Aditia Nur Bakti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Aditia Nur Bakti has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Dwi Mandaris
National Research and Innovation Agency
3 shared publications - Elvina Trivida
National Research and Innovation Agency
2 shared publications - Hutomo Wahyu Nugroho
National Research and Innovation Agency
2 shared publications - Wuwus Ardiatna
National Research and Innovation Agency
2 shared publications - Yoppy Yoppy
National Research and Innovation Agency
2 shared publications - Chihyun Cho
Electromagnetic Wave Metrology Group, Korea Research Institute of Standards and Science, Daejeon, South Korea
1 shared publication
Latest Publications
- Open Access
- 1 April 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (2) , 912-919
Electromagnetic interference risk from electrostatic discharge in infant incubators
This paper proposes an improved electromagnetic compatibility (EMC) risk analysis approach for medical equipment related to the effect of electrostatic discharge (ESD). This approach not only focuses on the risk of ESD from the susceptibility aspect but also investigates its conducted electromagnetic interference (EMI) characteristics. This study combines the standardized ESD test and conducted emission (CE) measurement simultaneously, applying it to the infant incubator and analyzing the spectrum of ESD current in the phase line in the time and frequency domain. The result shows that an ESD exposure caused current spikes with an average level of 13.8 A. Moreover, it also causes a broad spectral CE noise on the phase line of the infant incubator. Furthermore, the CE noise in the low-frequency range was also detected on the phase line during ESD exposure, indicating the risk of interference with other sensitive medical equipment connected to the same power network. The approach of proposed risk analysis in this study can be used to identify the risks of EMI due to ESD events in implementing the latest IEC 60601-1-2.
- 1 April 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (2) , 912-919
Open AccessElectromagnetic interference risk from electrostatic discharge in infant incubators
This paper proposes an improved electromagnetic compatibility (EMC) risk analysis approach for medical equipment related to the effect of electrostatic discharge (ESD). This approach not only focuses on the risk of ESD from the susceptibility aspect but also investigates its conducted electromagnetic interference (EMI) characteristics. This study combines the standardized ESD test and conducted emission (CE) measurement simultaneously, applying it to the infant incubator and analyzing the spectrum of ESD current in the phase line in the time and frequency domain. The result shows that an ESD exposure caused current spikes with an average level of 13.8 A. Moreover, it also causes a broad spectral CE noise on the phase line of the infant incubator. Furthermore, the CE noise in the low-frequency range was also detected on the phase line during ESD exposure, indicating the risk of interference with other sensitive medical equipment connected to the same power network. The approach of proposed risk analysis in this study can be used to identify the risks of EMI due to ESD events in implementing the latest IEC 60601-1-2.
- Open Access
- 1 February 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (1) , 166-174
Passive magnetic coil design for electromagnetic interference evaluation of axle counters
Measurement of magnetic fields near the railway tracks is crucial to ensure compatibility with the operation of axle counters. According to EN 50592 standard, the magnetic field is detected with a passive magnetic coil and an oscilloscope. From previous studies, in general, there has been no in-depth analysis of how the choice of coil winding parameters could affect the coil output voltage, which then affect the measurement sensitivity, in particular the coil design based on the standard and it is applicability for electromagnetic interference (EMI) evaluation of axle counters. Therefore, this paper will explore the design of a passive magnetic coil to obtain the optimum coil output voltage within the frequency range. Simulations showed that for 10-100 kHz and 100 kHz–1.3 MHz range, the optimum number of turns happened at 60-100 and 15-60 turns, respectively. Based on that, two example coils had been built. Simulations and measurements of their frequency response were in good agreement, with a deviation less than 1.0 dB.
- 1 February 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (1) , 166-174
Open AccessPassive magnetic coil design for electromagnetic interference evaluation of axle counters
Measurement of magnetic fields near the railway tracks is crucial to ensure compatibility with the operation of axle counters. According to EN 50592 standard, the magnetic field is detected with a passive magnetic coil and an oscilloscope. From previous studies, in general, there has been no in-depth analysis of how the choice of coil winding parameters could affect the coil output voltage, which then affect the measurement sensitivity, in particular the coil design based on the standard and it is applicability for electromagnetic interference (EMI) evaluation of axle counters. Therefore, this paper will explore the design of a passive magnetic coil to obtain the optimum coil output voltage within the frequency range. Simulations showed that for 10-100 kHz and 100 kHz–1.3 MHz range, the optimum number of turns happened at 60-100 and 15-60 turns, respectively. Based on that, two example coils had been built. Simulations and measurements of their frequency response were in good agreement, with a deviation less than 1.0 dB.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Adiabatic Performance Evaluation System for Waveguide Transmission Lines
In a temperature-controlled radio frequency (RF) power measurement system, there is a temperature difference between the system and the environment temperature. If a metal waveguide is used in the system, heat can reach the core of the system and affect the measurement. An adiabatic waveguide is utilized to reduce this heat flow. This paper introduces several WR10 rectangular waveguides that are used in the KRISS (Korea Research Institute of Standards and Science) microcalorimeter and an evaluation system that can measure the adiabatic performance of the waveguides via a thermostat. The basic concept and measurement setup for the evaluation system are briefly introduced, and the structure and the function of the waveguide heat source and heat sense modules of the thermostat are presented. The test results of the adiabatic performance of several WR10 rectangular waveguides are compared and the electromagnetic performance is presented. We also tested preliminary dielectric waveguides that have been co-studied with PTB (Physikalisch-Technische Bundesanstalt, Germany) recently. We propose an index to characterize the adiabatic performance of the waveguides. Based on the index results, we improve the adiabatic performance of our newly electroforming-processed adiabatic waveguide with a thick resin coating, which is forty times higher than that of the prototype KRISS microcalorimeter adiabatic waveguide. Finally, we fabricated and investigated dielectric waveguides that have a superb adiabatic property for the microcalorimeter application.
- 7 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Adiabatic Performance Evaluation System for Waveguide Transmission Lines
In a temperature-controlled radio frequency (RF) power measurement system, there is a temperature difference between the system and the environment temperature. If a metal waveguide is used in the system, heat can reach the core of the system and affect the measurement. An adiabatic waveguide is utilized to reduce this heat flow. This paper introduces several WR10 rectangular waveguides that are used in the KRISS (Korea Research Institute of Standards and Science) microcalorimeter and an evaluation system that can measure the adiabatic performance of the waveguides via a thermostat. The basic concept and measurement setup for the evaluation system are briefly introduced, and the structure and the function of the waveguide heat source and heat sense modules of the thermostat are presented. The test results of the adiabatic performance of several WR10 rectangular waveguides are compared and the electromagnetic performance is presented. We also tested preliminary dielectric waveguides that have been co-studied with PTB (Physikalisch-Technische Bundesanstalt, Germany) recently. We propose an index to characterize the adiabatic performance of the waveguides. Based on the index results, we improve the adiabatic performance of our newly electroforming-processed adiabatic waveguide with a thick resin coating, which is forty times higher than that of the prototype KRISS microcalorimeter adiabatic waveguide. Finally, we fabricated and investigated dielectric waveguides that have a superb adiabatic property for the microcalorimeter application.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 205-209
EMI risk analysis via dedicated evaluation of the susceptibility of medical devices
This paper focuses on the Electro-Magnetic Interference Risk Analysis of medical devices via the evaluation of their susceptibility. Medical devices for supporting patients' life are frequently applied in vulnerable environments such as hospitals and surgery rooms. The susceptibility analysis is based on a GTEM testing method derived from ANSI C63.18 and is applied to three different medical devices, namely ECG, patient monitor and an infusion pump. Specific interference signals are generated simulating telecommunication devices, more specifically Wi-Fi, GSM, and PMR. The results showed that especially the signals transmitted by the PMR may affect the performance of medical devices.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 205-209
EMI risk analysis via dedicated evaluation of the susceptibility of medical devices
This paper focuses on the Electro-Magnetic Interference Risk Analysis of medical devices via the evaluation of their susceptibility. Medical devices for supporting patients' life are frequently applied in vulnerable environments such as hospitals and surgery rooms. The susceptibility analysis is based on a GTEM testing method derived from ANSI C63.18 and is applied to three different medical devices, namely ECG, patient monitor and an infusion pump. Specific interference signals are generated simulating telecommunication devices, more specifically Wi-Fi, GSM, and PMR. The results showed that especially the signals transmitted by the PMR may affect the performance of medical devices.