MKMahesh Bharath Keerthivasan

Mahesh Bharath Keerthivasan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mahesh Bharath Keerthivasan has a total of 85 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Motion-Related Repeat MRI Sequences in a High-Volume Health System: Operational Burden and Heterogeneous Diagnostic Benefit

    by Siddhant Dogra, Luke A. Ginocchio, Andrew C. McClelland, Matthew G. Young, Anthony Yang, Jason Wei, Sherif B. Elsherif, Nihal Patel, Wendy Huang, Hoi Cheung Zhang, et al.

  • Adiabatic Pulse Shape Influence on the Orientation Dependence of T 1 ρ Relaxation

    by Hector L. de Moura, Mahesh B. Keerthivasan, Jonathan Samuels, Marcelo V. W. Zibetti, Ravinder R. Regatte

    Purpose: To determine how adiabatic pulse shape influences the balance between magic angle effect (MAE) suppression and T 1 contamination in adiabatic T 1 ρ (Ad T 1 ρ ) mapping of ordered tissues. We systematically compared continuous‐wave (CW), hyperbolic‐secant 4 (HS4), and tan–tanh (TAN) preparations ex vivo, and evaluated the feasibility and repeatability of UTE‐Ad T 1 ρ mapping of the knee in vivo. Methods: UTE‐Ad T 1 ρ imaging was performed at 3 T. A bovine tendon was imaged at 0°, 55°, and 90° using CW, HS4 (3/6 ms), and TAN (3/6 ms) preparations at spin‐lock amplitudes of 500–1000 Hz. Five healthy volunteers and five patients with knee osteoarthritis were scanned. Data were fit with mono‐exponential (ME) and stretched‐exponential (SE) models. Intrasubject repeatability was assessed in healthy volunteers. Results: All preparations exhibited strong MAE (anisotropy ratios > 40%). TAN pulses consistently produced lower T 1 ρ values than HS4, indicating reduced T 1 contamination (ex vivo). ME‐ T 1 ρ remained orientation‐dependent across all pulses, whereas the SE parameter α was largely orientation‐independent (anisotropy ratio ≈2%–20%). TAN‐6 ms yielded T 1 ρ values most consistent with CW, while HS4‐6 ms produced substantially higher values in the knee joint. TAN‐6 ms (CV = 3.47%) and HS4‐6 ms (CV = 4.24%) demonstrated better repeatability than CW (CV = 7.24%). Conclusion: Adiabatic pulse shape strongly influences T 1 contamination, but none of the tested preparations eliminated MAE. TAN‐6 ms offered the best balance of reduced T 1 contamination and high repeatability. The near orientation‐independence of the SE parameter α suggests that it may serve as a more robust biomarker for highly ordered tissues.

  • Free-Breathing Hybrid Technique for Simultaneous Morphological and Quantitative Abdominal Imaging at 0.55 T

    by Mahesh B. Keerthivasan, Mary Bs Bruno, Eddy Solomon, Ryan Brown, Douglas Brantner, Kai Tobias Block, Hersh Chandarana

    Objectives: Quantitative proton density fat fraction (PDFF) and R2* estimation at lower field strengths, such as 0.55 T, is challenging due to lower signal-to-noise ratio, reduced fat water chemical shift, and increased T2* relaxation times. In this study, we propose a 3D hybrid technique for abdominal imaging at 0.55 T that enables the simultaneous acquisition of T2-weighted and T1-weighted images and quantification of fat fraction and R2* parameters. Materials and Methods: Numerical simulations were performed to optimize a prototype radial hybrid turbo spin echo gradient echo (TSE-GRE) acquisition scheme for improved PDFF and R2* estimation accuracy. Phantom imaging experiments with and without motion were performed to evaluate the sensitivity of the estimation to external motion. Eleven volunteers were imaged on a prototype 0.55 T system. Data were acquired using the proposed technique under free-breathing conditions, and motion-compensated reconstruction was performed using the respiratory signal from a pilot-tone device. Image contrast and estimation performance were compared with conventional acquisition schemes in vitro and in vivo. Results: Numerical simulations indicated R2* estimation accuracy was more sensitive to the choice of echo time compared with PDFF. Performing motion compensation reduced the mean error in R2* from 24 to 5 s -1 while the mean error in PDFF only reduced from 2.7% to 1.6%. The proposed technique generated T2-weighted images with comparable relative liver-spleen contrast as conventional imaging and there were no significant differences ( P >0.05) in the PDFF and R2* values estimated from the hybrid technique compared with conventional multi-echo GRE. Further, the free-breathing acquisition allowed improved slice coverage while overcoming breath-hold limitations of conventional acquisition schemes. Conclusions: The use of a hybrid TSE-GRE acquisition technique can allow simultaneous morphological and quantitative PDFF and R2* estimation at 0.55 T under free-breathing conditions.


  • B1+$ {\mathrm{B}}_1^{+} $ mapping near metallic implants using turbo spin echo pulse sequences

    by Iman Khodarahmi, Mary Bruno, Ran Schwarzkopf, Jan Fritz, Mahesh B. Keerthivasan

    Purpose: To propose a B 1 + mapping technique for imaging of body parts containing metal hardware, based on magnitude images acquired with turbo spin echo (TSE) pulse sequences. Theory and Methods: To encode the underlying B 1 + , multiple (two to four) TSE image sets with various excitation and refocusing flip angles were acquired. To this end, the acquired signal intensities were matched to a database of simulated signals which was generated by solving the Bloch equations taking into account the exact sequence parameters. The retrieved B 1 + values were validated against gradient‐recalled and spin echo dual angle methods, as well as a vendor‐provided TurboFLASH‐based mapping sequence, in gel phantoms and human subjects without and with metal implants. Results: In the absence of metal, phantom experiments demonstrated excellent agreement between the proposed technique using three or four flip angle sets and reference dual angle methods. In human subjects without metal implants, the proposed technique with three or four flip angle sets showed excellent correlation with the spin echo dual angle method. In the presence of metal, both phantoms and human subjects revealed a narrow range of B 1 + estimation with the reference techniques, whereas the proposed technique successfully resolved B 1 + near the metal. In select cases, the technique was implemented in conjunction with multispectral metal artifact reduction sequences and successfully applied for B 1 + shimming. Conclusion: The proposed technique enables resolution of B 1 + values in regions near metal hardware, overcoming susceptibility‐related and narrow‐range limitations of standard mapping techniques.


  • Optimized MR pulse sequence for high‐resolution brain 3D ‐T1ρ mapping with weighted spin‐lock acquisitions

    by Marcelo V. W. Zibetti, Rajiv Menon, Hector L. De Moura, Mahesh B. Keerthivasan, Ravinder R. Regatte

    Purpose: To implement and evaluate the feasibility of brain spin–lattice relaxation in the rotating frame (T1ρ) mapping using a novel optimized pulse sequence that incorporates weighted spin‐lock acquisitions, enabling high‐resolution three‐dimensional (3D) mapping. Methods: The optimized variable flip‐angle framework, previously proposed for knee T1ρ mapping, was enhanced by integrating weighted spin‐lock acquisitions. This strategic combination significantly boosts signal‐to‐noise ratio (SNR) while reducing data acquisition time, facilitating high‐resolution 3D‐T1ρ mapping of the brain. The proposed sequence was compared with magnetization‐prepared angle‐modulated partitioned k‐space spoiled gradient‐echo sequence snapshots (MAPSS). Results: The newly developed pulse sequence, tested for brain 3D‐T1ρ mapping for the first time, obtained maps in 4 min with quality comparable to a 20‐min MAPSS sequence. Specifically, the voxel‐wise median absolute percentage difference between these MR sequences at a resolution of 0.9 × 0.9 × 3 mm 3 is 13.1%. If high resolution is desired, with a voxel size of 0.5 × 0.5 × 3 mm 3 , the new sequence can acquire T1ρ maps in 8 min, surpassing a 20‐min (and resolution of 0.9 × 0.9 × 3 mm 3 ) MAPSS in SNR. The weighted spin‐lock acquisition combined with optimized variable flip angle improved the SNR over optimized variable flip angle alone by about 28%. Conclusion: Compared with the 20‐min MAPSS sequence for brain T1ρ mapping, the proposed learned high‐resolution 3D pulse sequence simultaneously achieved a 2.3‐fold improvement in effective (3.2‐fold nominal) spatial resolution, a 1.1‐fold improvement in SNR, and a 2.5‐fold reduction in scan time.


  • MR electrical properties mapping using vision transformers and canny edge detectors

    by Ilias I. Giannakopoulos, Giuseppe Carluccio, Mahesh B. Keerthivasan, Gregor Koerzdoerfer, Karthik Lakshmanan, Hector L. De Moura, José E. Cruz Serrallés, Riccardo Lattanzi

    Purpose: We developed a 3D vision transformer‐based neural network to reconstruct electrical properties (EP) from magnetic resonance measurements.Theory and Methods: Our network uses the magnitude of the transmit magnetic field of a birdcage coil, the associated transceive phase, and a Canny edge mask that identifies the object boundaries as inputs to compute the EP maps. We trained our network on a dataset of 10 000 synthetic tissue‐mimicking phantoms and fine‐tuned it on a dataset of 11 000 realistic head models. We assessed performance in‐distribution simulated data and out‐of‐distribution head models, with and without synthetic lesions. We further evaluated our network in experiments for an inhomogeneous phantom and a volunteer.Results: The conductivity and permittivity maps had an average peak normalized absolute error (PNAE) of 1.3% and 1.7% for the synthetic phantoms, respectively. For the realistic heads, the average PNAE for the conductivity and permittivity was 1.8% and 2.7%, respectively. The location of synthetic lesions was accurately identified, with reconstructed conductivity and permittivity values within 15% and 25% of the ground‐truth, respectively. The conductivity and permittivity for the phantom experiment yielded 2.7% and 2.1% average PNAEs with respect to probe‐measured values, respectively. The in vivo EP reconstruction truthfully preserved the subject's anatomy with average values over the entire head similar to the expected literature values.Conclusion: We introduced a new learning‐based approach for reconstructing EP from MR measurements obtained with a birdcage coil, marking an important step towards the development of clinically‐usable in vivo EP reconstruction protocols.


  • Performance of MR learned pulse sequences for 3D bi‐exponential, stretched‐exponential, and mono‐exponential T2 and T1ρ mapping of knee cartilage

    by Marcelo V. W. Zibetti, Hector L. De Moura, Anmol Monga, Mahesh B. Keerthivasan, Ravinder R. Regatte

    Purpose: To compare the performance of a learned magnetization‐prepared gradient echo (L‐MPGRE) sequence against a commonly used sequence for 3D T2 and T1ρ mapping of the knee joint, the magnetization‐prepared angle‐modulated partitioned k‐space spoiled gradient echo snapshots (MAPSS), on bi‐exponential (BE), stretched‐exponential (SE), and mono‐exponential (ME) relaxation models.Methods: We used a combined differentiable and non‐differentiable optimization to learn pulse sequence structure and its parameters for 3D T2 and T1ρ mapping of the knee joint using ME, SE, and BE models. The learned pulse sequence framework was used to improve quantitative accuracy and SNR and to reduce filtering effects. We compare the measured multi‐compartment values between the two sequences (n = 8), and their repeatability (n = 4) in healthy volunteers (n = 12 total).Results: The voxel‐wise median absolute percentage difference (MAPD) between the T2 and T1ρ maps obtained with each sequence was 18.6% and 19.9%, respectively. The T2 and T1ρ repeatability tests showed a MAPD of 18.5% and 19.1% for MAPSS, and 16.8% and 15.5% for L‐MPGRE. Bland–Altman region of interest (ROI)‐wise analysis shows that bias is small, close to −1.5%, and the coefficient of variation is around 5.5% when comparing ROIs from both sequences.Conclusion: The L‐MPGRE sequences can be used as a replacement for MAPSS for T2 and T1ρ mapping in the knee cartilage with advantages, achieving similar accuracy and 15% better repeatability in only half of its scan time.


  • Fat Suppression in Distal Extremity 3-T MRI Using Spectral Heterogeneity Adaptive Radiofrequency Pulses

    by Iman Khodarahmi, William R. Walter, Mary Bruno, Inge M. Brinkmann, Mahesh B. Keerthivasan, Venkata V. Chebrolu, Jan Fritz

    Patient-specific fat suppression using spectral heterogeneity adaptive radiofrequency pulses led to more homogeneous fat suppression in distal extremity MRI than conventional spectral fat suppression.


  • Open Access

    Preliminary Experience with Three Alternative Motion Sensors for 0.55 Tesla MR Imaging

    by Radhika Tibrewala, Douglas Brantner, Ryan Brown, Leanna Pancoast, Mahesh Keerthivasan, Mary Bruno, Kai Tobias Block, Bruno Madore, Daniel K. Sodickson, Christopher M. Collins

    Due to limitations in current motion tracking technologies and increasing interest in alternative sensors for motion tracking both inside and outside the MRI system, in this study we share our preliminary experience with three alternative sensors utilizing diverse technologies and interactions with tissue to monitor motion of the body surface, respiratory-related motion of major organs, and non-respiratory motion of deep-seated organs. These consist of (1) a Pilot-Tone RF transmitter combined with deep learning algorithms for tracking liver motion, (2) a single-channel ultrasound transducer with deep learning for monitoring bladder motion, and (3) a 3D Time-of-Flight camera for observing the motion of the anterior torso surface. Additionally, we demonstrate the capability of these sensors to simultaneously capture motion data outside the MRI environment, which is particularly relevant for procedures like radiation therapy, where motion status could be related to previously characterized cyclical anatomical data. Our findings indicate that the ultrasound sensor can track motion in deep-seated organs (bladder) as well as respiratory-related motion. The Time-of-Flight camera offers ease of interpretation and performs well in detecting surface motion (respiration). The Pilot-Tone demonstrates efficacy in tracking bulk respiratory motion and motion of major organs (liver). Simultaneous use of all three sensors could provide complementary motion information outside the MRI bore, providing potential value for motion tracking during position-sensitive treatments such as radiation therapy.


  • Optimizing variable flip angles in magnetization‐prepared gradient‐echo sequences for efficient 3D‐T1ρ mapping

    by Marcelo V. W. Zibetti, Hector L. De Moura, Mahesh B. Keerthivasan, Ravinder R. Regatte

    Purpose: To optimize the choice of the flip angles of magnetization‐prepared gradient‐echo sequences for improved accuracy, precision, and speed of 3D‐T1ρ mapping.Methods: We propose a new optimization approach for finding variable flip‐angle values that improve magnetization‐prepared gradient‐echo sequences used for 3D‐T1ρ mapping. This new approach can improve the accuracy and SNR, while reducing filtering effects. We demonstrate the concept in the three different versions of the magnetization‐prepared gradient‐echo sequences that are typically used for 3D‐T1ρ mapping and evaluate their performance in model agarose phantoms (n = 4) and healthy volunteers (n = 5) for knee joint imaging. We also tested the optimization with sequence parameters targeting faster acquisitions.Results: Our results show that optimized variable flip angle can improve the accuracy and the precision of the sequences, seen as a reduction of the mean of normalized absolute difference from about 5%–6% to 3%–4% in model phantoms and from 15%–16% to 11%–13% in the knee joint, and improving SNR from about 12–28 to 22–32 in agarose phantoms and about 7–14 to 13–17 in healthy volunteers. The optimization can also compensate for the loss in quality caused by making the sequence faster. This results in sequence configurations that acquire more data per unit of time with SNR and mean of normalized absolute difference measurements close to its slower versions.Conclusion: The optimization of the variable flip angle can be used to increase accuracy and precision, and to improve the speed of the typical imaging sequences used for quantitative 3D‐T1ρ mapping of the knee joint.