Michael James Simmonds
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael James Simmonds has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- Matthew J. Baldwin
Center for Energy Research, University of California San Diego, La Jolla, CA 92093-0417, United States of America
21 shared publications - Anze Zaloznik
Center for Energy Research, University of California San Diego, 9500 Gilman Dr, La Jolla, California, 92093-0021, UNITED STATES
14 shared publications - Daisuke Nishijima
Center for Energy Research, University of California San Diego, La Jolla, CA 92093-0417, United States of America
10 shared publications G.R. Tynan
10 shared publications- Marlene I. Patino
Center for Energy Research, University of California at San Diego, La Jolla, CA, United States of America
10 shared publications R.P. Doerner
Center for Energy Research, University of California—San Diego, La Jolla, CA 92093-0417, United States of America
10 shared publications
Latest Publications
- Open Access
- 5 May 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (18) , 185601
Technique for studying angular-dependent plasma-material interactions in high-flux plasma devices using angular micro-trenches and application to chromium cone formation
A technique is introduced for studying plasma-material interactions in high-flux linear plasma devices at various ion incident angles. The technique requires preparing material samples with micro-trenches at various incident angles, wherein the dimensions of the micro-trenches are kept smaller than the plasma sheath thickness such that plasma ions accelerated through the sheath remain normal to the sample surface. The technique is validated with the formation of cone structures on a chromium sample exposed to helium plasma at 100 eV, where the cones generated on the 23–90°angled walls of the micro-trench remained normal to the global sample surface. Hence, glancing angles more akin to conditions at the divertor of magnetic confinement fusion devices can be achieved in linear plasma devices utilizing this technique with angular micro-trenches, while still maintaining the high-fluxes comparable to fusion conditions. In addition, the size of chromium cones increased with increasing helium incidence angle, suggesting enhanced modification expected for chromium-containing plasma-facing components at the divertor.
- 5 May 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (18) , 185601
Open AccessTechnique for studying angular-dependent plasma-material interactions in high-flux plasma devices using angular micro-trenches and application to chromium cone formation
A technique is introduced for studying plasma-material interactions in high-flux linear plasma devices at various ion incident angles. The technique requires preparing material samples with micro-trenches at various incident angles, wherein the dimensions of the micro-trenches are kept smaller than the plasma sheath thickness such that plasma ions accelerated through the sheath remain normal to the sample surface. The technique is validated with the formation of cone structures on a chromium sample exposed to helium plasma at 100 eV, where the cones generated on the 23–90°angled walls of the micro-trench remained normal to the global sample surface. Hence, glancing angles more akin to conditions at the divertor of magnetic confinement fusion devices can be achieved in linear plasma devices utilizing this technique with angular micro-trenches, while still maintaining the high-fluxes comparable to fusion conditions. In addition, the size of chromium cones increased with increasing helium incidence angle, suggesting enhanced modification expected for chromium-containing plasma-facing components at the divertor.
- 1 May 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (5)
A simplified di-homodyne transient grating spectroscopy system utilizing polarization
A modification to the di-homodyne transient grating spectroscopy optical arrangement is presented that removes the need to individually align two spatially separated probe laser beams. This work details the novel application of a single probe beam that utilizes birefringent materials to produce two optically homodyned signals with a relative phase shift of π radians. This arrangement effectively simplifies the alignment to one probe beam and removes the relative phase shift ambiguity between each homodyned signal. Several example measurements for tungsten, titanium, molybdenum, and silicon are shown to illustrate the utility of the new optical system.
- 1 May 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (5)
A simplified di-homodyne transient grating spectroscopy system utilizing polarization
A modification to the di-homodyne transient grating spectroscopy optical arrangement is presented that removes the need to individually align two spatially separated probe laser beams. This work details the novel application of a single probe beam that utilizes birefringent materials to produce two optically homodyned signals with a relative phase shift of π radians. This arrangement effectively simplifies the alignment to one probe beam and removes the relative phase shift ambiguity between each homodyned signal. Several example measurements for tungsten, titanium, molybdenum, and silicon are shown to illustrate the utility of the new optical system.
- Open Access
- 24 April 2026
- Published by Elsevier in SSRN Electronic Journal
POSEIDON: Coupled linear plasma device and ion beam accelerator for the study of simultaneous plasma exposure and displacement damage
A new experimental system for simultaneous energetic ion beam irradiation and plasma exposure, POSEIDON, is introduced. The system consists of a new 3 MV ion beam accelerator, coupled with the PISCES-RF linear plasma device. In our first experiments on tungsten (W) targets, a defocused 20 MeV W6+ ion beam, impinging at 30° with respect to the sample surface normal, delivered damage rates up to 6×10-5 dpa/s with a 15% spatial variance between the center and the edge of the 10 mm wide exposed area. A higher damage rate is easily achievable at the expense of a higher spatial variance. New ion beam diagnostic tools have been developed inside PISCES-RF and tested in our first simultaneous irradiation and exposure experiments. The stability of the beam under typical magnetic field and operating gas pressure has been tested and confirmed by analyzing the fluorescence of a quartz scintillator. The SIREN endstation for ion beam irradiation and ex-situ ion beam analysis is also introduced and described. The first data, comparing sequential and simultaneous damaging and D plasma exposure of W at 333 K is presented and discussed.
- 24 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPOSEIDON: Coupled linear plasma device and ion beam accelerator for the study of simultaneous plasma exposure and displacement damage
A new experimental system for simultaneous energetic ion beam irradiation and plasma exposure, POSEIDON, is introduced. The system consists of a new 3 MV ion beam accelerator, coupled with the PISCES-RF linear plasma device. In our first experiments on tungsten (W) targets, a defocused 20 MeV W6+ ion beam, impinging at 30° with respect to the sample surface normal, delivered damage rates up to 6×10-5 dpa/s with a 15% spatial variance between the center and the edge of the 10 mm wide exposed area. A higher damage rate is easily achievable at the expense of a higher spatial variance. New ion beam diagnostic tools have been developed inside PISCES-RF and tested in our first simultaneous irradiation and exposure experiments. The stability of the beam under typical magnetic field and operating gas pressure has been tested and confirmed by analyzing the fluorescence of a quartz scintillator. The SIREN endstation for ion beam irradiation and ex-situ ion beam analysis is also introduced and described. The first data, comparing sequential and simultaneous damaging and D plasma exposure of W at 333 K is presented and discussed.
- 19 March 2026
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 627
Growth of deuterium supersaturated surface layer with increasing ion flux and fluence in plasma-exposed tungsten
- 19 March 2026
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 627
Growth of deuterium supersaturated surface layer with increasing ion flux and fluence in plasma-exposed tungsten
- Open Access
- 5 May 2025
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 43
A first study of the complex-concentrated-alloy W38Ta36Cr15V11 in Pisces-RF high-flux deuterium plasma
- 5 May 2025
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 43
Open AccessA first study of the complex-concentrated-alloy W38Ta36Cr15V11 in Pisces-RF high-flux deuterium plasma
- Open Access
- 7 March 2025
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 43
Deuterium retention in pre-lithiated samples and Li–D co-deposits in the DIII-D tokamak
- 7 March 2025
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 43
Open AccessDeuterium retention in pre-lithiated samples and Li–D co-deposits in the DIII-D tokamak
- Open Access
- 5 March 2025
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 43
First in operando transient grating spectroscopy measurements on tungsten during high flux plasma operation in PISCES-RF
- 5 March 2025
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 43
Open AccessFirst in operando transient grating spectroscopy measurements on tungsten during high flux plasma operation in PISCES-RF
- Open Access
- 14 November 2024
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 41
The effect of D partial pressure, deposition rate, and sample temperature on D retention in W codeposited layers- 14 November 2024
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 41
Open AccessThe effect of D partial pressure, deposition rate, and sample temperature on D retention in W codeposited layers - Open Access
- 1 October 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (10)
An increased accuracy laser-induced transient grating spectroscopy analysis method for probing near surface thermal diffusivity with gigahertz frequency instrumentation
An updated analysis method for laser-induced transient grating spectroscopy measurements of near-surface thermal diffusivity using gigahertz frequency instrumentation is presented. Considering the particular application of characterizing materials with heavy ion damage, prior analysis methods typically assume a very short excitation pulse relative to the relaxation time of the response signal. For longer pulse durations, this can be an increasingly poor assumption with decreasing probing depth. This work presents the application of convolution to update the previous analysis method. As a case study, a 400 ps excitation laser pulse on tungsten with transient grating wavelengths of 1.33–20.0 μm, corresponding to characteristic decay times of 0.633–143 ns, is analyzed. Transient grating response curves from numerical simulations and experimental transient grating spectroscopy data are fit using each analysis method, with and without convolution, and compared. Considerations with regard to the data collection instruments are also detailed.
- 1 October 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (10)
Open AccessAn increased accuracy laser-induced transient grating spectroscopy analysis method for probing near surface thermal diffusivity with gigahertz frequency instrumentation
An updated analysis method for laser-induced transient grating spectroscopy measurements of near-surface thermal diffusivity using gigahertz frequency instrumentation is presented. Considering the particular application of characterizing materials with heavy ion damage, prior analysis methods typically assume a very short excitation pulse relative to the relaxation time of the response signal. For longer pulse durations, this can be an increasingly poor assumption with decreasing probing depth. This work presents the application of convolution to update the previous analysis method. As a case study, a 400 ps excitation laser pulse on tungsten with transient grating wavelengths of 1.33–20.0 μm, corresponding to characteristic decay times of 0.633–143 ns, is analyzed. Transient grating response curves from numerical simulations and experimental transient grating spectroscopy data are fit using each analysis method, with and without convolution, and compared. Considerations with regard to the data collection instruments are also detailed.