Abstract
A technique is introduced for studying plasma-material interactions in high-flux linear plasma devices at various ion incident angles. The technique requires preparing material samples with micro-trenches at various incident angles, wherein the dimensions of the micro-trenches are kept smaller than the plasma sheath thickness such that plasma ions accelerated through the sheath remain normal to the sample surface. The technique is validated with the formation of cone structures on a chromium sample exposed to helium plasma at 100 eV, where the cones generated on the 23–90°angled walls of the micro-trench remained normal to the global sample surface. Hence, glancing angles more akin to conditions at the divertor of magnetic confinement fusion devices can be achieved in linear plasma devices utilizing this technique with angular micro-trenches, while still maintaining the high-fluxes comparable to fusion conditions. In addition, the size of chromium cones increased with increasing helium incidence angle, suggesting enhanced modification expected for chromium-containing plasma-facing components at the divertor.
Funding Information
  • U.S. Department of Energy (DE-SC0022528)

This publication has 26 references indexed in Scilit: