingJournal of Cardiovascular Magnetic Resonance, 2006
- Prospective respiratory‐gated micro‐CT of free breathing rodentsMedical Physics, 2005
- Quantitative 3-Dimensional Echocardiography for Accurate and Rapid Cardiac Phenotype Characterization in MiceCirculation, 2004
- Self‐gated cardiac cine MRIMagnetic Resonance in Medicine, 2003
- Estimation of the heart respiratory motion with applications for cone beam computed tomography imaging: a simulation studyIEEE Transactions on Information Technology in Biomedicine, 2003