Performance evaluation of the Sysmex pocH‐100iV Diff hematology analyzer for analysis of canine, feline, equine, and bovine blood
- 3 November 2011
- journal article
- research article
- Published by Wiley in Veterinary Clinical Pathology
- Vol. 40 (4) , 484-495
Abstract
Background: The Sysmex pocH‐100iV Diff is an impedance hematology analyzer recently introduced for point‐of‐care use in veterinary practices in Europe.Objective: The purpose of this study was to validate the pocH‐100iV Diff for analysis of blood samples from dogs, cats, horses, and cattle.Methods: Fresh EDTA‐blood samples from healthy and ill dogs (115), cats (94), horses (91), and cattle (78) were analyzed on the pocH‐100iV Diff and the Cell‐Dyn 3500. Results of the automated WBC differential counts were compared with the manual differential counts for 77 dogs, 65 cats, 40 horses, and 46 cattle. HCT were compared with PCVs obtained by microhematocrit centrifugation. Furthermore, precision, linearity, carry‐over, cell aging, and clinical relevance of the pocH‐100iV Diff results were assessed.Results: Most of the CBC results obtained by the pocH‐100iV Diff correlated well with those of the Cell‐Dyn 3500. Slightly low correlation was observed for canine MCV and hemoglobin concentration. Lymphocytes correlated well in horses and cattle, but less well in cats and dogs. The mixed cell population termed “OTHRS” (all granulocytes and monocytes for horses and cattle; neutrophils, monocytes, and basophils for cats and dogs) correlated well in all tested species. The instrument overestimated feline and canine eosinophils. In cats, platelet counts showed a strong negative bias.Conclusions: The overall performance of the pocH‐100iV Diff was excellent with the noted limitations. The automated differential count can be used as screening tool in conjunction with evaluation of a blood smear.Keywords
This publication has 20 references indexed in Scilit:
- Validation of the Sysmex XT‐2000iV hematology system for dogs, cats, and horses. I. Erythrocytes, platelets, and total leukocyte countsVeterinary Clinical Pathology, 2009
- Canine complete blood counts: a comparison of four in‐office instruments with the ADVIA 120 and manual differential countsVeterinary Clinical Pathology, 2009
- Aging stability of complete blood count and white blood cell differential parameters analyzed by Abbott CELL‐DYN Sapphire hematology analyzerInternational Journal of Laboratory Hematology, 2009
- Comparative clinical study of canine and feline total blood cell count results with seven in‐clinic and two commercial laboratory hematology analyzersVeterinary Clinical Pathology, 2008
- ICSH Guideline for worldwide point‐of‐care testing in haematology with special reference to the complete blood countInternational Journal of Laboratory Hematology, 2008
- Is the inherent imprecision of manual leukocyte differential counts acceptable for quantitative purposes?Veterinary Clinical Pathology, 2006
- Performance Evaluation of the Sysmex pocH-100i Automated Hematology AnalyzerLaboratory Hematology, 2005
- Evaluation of the Cell-Dyn 3500 Haematology Analyser for Bovine BloodComparative Clinical Pathology, 2002
- Current databases on biological variation: pros, cons and progressScandinavian Journal of Clinical and Laboratory Investigation, 1999
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986