The feasibility of robotic-assisted concomitant procedures during mitral valve operations
Open Access
- 23 October 2019
- journal article
- research article
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- Vol. 27 (4) , 478-483
Abstract
Background: In this study, we present our clinical experience and midterm results with the robotic-assisted concomitant procedures during mitral valve operations. Methods: Between March 2010 and February 2018, a total of 34 patients (8 males, 26 females; mean age 58.3 years; range, 34 to 78 years) who underwent robotic-assisted concomitant procedures during mitral valve surgery were retrospectively analyzed. Demographic characteristics of the patients, comorbidities, medical, and surgical histories, operative and laboratory results, electrocardiographic findings, postoperative intensive care unit and ward outcomes, and cardiac follow-up data were recorded. Atrial fibrillation-related medication use, stroke, or other thromboembolic events, and electrocardiographic reports in patients who underwent cryoablation were reviewed at three and 12 months after the operation. Results: A total of 76 robotic-assisted concomitant procedures were performed during mitral valve repair (n=11) or replacement (n=23) in 34 patients. These procedures were cryoablation (n=29), tricuspid valve repair (n=6), tricuspid valve replacement (n=2), left atrial appendage ligation (n=32), atrial septal defect and patent foramen ovale closure (n=5), and left atrial thrombectomy (n=2). The mean preoperative EuroSCORE values were 5.1±2.5. The mean duration of cardiopulmonary bypass and cross-clamp was 156±69.4 min and 101±42 min, respectively. Normal sinus rhythm was restored in 85% of the patients (24/28) after cryoablation and two patients (5.8%) had permanent pacemaker within a year during follow-up. There was one (2.9%) mortality in the early postoperative period due to hemorrhage related to the posterior left ventricular wall rupture. No blood product was used in 82.4% of the patients. One patient had a transient cerebral event and symptoms regressed completely within two months. Conclusion: Technological improvements and growing experience can decrease the suspects related to prolonged operational duration during robotic-assisted cardiac surgery. Concomitant procedures in addition to mitral valve operations can be performed with low complication rates in centers with experience of robotic surgery.Keywords
This publication has 11 references indexed in Scilit:
- Can complex mitral valve repair be performed with robotics? An institution’s experience utilizing a dedicated team approach in 500 patients†European Journal of Cardio-Thoracic Surgery, 2019
- Early results of robotically assisted mitral valve surgery: Analysis of the first 1000 casesThe Journal of Thoracic and Cardiovascular Surgery, 2018
- Robotic mitral valve replacement for rheumatic mitral diseaseAnnals of Cardiothoracic Surgery, 2017
- Robotically Assisted Repair of Partial Atrioventricular Canal DefectArtificial Organs, 2016
- The Expanding Role of Endoscopic Robotics in Mitral Valve Surgery: 1,257 Consecutive ProceduresThe Annals of Thoracic Surgery, 2015
- Conditional long-term survival following minimally invasive robotic mitral valve repair: a health services perspective2015
- Totally robotic atrial septal defect closure: 7-year single-institution experience and follow-upInteractive CardioVascular and Thoracic Surgery, 2014
- Concomitant Robotic Mitral and Tricuspid Valve Repair: Technique and Early ExperienceThe Annals of Thoracic Surgery, 2014
- 540 Consecutive Robotic Mitral Valve Repairs Including Concomitant Atrial Fibrillation CryoablationThe Annals of Thoracic Surgery, 2012
- A simple method for occlusion of both venae cavae in total cardiopulmonary bypass for robotic surgeryInteractive CardioVascular and Thoracic Surgery, 2011