Critical performance and carbon dioxide emission analysis of low GWP refrigerants R431A, R432A and R433A as replacements to R22 applicable in room air conditioners: An analytical study
- 14 October 2025
- journal article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 239 (24) , 10175-10186
Abstract
The current investigation presents an extensive thermodynamic performance analysis and CO 2 emission analysis of R22 alternatives. Refrigerants such as R431A, R432A and R433A are considered as ozone friendly and low GWP R22 alternatives as per ASHRAE recommendations. Similarly, hydrofluorocarbon (HFC) refrigerant R407C is evaluated as a possible retrofit option for replacing R22. In this study, effect of various operating conditions like variation of superheating, subcooling, evaporation and condensing temperatures are considered in order to evaluate the performance of refrigerants. Moreover, comparative study of hydrocarbon (HC) blends (R431A, R432A and R433A) is made with HFC refrigerant R407C apart from hydrochlorofluorocarbon (HCFC) refrigerant R22. In this work, standard VCR cycle is taken for the thermodynamic analysis whereas CO 2 emissions are assessed by total equivalent warming index (TEWI). Results indicate that coefficient of performances (COPs) of R431A, R432A and R433A are higher in the range of 12.06%–15.98% when compared with R407C and they are relatively lower in the range of 2.73%–3.96% compared to R22. Compressor discharge temperatures of considered R22 alternatives are much lower than that of R407C and R22 by 1.62°C–17.05°C. The volumetric refrigeration capacities of R22 alternatives are higher in the range 0.11%–3.45% when compared with R407C and they are relatively lower in the range of 7.44%–10.82% compared to R22. TEWI of R407C is the highest among all the considered R22 alternatives and it is higher in the range of 13.28%–17.63%. Similarly, TEWIs of R22 alternatives are lower in the range of 2.48%–17.56% when compared to both R407C and R22. The study exhibited that overall performance of R22 alternatives (R431A, R432A and R433A) is better than R407C and R22.Keywords
This publication has 23 references indexed in Scilit:
- Energetic, economic and environmental (3E) analysis of R290, R454C and R465A for drop-in split type air conditioning running on R22Case Studies in Thermal Engineering, 2025
- Assessment of total equivalent warming impact (TEWI) of alternative refrigerants for retrofit of R22 in single split air conditioning systemJournal of Building Engineering, 2024
- Investigation on thermodynamic performance analysis and environmental effects of various new refrigerants used in air conditionersEnvironmental Science and Pollution Research, 2020
- Experimental performance of an R-22-based refrigeration system for use with R-1270, R-438A, R-404A and R-134aInternational Journal of Refrigeration, 2017
- Refrigeration Systems and Applications2017
- A ‘drop-in’ refrigerant R431A for replacing HCFC22 in residential air-conditioners and heat pumpsEnergy Conversion and Management, 2009
- Experimental performance of R432A to replace R22 in residential air-conditioners and heat pumpsApplied Thermal Engineering, 2009
- Theoretical analysis of a vapour compression refrigeration system with R502, R404A and R507AInternational Journal of Refrigeration, 2008
- Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumpsApplied Energy, 2008
- Cycle performance study on R32/R125/R161 as an alternative refrigerant to R407CApplied Thermal Engineering, 2007