Adiabatic Performance Evaluation System for Waveguide Transmission Lines
- 7 September 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Abstract
In a temperature-controlled radio frequency (RF) power measurement system, there is a temperature difference between the system and the environment temperature. If a metal waveguide is used in the system, heat can reach the core of the system and affect the measurement. An adiabatic waveguide is utilized to reduce this heat flow. This paper introduces several WR10 rectangular waveguides that are used in the KRISS (Korea Research Institute of Standards and Science) microcalorimeter and an evaluation system that can measure the adiabatic performance of the waveguides via a thermostat. The basic concept and measurement setup for the evaluation system are briefly introduced, and the structure and the function of the waveguide heat source and heat sense modules of the thermostat are presented. The test results of the adiabatic performance of several WR10 rectangular waveguides are compared and the electromagnetic performance is presented. We also tested preliminary dielectric waveguides that have been co-studied with PTB (Physikalisch-Technische Bundesanstalt, Germany) recently. We propose an index to characterize the adiabatic performance of the waveguides. Based on the index results, we improve the adiabatic performance of our newly electroforming-processed adiabatic waveguide with a thick resin coating, which is forty times higher than that of the prototype KRISS microcalorimeter adiabatic waveguide. Finally, we fabricated and investigated dielectric waveguides that have a superb adiabatic property for the microcalorimeter application.Keywords
Funding Information
- Korea Research Institute of Standards and Science through Physical Metrology for National Strategic Needs (KRISS-2020-GP2020-0002)
This publication has 11 references indexed in Scilit:
- Medium Power Application of a Four-Port Reflectometer2018
- D-Band Waveguide Microcalorimeter for Millimeter-Wave Power Standard2018
- Precise Power Measurement With a Single-Mode Waveguide Calorimeter in the 220–330 GHz Frequency RangeIEEE Transactions on Instrumentation and Measurement, 2018
- Electromagnetic analysis of adiabatic coaxial line with applied air gap2017
- $V$ -Band Waveguide Microcalorimeter for Millimeter-Wave Power StandardsIEEE Transactions on Instrumentation and Measurement, 2017
- Development of a Type-N Coaxial Microcalorimeter for RF and Microwave Power Standards at KRISSIEEE Transactions on Instrumentation and Measurement, 2015
- Design and Performance Checks of the NPL Axial Heat Flow ApparatusInternational Journal of Thermophysics, 2014
- Adiabatic Design for a Coaxial Transmission LineIEEE Transactions on Instrumentation and Measurement, 2013
- A multi-sample 94GHz dissolution dynamic-nuclear-polarization systemJournal of Magnetic Resonance, 2012
- Radio Frequency and Microwave Power Measurement1990