In the previous article [Part 1 (8)], we have modelled alternative approaches to design of practical time‐gated luminescence (TGL) flow cytometry and examined the feasibility of employing a UV LED as the excitation source for the gated detection of europium dye labelled target in rapid flow stream. The continuous flow‐section approach is well suited for rare‐event cell counting in applications with a large number of nontarget autofluorescent particles. This article presents details of construction, operation and evaluation of a TGL flow cytometer using a UV LED excitation and a gated high‐gain channel photomultiplier tube (CPMT) for detection. The compact prototype TGL flow cytometer was constructed and optimised to operate at a TGL cycle rate of 6 kHz, with each cycle consisting of 100 μs LED pulsed excitation and ∼60 μs delay‐gated detection. The performance of the TGL flow cytometer was evaluated by enumerating 5.7 μm Eu3+ luminescence beads (having comparable intensity to europium‐chelate‐labeled Giardia cysts) in both autofluorescence‐rich environmental water concentrates and Sulforhodamine 101 (S101) solutions (broadband red fluorescence covering the spectral band of target signals), respectively.The prototype TGL flow cytometer was able to distinguish the target beads, and a maximum signal to background ratio of 38:1 was observed. Neither the environmental water concentrates nor S101 solution contributed to the background in the TGL detection phase. The counting efficiency of the TGL flow cytometer was typically >93% of values determined using conventional counting methods. © 2007 International Society for Analytical CytologyKeywords
This publication has 20 references indexed in Scilit:
- High intensity solid‐state UV source for time‐gated luminescence microscopyCytometry Part A, 2006
- Lanthanide-based luminescence probes and time-resolved luminescence bioassaysTrAC Trends in Analytical Chemistry, 2006
- Long-lived visible luminescence of UV LEDs and impact on LED excited time-resolved fluorescence applicationsJournal of Physics D: Applied Physics, 2006
- Development of functionalized fluorescent europium nanoparticles for biolabeling and time-resolved fluorometric applicationsJournal of Materials Chemistry, 2004
- Time‐resolved fluorescence microscopy using an improved europium chelate BHHST for the in situ detection of Cryptosporidium and GiardiaMicroscopy Research and Technique, 2004
- Preparation and Time-Resolved Fluorometric Application of Luminescent Europium NanoparticlesChemistry of Materials, 2004
- Novel fluorescent europium chelate-doped silica nanoparticles: preparation, characterization and time-resolved fluorometric applicationJournal of Materials Chemistry, 2004
- Combination of a Gated Phtotomultiplier Tube and a Phase Sensitive Detector for Use in an Intensive Pulsed Background Light SituationOptical Review, 2002
- A novel two-color flow cytometric assay for the detection ofCryptosporidium in environmental water samplesCytometry, 2000
- Use of ferro‐electric liquid crystal shutters for time‐resolved fluorescence microscopyCytometry, 1994