Validation of ELDO approaches for retrospective assessment of cumulative eye lens doses of interventional cardiologists—results from DoReMi project
- 15 September 2016
- journal article
- research article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36 (4) , 736-745
Abstract
The first validation results of the two approaches developed in the ELDO project for retrospective assessment of eye lens doses for interventional cardiologists (ICs) are presented in this paper. The first approach (a) is based on both the readings from the routine whole body dosimeter worn above the lead apron and procedure-dependent conversion coefficients, while the second approach (b) is based on detailed information related to the occupational exposure history of the ICs declared in a questionnaire and eye lens dose records obtained from the relevant literature. The latter approach makes use of various published eye lens doses per procedure as well as the appropriate correction factors which account for the use of radiation protective tools designed to protect the eye lens. To validate both methodologies, comprehensive measurements were performed in several Polish clinics among recruited physicians. Two dosimeters measuring whole body and eye lens doses were worn by every physician for at least two months. The estimated cumulative eye lens doses, calculated from both approaches, were then compared against the measured eye lens dose value for every physician separately. Both approaches results in comparable estimates of eye lens doses and tend to overestimate rather than underestimate the eye lens doses. The measured and estimated doses do not differ, on average, by a factor higher than 2.0 in 85% and 62% of the cases used to validate approach (a) and (b), respectively. In specific cases, however, the estimated doses differ from the measured ones by as much as a factor of 2.7 and 5.1 for method (a) and (b), respectively. As such, the two approaches can be considered accurate when retrospectively estimating the eye lens doses for ICs and will be of great benefit for ongoing epidemiological studies.Keywords
Funding Information
- DOREMI (FP7/249689)
This publication has 11 references indexed in Scilit:
- Characteristics of interventional cardiologists and their work practices for the study on radiation-induced lens opacities based on the methodology developed by ELDO—preliminary resultsJournal of Radiation Research, 2016
- The impact of various protective tools on the dose reduction in the eye lens in an interventional cardiology—clinical studyJournal of Radiological Protection, 2016
- FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONSRadiation Protection Dosimetry, 2015
- Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologistsRadiation Protection Dosimetry, 2014
- Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body dosesJournal of Radiological Protection, 2014
- A correlation study of eye lens dose and personal dose equivalent for interventional cardiologistsRadiation Protection Dosimetry, 2013
- Eye lens radiation exposure to interventional cardiologists: a retrospective assessment of cumulativedosesRadiation Protection Dosimetry, 2012
- A study of the dose distribution in the region of the eye lens and extremities for staff working in interventional cardiologyRadiation Measurements, 2012
- Study of the parameters affecting operator doses in interventional radiology using Monte Carlo simulationsRadiation Measurements, 2011
- Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED projectRadiation Measurements, 2011