High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay
Open Access
- 20 July 2017
- journal article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 8 (8) , 3749-3762
Abstract
High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research high-sensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time-resolved detection of lanthanide fluorescence based on the time constants of the system and analyze the background and noise sources in a heterogeneous fluoroimmunoassay. We determine the limiting factors and their impact on the measurement performance. The suggested model can be generally applied to fluoroimmunoassays employing the dry-cup concept.Keywords
Funding Information
- Innovation Fund Denmark (4135-00118B)
This publication has 27 references indexed in Scilit:
- Serial Changes in Highly Sensitive Troponin I Assay and Early Diagnosis of Myocardial InfarctionJAMA, 2011
- Clinical performance of a new point-of-care cardiac troponin I assay compared to three laboratory troponin assaysClinica Chimica Acta, 2011
- Time‐resolved microscopy for imaging lanthanide luminescence in living cellsCytometry Part A, 2010
- Lanthanide Luminescence for Biomedical Analyses and ImagingChemical Reviews, 2010
- Practical time‐gated luminescence flow cytometry. II: Experimental evaluation using UV LED excitationCytometry Part A, 2007
- High intensity solid‐state UV source for time‐gated luminescence microscopyCytometry Part A, 2006
- Point-of-care immunotesting: Approaching the analytical performance of central laboratory methodsClinical Biochemistry, 2005
- Comparison of Cardiac Troponin I Immunoassays Variably Affected by Circulating AutoantibodiesClinical Chemistry, 2005
- Flash lamp-excited time-resolved fluorescence microscope suppresses autofluorescence in water concentrates to deliver an 11-fold increase in signal-to-noise ratioJournal of Biomedical Optics, 2004
- Time‐resolved fluorescence imaging of europium chelate label in immunohistochemistry and in situ hybridizationCytometry, 1992