Adiabatic Pulse Shape Influence on the Orientation Dependence of T 1 ρ Relaxation
- 25 March 2026
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 96 (2) , 611-622
Abstract
Purpose: To determine how adiabatic pulse shape influences the balance between magic angle effect (MAE) suppression and T 1 contamination in adiabatic T 1 ρ (Ad T 1 ρ ) mapping of ordered tissues. We systematically compared continuous‐wave (CW), hyperbolic‐secant 4 (HS4), and tan–tanh (TAN) preparations ex vivo, and evaluated the feasibility and repeatability of UTE‐Ad T 1 ρ mapping of the knee in vivo. Methods: UTE‐Ad T 1 ρ imaging was performed at 3 T. A bovine tendon was imaged at 0°, 55°, and 90° using CW, HS4 (3/6 ms), and TAN (3/6 ms) preparations at spin‐lock amplitudes of 500–1000 Hz. Five healthy volunteers and five patients with knee osteoarthritis were scanned. Data were fit with mono‐exponential (ME) and stretched‐exponential (SE) models. Intrasubject repeatability was assessed in healthy volunteers. Results: All preparations exhibited strong MAE (anisotropy ratios > 40%). TAN pulses consistently produced lower T 1 ρ values than HS4, indicating reduced T 1 contamination (ex vivo). ME‐ T 1 ρ remained orientation‐dependent across all pulses, whereas the SE parameter α was largely orientation‐independent (anisotropy ratio ≈2%–20%). TAN‐6 ms yielded T 1 ρ values most consistent with CW, while HS4‐6 ms produced substantially higher values in the knee joint. TAN‐6 ms (CV = 3.47%) and HS4‐6 ms (CV = 4.24%) demonstrated better repeatability than CW (CV = 7.24%). Conclusion: Adiabatic pulse shape strongly influences T 1 contamination, but none of the tested preparations eliminated MAE. TAN‐6 ms offered the best balance of reduced T 1 contamination and high repeatability. The near orientation‐independence of the SE parameter α suggests that it may serve as a more robust biomarker for highly ordered tissues.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (P41 EB017183)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (R01‐AR076328)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (R01‐AR076985)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (R01‐AR078308)
- National Institutes of Health (R01‐AR076328‐01A1)
- National Institutes of Health (R01‐AR076985‐01A1)
- National Institutes of Health (R01‐AR078308‐01A1)
This publication has 30 references indexed in Scilit:
- Whole knee joint mapping using a phase modulated UTE adiabatic T1ρ (PM‐UTE‐AdiabT1ρ) sequenceMagnetic Resonance in Medicine, 2023
- Balanced spin‐lock preparation for B1‐insensitive and B0‐insensitive quantification of the rotating frame relaxation time T1ρMagnetic Resonance in Medicine, 2020
- Convincing evidence for magic angle less‐sensitive quantitative T1ρ imaging of articular cartilage using the 3D ultrashort echo time cones adiabatic T1ρ (3D UTE cones‐AdiabT1ρ) sequenceMagnetic Resonance in Medicine, 2020
- 3D adiabatic T1ρ prepared ultrashort echo time cones sequence for whole knee imagingMagnetic Resonance in Medicine, 2018
- Validation and optimization of adiabatic T1ρ and T2ρ for quantitative imaging of articular cartilage at 3 TMagnetic Resonance in Medicine, 2016
- ISMRM workshop on fat–water separation: Insights, applications and progress in MRIMagnetic Resonance in Medicine, 2012
- Ultrashort TE T1ρ magic angle imagingMagnetic Resonance in Medicine, 2012
- Practical considerations in the use of polarized light microscopy in the analysis of the collagen network in articular cartilageMicroscopy Research and Technique, 2007
- The magic angle effect: A source of artifact, determinant of image contrast, and technique for imagingJournal of Magnetic Resonance Imaging, 2007
- T1ρ relaxation mapping in human osteoarthritis (OA) cartilage: Comparison of T1ρ with T2Journal of Magnetic Resonance Imaging, 2006