Repeatability of lens densitometry using Scheimpflug imaging
Authors:
- 1 May 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 40 (5) , 756-763
Abstract
To evaluate the repeatability of different lens densitometry analysis modes performed with Scheimpflug imaging using the Pentacam HR device. University eye hospital, Frankfurt am Main, Germany. Cross-sectional study. Eyes were analyzed under mydriasis during 2 examinations performed by the same examiner. Three single measurements were taken to assess lens densitometry via 3 modes as follows: peak (maximum), linear (vertical axis), and 3-dimensional (3-D). Measurements were also taken using 3 cylindrical reference blocks (P) with different diameters (2.0 mm, 4.0 mm, 6.00 mm) composing the whole lens depth. Repeatability was tested using Bland-Altman analysis. As statistical parameters, the coefficient of repeatability (CoR) and the relative repeatability (RR) were applied. The study analyzed 105 eyes. The CoR of the peak modus was 5.6 (RR, 29.8%); of the linear modus, 0.9 (RR, 8.8%); and of the 3-D modus, 0.36 (RR, 3.6%). The values of the P mode were lower, with a CoR between 0.19 and 0.30 (RR, 2.1%-3.3%). Lens densitometry using Scheimpflug imaging was highly repeatable. However, repeatability was dependent on the analysis mode used. Repeatability decreased with increasing opacification.Keywords
This publication has 9 references indexed in Scilit:
- Comprehensive assessment of nuclear and cortical backscatter metrics derived from rotating Scheimpflug imagesJournal of Cataract & Refractive Surgery, 2012
- Preoperative cataract grading by Scheimpflug imaging and effect on operative fluidics and phacoemulsification energyJournal of Cataract & Refractive Surgery, 2010
- Correlation of Nuclear Cataract Lens Density Using Scheimpflug Images with Lens Opacities Classification System III and Visual FunctionOphthalmology, 2009
- Repeatability and validity of lens densitometry measured with Scheimpflug imagingJournal of Cataract & Refractive Surgery, 2009
- Correlation of lens density measured using the Pentacam Scheimpflug system with the Lens Opacities Classification System III grading score and visual acuity in age-related nuclear cataractBritish Journal of Ophthalmology, 2008
- Comparison of Clinical and Digital Assessment of Nuclear Optical DensityOphthalmic Research, 1999
- Incidence and Progression of Nuclear Opacities in the Longitudinal Study of CataractOphthalmology, 1996
- A longitudinal study of cortical cataracts using retroillumination photographsCurrent Eye Research, 1996
- The Lens Opacities Classification System IIIArchives of Ophthalmology (1950), 1993