Sharmas Vali Shaik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sharmas Vali Shaik has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Saboor Shaik
School of Mechanical Engineering, Vellore Institute of Technology, Vellore, India
3 shared publications Ashok Babu
National Institute of Technology Karnataka Surathkal, Mechanical Engineering Department, Mangalore-575025, India
2 shared publicationsKiran Kumar Gorantla
Department of Humanities and Basic Sciences, Aditya University, Surampalem, Andhra Pradesh, India
2 shared publications- Syed Sameer
Karnataka State Council for Science and Technology (KSCST), Indian Institute of Science Campus, Bengaluru, India
2 shared publications Talanki Puttaranga Setty
National Institute of Technology Karnataka Surathkal, Mechanical Engineering Department, Mangalore-575025, India
2 shared publicationsTp Ashok Babu
Department of Mechanical Engineering, National Institute of Technology Karnataka, Mangalore, India
2 shared publications
Latest Publications
- 14 October 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 239 (24) , 10175-10186
Critical performance and carbon dioxide emission analysis of low GWP refrigerants R431A, R432A and R433A as replacements to R22 applicable in room air conditioners: An analytical study
The current investigation presents an extensive thermodynamic performance analysis and CO 2 emission analysis of R22 alternatives. Refrigerants such as R431A, R432A and R433A are considered as ozone friendly and low GWP R22 alternatives as per ASHRAE recommendations. Similarly, hydrofluorocarbon (HFC) refrigerant R407C is evaluated as a possible retrofit option for replacing R22. In this study, effect of various operating conditions like variation of superheating, subcooling, evaporation and condensing temperatures are considered in order to evaluate the performance of refrigerants. Moreover, comparative study of hydrocarbon (HC) blends (R431A, R432A and R433A) is made with HFC refrigerant R407C apart from hydrochlorofluorocarbon (HCFC) refrigerant R22. In this work, standard VCR cycle is taken for the thermodynamic analysis whereas CO 2 emissions are assessed by total equivalent warming index (TEWI). Results indicate that coefficient of performances (COPs) of R431A, R432A and R433A are higher in the range of 12.06%–15.98% when compared with R407C and they are relatively lower in the range of 2.73%–3.96% compared to R22. Compressor discharge temperatures of considered R22 alternatives are much lower than that of R407C and R22 by 1.62°C–17.05°C. The volumetric refrigeration capacities of R22 alternatives are higher in the range 0.11%–3.45% when compared with R407C and they are relatively lower in the range of 7.44%–10.82% compared to R22. TEWI of R407C is the highest among all the considered R22 alternatives and it is higher in the range of 13.28%–17.63%. Similarly, TEWIs of R22 alternatives are lower in the range of 2.48%–17.56% when compared to both R407C and R22. The study exhibited that overall performance of R22 alternatives (R431A, R432A and R433A) is better than R407C and R22.
- 14 October 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 239 (24) , 10175-10186
Critical performance and carbon dioxide emission analysis of low GWP refrigerants R431A, R432A and R433A as replacements to R22 applicable in room air conditioners: An analytical study
The current investigation presents an extensive thermodynamic performance analysis and CO 2 emission analysis of R22 alternatives. Refrigerants such as R431A, R432A and R433A are considered as ozone friendly and low GWP R22 alternatives as per ASHRAE recommendations. Similarly, hydrofluorocarbon (HFC) refrigerant R407C is evaluated as a possible retrofit option for replacing R22. In this study, effect of various operating conditions like variation of superheating, subcooling, evaporation and condensing temperatures are considered in order to evaluate the performance of refrigerants. Moreover, comparative study of hydrocarbon (HC) blends (R431A, R432A and R433A) is made with HFC refrigerant R407C apart from hydrochlorofluorocarbon (HCFC) refrigerant R22. In this work, standard VCR cycle is taken for the thermodynamic analysis whereas CO 2 emissions are assessed by total equivalent warming index (TEWI). Results indicate that coefficient of performances (COPs) of R431A, R432A and R433A are higher in the range of 12.06%–15.98% when compared with R407C and they are relatively lower in the range of 2.73%–3.96% compared to R22. Compressor discharge temperatures of considered R22 alternatives are much lower than that of R407C and R22 by 1.62°C–17.05°C. The volumetric refrigeration capacities of R22 alternatives are higher in the range 0.11%–3.45% when compared with R407C and they are relatively lower in the range of 7.44%–10.82% compared to R22. TEWI of R407C is the highest among all the considered R22 alternatives and it is higher in the range of 13.28%–17.63%. Similarly, TEWIs of R22 alternatives are lower in the range of 2.48%–17.56% when compared to both R407C and R22. The study exhibited that overall performance of R22 alternatives (R431A, R432A and R433A) is better than R407C and R22.
- Open Access
- 1 January 2024
- Published by Wiley in Advances in Civil Engineering
- Vol. 2024 (1)
Thermal Analysis of Building Roofs with Latent Heat Storage for Reduction in Energy Consumption and CO2 Emissions: An Experimental and Numerical Research
In green energy buildings, air conditioning charges can be lowered through careful planning of the building’s envelope. This article investigates several strategically designed phase change material (PCM) roof envelopes for savings on air conditioning prices, CO2 emission abatement, and payback timeframes in hot–arid and warm‐temperate climates, taking into account unsteady heat transfer characteristics, cooling, and heating degree–hours. This is accomplished by using six different PCMs–RCC (reinforced cement concrete) roof envelope cases (RCC roof with PCM layer on the outer side, RCC roof with PCM layer on the center (middle), RCC roof with PCM layer on the inside, RCC roof with PCM layers placed on the outside and center, RCC roof with PCM layers placed on the center and inside, and RCC roof with PCM layers placed on the outer side and inside) with three PCMs (FS29 (form stable mixture), HS29 (hydrated salt), and OM29 (organic mixture)). PCM thermophysical characteristics are experimentally measured. The analytical results are experimentally validated. In hot–arid and warm‐temperate regions, the layer of PCM installed on the outside of the RCC with HS29 saved the most on air conditioning expenses, at 6.29 and 6.61 $/m2, respectively. They also reported the greatest carbon mitigation of 300.55 kg of CO2/year and 281.58 kg of CO2/year with the faster payback periods. PCM roof envelopes are the most energy‐efficient option for green buildings.
- 1 January 2024
- Published by Wiley in Advances in Civil Engineering
- Vol. 2024 (1)
Open AccessThermal Analysis of Building Roofs with Latent Heat Storage for Reduction in Energy Consumption and CO2 Emissions: An Experimental and Numerical Research
In green energy buildings, air conditioning charges can be lowered through careful planning of the building’s envelope. This article investigates several strategically designed phase change material (PCM) roof envelopes for savings on air conditioning prices, CO2 emission abatement, and payback timeframes in hot–arid and warm‐temperate climates, taking into account unsteady heat transfer characteristics, cooling, and heating degree–hours. This is accomplished by using six different PCMs–RCC (reinforced cement concrete) roof envelope cases (RCC roof with PCM layer on the outer side, RCC roof with PCM layer on the center (middle), RCC roof with PCM layer on the inside, RCC roof with PCM layers placed on the outside and center, RCC roof with PCM layers placed on the center and inside, and RCC roof with PCM layers placed on the outer side and inside) with three PCMs (FS29 (form stable mixture), HS29 (hydrated salt), and OM29 (organic mixture)). PCM thermophysical characteristics are experimentally measured. The analytical results are experimentally validated. In hot–arid and warm‐temperate regions, the layer of PCM installed on the outside of the RCC with HS29 saved the most on air conditioning expenses, at 6.29 and 6.61 $/m2, respectively. They also reported the greatest carbon mitigation of 300.55 kg of CO2/year and 281.58 kg of CO2/year with the faster payback periods. PCM roof envelopes are the most energy‐efficient option for green buildings.
- 15 November 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 237 (6) , 2349-2361
Experimental study on effectiveness in segmental baffled shell and tube heat exchanger using Al2O3 nanofluid at variable concentrations
Nanoparticles attracted many researchers because of their significant heat transfer enhancement properties in various applications. The nanoparticles have variable properties and a high specific surface (Cp) area, which enhance heat exchange between fluids and their particles at different volume concentrations. This article provides the outcomes of an experimental study on the overall heat transfer coefficient (Uo) and effectiveness ( ε) of the shell and tube heat exchanger (STHE) with a 25% baffle cut using Al2O3 nanofluid consisting of base fluid distilled water (DW) and Al2O3 nanoparticles at 0.05%, 0.1%, and 0.2% of volume concentrations. Using a two-step method and adding a weight fraction of 0.1% sodium dodecylbenzene sulfonate (SDBS) as a surface active agent to each volume concentration of nanofluid provides better stability. The thermophysical properties like density (ρ), thermal conductivity (k), and dynamic viscosity ( μ) of the Al2O3-DW nanofluid increased, but Cp of the same was reduced by increasing the volume fraction. Al2O3-DW nanofluid at different concentrations in parallel and counter flow variations of the STHE enhances the Uo and ε when compared with water. However, counterflow provides higher effectiveness. At 0.6 LPM of the nanofluid flow and hot fluid at T = 80°C temperature, the difference in the heat exchanger's effectiveness enhancement is 4.24% for parallel flow and 4.16% for counterflow at 0.2% concentration of Al2O3-DW nanofluid compared to water.
- 15 November 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 237 (6) , 2349-2361
Experimental study on effectiveness in segmental baffled shell and tube heat exchanger using Al2O3 nanofluid at variable concentrations
Nanoparticles attracted many researchers because of their significant heat transfer enhancement properties in various applications. The nanoparticles have variable properties and a high specific surface (Cp) area, which enhance heat exchange between fluids and their particles at different volume concentrations. This article provides the outcomes of an experimental study on the overall heat transfer coefficient (Uo) and effectiveness ( ε) of the shell and tube heat exchanger (STHE) with a 25% baffle cut using Al2O3 nanofluid consisting of base fluid distilled water (DW) and Al2O3 nanoparticles at 0.05%, 0.1%, and 0.2% of volume concentrations. Using a two-step method and adding a weight fraction of 0.1% sodium dodecylbenzene sulfonate (SDBS) as a surface active agent to each volume concentration of nanofluid provides better stability. The thermophysical properties like density (ρ), thermal conductivity (k), and dynamic viscosity ( μ) of the Al2O3-DW nanofluid increased, but Cp of the same was reduced by increasing the volume fraction. Al2O3-DW nanofluid at different concentrations in parallel and counter flow variations of the STHE enhances the Uo and ε when compared with water. However, counterflow provides higher effectiveness. At 0.6 LPM of the nanofluid flow and hot fluid at T = 80°C temperature, the difference in the heat exchanger's effectiveness enhancement is 4.24% for parallel flow and 4.16% for counterflow at 0.2% concentration of Al2O3-DW nanofluid compared to water.
- 11 October 2020
- Published by Springer Nature
- p. 317-327
Analytical Computation of Thermodynamic Performance of Various New Eco-friendly Alternative Refrigerants Applicable for Air Conditioners
- 11 October 2020
- Published by Springer Nature
- p. 317-327
Analytical Computation of Thermodynamic Performance of Various New Eco-friendly Alternative Refrigerants Applicable for Air Conditioners
- 18 July 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (33) , 41415-41436
Investigation on thermodynamic performance analysis and environmental effects of various new refrigerants used in air conditioners
The main aim of this present investigation is to evaluate performance and environmental impact analysis of various novel mixture refrigerants as R22 replacements theoretically. Refrigerants with lower global warming potential (GWP) can be adequate for bringing down emissions which are concerned for air conditioners. In this investigation, twenty-seven refrigerants were developed at several compositions. Important studies such as computation of CO2 emissions using total equivalent warming impact (TEWI), toxicity and flammability analysis of various considered refrigerants were also carried out in this investigation. Performance analysis of refrigerants was conducted under different operating conditions. Results showed that the energy efficiency ratios (EERs) of refrigerants such as R1270, RM30 (R152a/R1270/RE170 of 25/71/4 by mass percentage) and RM50 (R152a/R1270/RE170 of 10/85/5 by mass percentage) were closer to that of R22 and they are relatively lower than R22 by 0.95%, 1.34% and 1.80%, respectively. Toxicity investigation exhibited that all the refrigerants studied were classified into nontoxic category (A) whereas flammability investigation revealed that all the novel refrigerant mixtures (RM10 to RM50) were classified into flammable category (A3). CO2 emissions (TEWI) released from air conditioner working with R1270, RM30 and RM50 were 7.41%, 6.85% and 6.51%, respectively, lower than that of R22. In terms of several thermodynamic aspects, the performance of refrigerants such as R1270, RM30 and RM50 were superior to those of R22 and its various considered alternatives working under different operating conditions, although their EERs are fairly lower than R22 and hence, these refrigerants could be considered suitable environment-friendly alternatives to R22 used in air conditioners. The present study gives essential information and a road map towards the development of low GWP R22 alternative refrigerant blends from the viewpoint of toxicity, flammability, performance aspects, environmental and safety aspects, respectively.
- 18 July 2020
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 27 (33) , 41415-41436
Investigation on thermodynamic performance analysis and environmental effects of various new refrigerants used in air conditioners
The main aim of this present investigation is to evaluate performance and environmental impact analysis of various novel mixture refrigerants as R22 replacements theoretically. Refrigerants with lower global warming potential (GWP) can be adequate for bringing down emissions which are concerned for air conditioners. In this investigation, twenty-seven refrigerants were developed at several compositions. Important studies such as computation of CO2 emissions using total equivalent warming impact (TEWI), toxicity and flammability analysis of various considered refrigerants were also carried out in this investigation. Performance analysis of refrigerants was conducted under different operating conditions. Results showed that the energy efficiency ratios (EERs) of refrigerants such as R1270, RM30 (R152a/R1270/RE170 of 25/71/4 by mass percentage) and RM50 (R152a/R1270/RE170 of 10/85/5 by mass percentage) were closer to that of R22 and they are relatively lower than R22 by 0.95%, 1.34% and 1.80%, respectively. Toxicity investigation exhibited that all the refrigerants studied were classified into nontoxic category (A) whereas flammability investigation revealed that all the novel refrigerant mixtures (RM10 to RM50) were classified into flammable category (A3). CO2 emissions (TEWI) released from air conditioner working with R1270, RM30 and RM50 were 7.41%, 6.85% and 6.51%, respectively, lower than that of R22. In terms of several thermodynamic aspects, the performance of refrigerants such as R1270, RM30 and RM50 were superior to those of R22 and its various considered alternatives working under different operating conditions, although their EERs are fairly lower than R22 and hence, these refrigerants could be considered suitable environment-friendly alternatives to R22 used in air conditioners. The present study gives essential information and a road map towards the development of low GWP R22 alternative refrigerant blends from the viewpoint of toxicity, flammability, performance aspects, environmental and safety aspects, respectively.
- 29 May 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 234 (4) , 367-385
Theoretical energy performance assessment and environmental impact of various new ozone-friendly refrigerants used in residential air conditioners
This study focuses on energy performance investigation and environmental impact analysis of various new ecofriendly refrigerant blends as alternatives to high global warming potential refrigerant R22 theoretically. In this study, 23 refrigerants were considered at various composition. The present work considered the practical vapour compression refrigeration cycle for the performance assessment of various R22 alternatives. Essential studies such as toxicity, flammability, and total equivalent warming index of various novel refrigerants were also conducted in this study. Results obtained from practical vapour compression refrigeration cycle revealed that the energy efficiency ratio of refrigerants such as R1270 (2.860) and RB03 (R290/R152a of 60/40 in mass %) (2.854) was closer to the energy efficiency ratio of R22 (2.940). Volumetric refrigeration capacity (VRC) of R1270 (3293 kJ/m3) was similar to that of R22 (3297 kJ/m3) whereas VRC of RB03 (2908 kJ/m3) was almost similar to that of R407C (2925 kJ/m3) which was an alternative to R22. Compressor discharge temperature of RB03 was 15.78 ℃ lower when compared to R22. Flammability study revealed that all the new refrigerant blends (RB01 to RB04) were classified into weakly flammable (A2) and flammable (A3) category refrigerants whereas toxicity study revealed that all the investigated refrigerants were classified into non-toxic group (A). Refrigerant blend RB03 was less flammable compared to R1270. Total equivalent warming index analysis revealed that the environmental impact of R422A was 27.88% higher than R22 whereas RB03 has 4.97% lower environmental impact compared to R22. Overall, performance of refrigerant blend RB03 was better compared to 23 investigated refrigerants and it was very nearer to the performance of R22 and hence, it could be considered as an ecofriendly alternative to replace high global warming potential refrigerant R22 used in air conditioners.
- 29 May 2020
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
- Vol. 234 (4) , 367-385
Theoretical energy performance assessment and environmental impact of various new ozone-friendly refrigerants used in residential air conditioners
This study focuses on energy performance investigation and environmental impact analysis of various new ecofriendly refrigerant blends as alternatives to high global warming potential refrigerant R22 theoretically. In this study, 23 refrigerants were considered at various composition. The present work considered the practical vapour compression refrigeration cycle for the performance assessment of various R22 alternatives. Essential studies such as toxicity, flammability, and total equivalent warming index of various novel refrigerants were also conducted in this study. Results obtained from practical vapour compression refrigeration cycle revealed that the energy efficiency ratio of refrigerants such as R1270 (2.860) and RB03 (R290/R152a of 60/40 in mass %) (2.854) was closer to the energy efficiency ratio of R22 (2.940). Volumetric refrigeration capacity (VRC) of R1270 (3293 kJ/m3) was similar to that of R22 (3297 kJ/m3) whereas VRC of RB03 (2908 kJ/m3) was almost similar to that of R407C (2925 kJ/m3) which was an alternative to R22. Compressor discharge temperature of RB03 was 15.78 ℃ lower when compared to R22. Flammability study revealed that all the new refrigerant blends (RB01 to RB04) were classified into weakly flammable (A2) and flammable (A3) category refrigerants whereas toxicity study revealed that all the investigated refrigerants were classified into non-toxic group (A). Refrigerant blend RB03 was less flammable compared to R1270. Total equivalent warming index analysis revealed that the environmental impact of R422A was 27.88% higher than R22 whereas RB03 has 4.97% lower environmental impact compared to R22. Overall, performance of refrigerant blend RB03 was better compared to 23 investigated refrigerants and it was very nearer to the performance of R22 and hence, it could be considered as an ecofriendly alternative to replace high global warming potential refrigerant R22 used in air conditioners.
- 4 November 2019
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 234 (4) , 914-934
Theoretical thermodynamic performance assessment of various environment-friendly novel refrigerants used in refrigeration systems
The present investigation focuses on theoretical performance of various new environment-friendly refrigerant mixtures as substitutes to high global warming potential refrigerant R22. In this investigation, 34 refrigerants were considered at various composition. In this work, both complex vapor compression cycle (actual cycle) and standard vapor compression cycle (ideal cycle) was considered for the performance assessment of refrigerants. Vital studies such as flammability, toxicity, and environmental impact of various novel refrigerants were also carried out in this study. Results obtained from actual cycle showed that the coefficient of performance of refrigerant mixture RM40 (R1270/R134a 90/10 in mass %) (2.728) was the greatest among 34 investigated alternatives and it was closer to the coefficient of performance of R22 (2.770). Compressor discharge temperature of RM40 was 13.36 ℃ lower when compared with R22. Volumetric refrigeration capacity of RM40 (3335 kJ/m3) was slightly higher than that of R22 (3297 kJ/m3). Power spent per ton of refrigeration of RM40 (1.288 kW/TR) was marginally higher than that of R22 (1.269 kW/TR). Global warming potential (GWP100) of RM40 (133) was very low compared to the GWP100 of R22 (1760). Total equivalent warming index (environmental impact) of RM40 was 5.61% lower than R22. However, performance results obtained from standard cycle for various investigated refrigerants were better than actual cycle, since various losses occur were neglected in the standard cycle. Overall, thermodynamic performance of refrigerant mixture RM40 (R1270/R134a 90/10 in mass %) obtained from both actual and standard cycle was the highest among 34 investigated refrigerants and it was very closer to the performance of R22 and hence, it could be considered as an environment-friendly alternative to replace high GWP refrigerant R22 used in refrigeration systems.
- 4 November 2019
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 234 (4) , 914-934
Theoretical thermodynamic performance assessment of various environment-friendly novel refrigerants used in refrigeration systems
The present investigation focuses on theoretical performance of various new environment-friendly refrigerant mixtures as substitutes to high global warming potential refrigerant R22. In this investigation, 34 refrigerants were considered at various composition. In this work, both complex vapor compression cycle (actual cycle) and standard vapor compression cycle (ideal cycle) was considered for the performance assessment of refrigerants. Vital studies such as flammability, toxicity, and environmental impact of various novel refrigerants were also carried out in this study. Results obtained from actual cycle showed that the coefficient of performance of refrigerant mixture RM40 (R1270/R134a 90/10 in mass %) (2.728) was the greatest among 34 investigated alternatives and it was closer to the coefficient of performance of R22 (2.770). Compressor discharge temperature of RM40 was 13.36 ℃ lower when compared with R22. Volumetric refrigeration capacity of RM40 (3335 kJ/m3) was slightly higher than that of R22 (3297 kJ/m3). Power spent per ton of refrigeration of RM40 (1.288 kW/TR) was marginally higher than that of R22 (1.269 kW/TR). Global warming potential (GWP100) of RM40 (133) was very low compared to the GWP100 of R22 (1760). Total equivalent warming index (environmental impact) of RM40 was 5.61% lower than R22. However, performance results obtained from standard cycle for various investigated refrigerants were better than actual cycle, since various losses occur were neglected in the standard cycle. Overall, thermodynamic performance of refrigerant mixture RM40 (R1270/R134a 90/10 in mass %) obtained from both actual and standard cycle was the highest among 34 investigated refrigerants and it was very closer to the performance of R22 and hence, it could be considered as an environment-friendly alternative to replace high GWP refrigerant R22 used in refrigeration systems.
- 28 September 2019
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 37 (3) , 869-880
Computation of Ecological Properties, Flammability Properties and Thermodynamic Properties of Sustainable Refrigerant Dimethylether (RE170) Using Martin Hou Equation of State (MHEOS)
- 28 September 2019
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 37 (3) , 869-880
Computation of Ecological Properties, Flammability Properties and Thermodynamic Properties of Sustainable Refrigerant Dimethylether (RE170) Using Martin Hou Equation of State (MHEOS)