Joanna Domienik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joanna Domienik has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Marcin Brodecki
Nofer Institute of Occupational Medicine
4 shared publications D. Rusicka
Nofer Institute of Occupational Medicine, St. Teresa 8, 91-348 Lodz, Poland
2 shared publicationsA Bissinger
Department of Invasive Cardiology and Cardiodiabetology, Medical University of Lodz, Lodz, Poland
1 shared publicationA Lubiński
Department of Invasive Cardiology and Cardiodiabetology, Medical University of Lodz, Lodz, Poland
1 shared publicationA. Werduch
Institute of Physics, University of Lodz , Department of Nuclear Physics and Radiation Safety, Pomorska 149/153 St, 90-236 Lodz , Poland
1 shared publicationAnders Widmark
Norwegian Radiation Protection Authority (NRPA), Østerås, Norway
1 shared publication
Latest Publications
- 12 June 2018
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 38 (3) , 934-950
Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens—results of the EURALOC study
This paper investigates over five decades of work practices in interventional cardiology, with an emphasis on radiation protection. The analysis is based on data from more than 400 cardiologists from various European countries recruited for a EURALOC study and collected in the period from 2014 to 2016. Information on the types of procedures performed and their annual mean number, fluoroscopy time, access site choice, x-ray units and radiation protection means used was collected using an occupational questionnaire. Based on the specific European data, changes in each parameter have been analysed over decades, while country-specific data analysis has allowed us to determine the differences in local practices. In particular, based on the collected data, the typical workload of a European cardiologist working in a haemodynamic room and an electrophysiology room was specified for various types of procedures. The results showed that when working in a haemodynamic room, a transparent ceiling-suspended lead shield or lead glasses are necessary in order to remain below the recommended eye lens dose limit of 20 mSv. Moreover, the analysis revealed that new, more complex cardiac procedures such as chronic total occlusion, valvuloplasty and pulmonary vein isolation for atrial fibrillation ablation might contribute substantially to annual doses, although they are relatively rarely performed. The results revealed that considerable progress has been made in the use of radiation protection tools. While their use in electrophysiology procedures is not generic, the situation in haemodynamic procedures is rather encouraging, as ceiling-suspended shields are used in 90% of cases, while the combination of ceiling shield and lead glasses is noted in more than 40% of the procedures. However, we find that still 7% of haemodynamic procedures are performed without any radiation protection tools.
- 12 June 2018
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 38 (3) , 934-950
Past and present work practices of European interventional cardiologists in the context of radiation protection of the eye lens—results of the EURALOC study
This paper investigates over five decades of work practices in interventional cardiology, with an emphasis on radiation protection. The analysis is based on data from more than 400 cardiologists from various European countries recruited for a EURALOC study and collected in the period from 2014 to 2016. Information on the types of procedures performed and their annual mean number, fluoroscopy time, access site choice, x-ray units and radiation protection means used was collected using an occupational questionnaire. Based on the specific European data, changes in each parameter have been analysed over decades, while country-specific data analysis has allowed us to determine the differences in local practices. In particular, based on the collected data, the typical workload of a European cardiologist working in a haemodynamic room and an electrophysiology room was specified for various types of procedures. The results showed that when working in a haemodynamic room, a transparent ceiling-suspended lead shield or lead glasses are necessary in order to remain below the recommended eye lens dose limit of 20 mSv. Moreover, the analysis revealed that new, more complex cardiac procedures such as chronic total occlusion, valvuloplasty and pulmonary vein isolation for atrial fibrillation ablation might contribute substantially to annual doses, although they are relatively rarely performed. The results revealed that considerable progress has been made in the use of radiation protection tools. While their use in electrophysiology procedures is not generic, the situation in haemodynamic procedures is rather encouraging, as ceiling-suspended shields are used in 90% of cases, while the combination of ceiling shield and lead glasses is noted in more than 40% of the procedures. However, we find that still 7% of haemodynamic procedures are performed without any radiation protection tools.
- 28 July 2017
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 37 (3) , 715-727
Effectiveness of pelvic lead blanket to reduce the doses to eye lens and hands of interventional cardiologists and assistant nurses
The aim of the present study is to analyse quantitatively the potential reduction of doses to the eye lens and the hands of an operator and a nurse by the use of a pelvic lead blanket during coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) procedures. Thermoluminescent dosimeters were used to assess dose levels to the left eye lens and fingers on both hands of both physician and nurses during single procedures performed with or without the lead blanket. The measurements were carried out at one medical centre and include dosimetric data from 100 procedures. Additional measurements including physician’s and patient’s doses were made on phantoms in the laboratory. In order to determine the reduction potential of the lead blanket, the doses normalized to DAP (Dose-Area Product) corresponding to the same position of dosimeter were compared against each other for both procedure categories (with and without protection). There was no statistically significant decrease observed in physicians’ and nurses’ eye lens doses, nor in doses normalized to DAP due to the use of the lead pelvic shield in clinic. However, some trend in reducing the eye lens doses by this shield can be observed. Regarding finger doses, the differences are statistically significant but only for physicians. The mean DAP-normalised doses to the eye lens and left and right finger of physicians, in the presence of a ceiling-suspended transparent lead shield, were 2.24e-5 ± 1.41e-5 mSv/ μ Gym 2 , 2.31e-4 ± 1.21e-4 mSv/ μ Gym 2 , and 2.60e-5 ± 1.57e-5 mSv/ μ Gym 2 for standard procedures performed without the lead blanket, and 1.77e-5 ± 1.17e-5 mSv/ μ Gym 2 , 1.70e-4 ± 1.01e-4 mSv/ μ Gym 2 , and 1.86e-5 ± 1.13e-5 mSv/ μ Gym 2 for procedures performed with it. A comparison of the results from the laboratory and the clinic shows that they are consistent regarding the eye lens, while for fingers it suggests that the dose reduction properties of the lead shield are related to the physician’s work technique and both patient and lead blanket sizes or its positioning. The highest degree of reduction is observed for cranial and caudal projections together with the use of a patient-adjustable lead blanket; about a 2-fold decrease in finger doses is expected for optimum conditions. However, the laboratory measurements suggest that the use of lead blanket might slightly increase the patient dose, but only when specific projections are constantly used. This limitation should be considered by cardiologists during clinical work if this protection is used. In the light of the presented results, the ceiling-suspended transparent lead shield and the lead glasses seem to be the preferred way to reduce the doses to the eye lens, compared to the lead blanket.
- 28 July 2017
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 37 (3) , 715-727
Effectiveness of pelvic lead blanket to reduce the doses to eye lens and hands of interventional cardiologists and assistant nurses
The aim of the present study is to analyse quantitatively the potential reduction of doses to the eye lens and the hands of an operator and a nurse by the use of a pelvic lead blanket during coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) procedures. Thermoluminescent dosimeters were used to assess dose levels to the left eye lens and fingers on both hands of both physician and nurses during single procedures performed with or without the lead blanket. The measurements were carried out at one medical centre and include dosimetric data from 100 procedures. Additional measurements including physician’s and patient’s doses were made on phantoms in the laboratory. In order to determine the reduction potential of the lead blanket, the doses normalized to DAP (Dose-Area Product) corresponding to the same position of dosimeter were compared against each other for both procedure categories (with and without protection). There was no statistically significant decrease observed in physicians’ and nurses’ eye lens doses, nor in doses normalized to DAP due to the use of the lead pelvic shield in clinic. However, some trend in reducing the eye lens doses by this shield can be observed. Regarding finger doses, the differences are statistically significant but only for physicians. The mean DAP-normalised doses to the eye lens and left and right finger of physicians, in the presence of a ceiling-suspended transparent lead shield, were 2.24e-5 ± 1.41e-5 mSv/ μ Gym 2 , 2.31e-4 ± 1.21e-4 mSv/ μ Gym 2 , and 2.60e-5 ± 1.57e-5 mSv/ μ Gym 2 for standard procedures performed without the lead blanket, and 1.77e-5 ± 1.17e-5 mSv/ μ Gym 2 , 1.70e-4 ± 1.01e-4 mSv/ μ Gym 2 , and 1.86e-5 ± 1.13e-5 mSv/ μ Gym 2 for procedures performed with it. A comparison of the results from the laboratory and the clinic shows that they are consistent regarding the eye lens, while for fingers it suggests that the dose reduction properties of the lead shield are related to the physician’s work technique and both patient and lead blanket sizes or its positioning. The highest degree of reduction is observed for cranial and caudal projections together with the use of a patient-adjustable lead blanket; about a 2-fold decrease in finger doses is expected for optimum conditions. However, the laboratory measurements suggest that the use of lead blanket might slightly increase the patient dose, but only when specific projections are constantly used. This limitation should be considered by cardiologists during clinical work if this protection is used. In the light of the presented results, the ceiling-suspended transparent lead shield and the lead glasses seem to be the preferred way to reduce the doses to the eye lens, compared to the lead blanket.
- 6 December 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 37 (1) , N1-N4
A methodology to split the total cumulative Hp(10) dose into the Hp(10) i doses received during various procedures performed by interventional cardiologist
The methodology describing how to split the cumulative Hp(10) dose of interventional cardiologists into Hp(10) i doses received during procedures of various types based on procedure-specific ELDO coefficients and Hp(3) doses per procedure is presented. The appropriate equations for Hp(10) i (Hp(10) for procedure type i ), depending on the number of various procedure types ( i = 1 … 4) performed by a particular physician, are derived. The methodology can be applied to whole-body doses measured on the lead apron and therefore can be used for optimisation of work practices in those catheterisation labs where routine dosimeter is worn above the apron.
- 6 December 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 37 (1) , N1-N4
A methodology to split the total cumulative Hp(10) dose into the Hp(10) i doses received during various procedures performed by interventional cardiologist
The methodology describing how to split the cumulative Hp(10) dose of interventional cardiologists into Hp(10) i doses received during procedures of various types based on procedure-specific ELDO coefficients and Hp(3) doses per procedure is presented. The appropriate equations for Hp(10) i (Hp(10) for procedure type i ), depending on the number of various procedure types ( i = 1 … 4) performed by a particular physician, are derived. The methodology can be applied to whole-body doses measured on the lead apron and therefore can be used for optimisation of work practices in those catheterisation labs where routine dosimeter is worn above the apron.
- 15 September 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36 (4) , 736-745
Validation of ELDO approaches for retrospective assessment of cumulative eye lens doses of interventional cardiologists—results from DoReMi project
The first validation results of the two approaches developed in the ELDO project for retrospective assessment of eye lens doses for interventional cardiologists (ICs) are presented in this paper. The first approach (a) is based on both the readings from the routine whole body dosimeter worn above the lead apron and procedure-dependent conversion coefficients, while the second approach (b) is based on detailed information related to the occupational exposure history of the ICs declared in a questionnaire and eye lens dose records obtained from the relevant literature. The latter approach makes use of various published eye lens doses per procedure as well as the appropriate correction factors which account for the use of radiation protective tools designed to protect the eye lens. To validate both methodologies, comprehensive measurements were performed in several Polish clinics among recruited physicians. Two dosimeters measuring whole body and eye lens doses were worn by every physician for at least two months. The estimated cumulative eye lens doses, calculated from both approaches, were then compared against the measured eye lens dose value for every physician separately. Both approaches results in comparable estimates of eye lens doses and tend to overestimate rather than underestimate the eye lens doses. The measured and estimated doses do not differ, on average, by a factor higher than 2.0 in 85% and 62% of the cases used to validate approach (a) and (b), respectively. In specific cases, however, the estimated doses differ from the measured ones by as much as a factor of 2.7 and 5.1 for method (a) and (b), respectively. As such, the two approaches can be considered accurate when retrospectively estimating the eye lens doses for ICs and will be of great benefit for ongoing epidemiological studies.
- 15 September 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36 (4) , 736-745
Validation of ELDO approaches for retrospective assessment of cumulative eye lens doses of interventional cardiologists—results from DoReMi project
The first validation results of the two approaches developed in the ELDO project for retrospective assessment of eye lens doses for interventional cardiologists (ICs) are presented in this paper. The first approach (a) is based on both the readings from the routine whole body dosimeter worn above the lead apron and procedure-dependent conversion coefficients, while the second approach (b) is based on detailed information related to the occupational exposure history of the ICs declared in a questionnaire and eye lens dose records obtained from the relevant literature. The latter approach makes use of various published eye lens doses per procedure as well as the appropriate correction factors which account for the use of radiation protective tools designed to protect the eye lens. To validate both methodologies, comprehensive measurements were performed in several Polish clinics among recruited physicians. Two dosimeters measuring whole body and eye lens doses were worn by every physician for at least two months. The estimated cumulative eye lens doses, calculated from both approaches, were then compared against the measured eye lens dose value for every physician separately. Both approaches results in comparable estimates of eye lens doses and tend to overestimate rather than underestimate the eye lens doses. The measured and estimated doses do not differ, on average, by a factor higher than 2.0 in 85% and 62% of the cases used to validate approach (a) and (b), respectively. In specific cases, however, the estimated doses differ from the measured ones by as much as a factor of 2.7 and 5.1 for method (a) and (b), respectively. As such, the two approaches can be considered accurate when retrospectively estimating the eye lens doses for ICs and will be of great benefit for ongoing epidemiological studies.
- Open Access
- 1 July 2016
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 57 (4) , 431-437
Characteristics of interventional cardiologists and their work practices for the study on radiation-induced lens opacities based on the methodology developed by ELDO—preliminary results
Preliminary results of the Polish epidemiology study on eye lens opacities among interventional cardiologists (ICs), based on the methodology proposed by ELDO (epidemiological studies of radio-induced cataracts in interventional cardiologists and radiologists: methodology implementation), are presented. The aim of the study is to test the hypothesis concerning the excess risk of cataract in the group of ICs. The first results concern the study population characteristics, including the most important confounding factors for cataract, as well as a detailed description of the work practices in interventional cardiology needed in order to reconstruct the cumulative eye lens dose. The data from 69 ICs and 23 controls collected based on the general medical questionnaire and the occupational questionnaire (for ICs only) were analyzed. The mean age of ICs and of the control group was 41 and 44, respectively, while the mean duration of work for exposed physicians was 9 years. The analysis of the data from the occupational questionnaire concerning the procedures performed, the use of various access routes, as well as radiation protection tools (eye lens glasses, ceiling suspended transparent shield, etc.) are also presented. On the basis of this information and additional assumptions about the doses per procedure (as well as reduction factors for various types of radiation measures), the cumulative doses to the eye lens of ICs were evaluated. They ranged up to 1.55 Sv and 0.4 Sv for left and right eye, respectively; however, the dose to only 3% of ICs exceeded the new threshold for development of eye lens opacities (0.5 Gy) proposed by the ICRP.
- 1 July 2016
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 57 (4) , 431-437
Open AccessCharacteristics of interventional cardiologists and their work practices for the study on radiation-induced lens opacities based on the methodology developed by ELDO—preliminary results
Preliminary results of the Polish epidemiology study on eye lens opacities among interventional cardiologists (ICs), based on the methodology proposed by ELDO (epidemiological studies of radio-induced cataracts in interventional cardiologists and radiologists: methodology implementation), are presented. The aim of the study is to test the hypothesis concerning the excess risk of cataract in the group of ICs. The first results concern the study population characteristics, including the most important confounding factors for cataract, as well as a detailed description of the work practices in interventional cardiology needed in order to reconstruct the cumulative eye lens dose. The data from 69 ICs and 23 controls collected based on the general medical questionnaire and the occupational questionnaire (for ICs only) were analyzed. The mean age of ICs and of the control group was 41 and 44, respectively, while the mean duration of work for exposed physicians was 9 years. The analysis of the data from the occupational questionnaire concerning the procedures performed, the use of various access routes, as well as radiation protection tools (eye lens glasses, ceiling suspended transparent shield, etc.) are also presented. On the basis of this information and additional assumptions about the doses per procedure (as well as reduction factors for various types of radiation measures), the cumulative doses to the eye lens of ICs were evaluated. They ranged up to 1.55 Sv and 0.4 Sv for left and right eye, respectively; however, the dose to only 3% of ICs exceeded the new threshold for development of eye lens opacities (0.5 Gy) proposed by the ICRP.
- 16 May 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36 (2) , 309-318
The impact of various protective tools on the dose reduction in the eye lens in an interventional cardiology—clinical study
The aim of the study was to check, in clinical practice, the potential for the dose reduction of lead eyewear and a ceiling-suspended shield used to protect the eye lens of physicians working in interventional cardiology. To this end, for the lead eyewear, the dose reduction factors were derived to correct the readings from a dosimeter used routinely outside the glasses. Four types of lead eyewear with attached loose thermoluminescent dosimeters and EYE-D dosimeters were worn by physicians in two clinical centres, for two-month periods, during coronary angiography (CA), percutaneous coronary intervention (PCI), and pacemaker procedures. In order to analyse, separately, how a ceiling-suspended lead screen absorbs the scattered radiation, a series of measurements was carried out during single CA/PCI procedures performed with and without the protection. The lead eyewear may reduce the doses to the eye closest to the x-ray tube by a factor between 1.1 and 3.4, depending on its model and the physician’s position. The effectiveness of the eyewear may, however, vary—even for the same model and physician—almost twofold between different working periods. The ceiling-suspended shield decreases the doses in clinical practice by a factor of 2.3. The annual eye lens doses without the eyewear estimated from routine measurements are high—above or close to the new eye lens dose limit established by the recent EU Basic Safety Standards, even though the ceiling-suspended shield was used. Therefore, to comply with the new dose limit that is set in the Directive, protection of the eyes of physicians with high workloads might require the use of both the eyewear and the ceiling-suspended shield.
- 16 May 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36 (2) , 309-318
The impact of various protective tools on the dose reduction in the eye lens in an interventional cardiology—clinical study
The aim of the study was to check, in clinical practice, the potential for the dose reduction of lead eyewear and a ceiling-suspended shield used to protect the eye lens of physicians working in interventional cardiology. To this end, for the lead eyewear, the dose reduction factors were derived to correct the readings from a dosimeter used routinely outside the glasses. Four types of lead eyewear with attached loose thermoluminescent dosimeters and EYE-D dosimeters were worn by physicians in two clinical centres, for two-month periods, during coronary angiography (CA), percutaneous coronary intervention (PCI), and pacemaker procedures. In order to analyse, separately, how a ceiling-suspended lead screen absorbs the scattered radiation, a series of measurements was carried out during single CA/PCI procedures performed with and without the protection. The lead eyewear may reduce the doses to the eye closest to the x-ray tube by a factor between 1.1 and 3.4, depending on its model and the physician’s position. The effectiveness of the eyewear may, however, vary—even for the same model and physician—almost twofold between different working periods. The ceiling-suspended shield decreases the doses in clinical practice by a factor of 2.3. The annual eye lens doses without the eyewear estimated from routine measurements are high—above or close to the new eye lens dose limit established by the recent EU Basic Safety Standards, even though the ceiling-suspended shield was used. Therefore, to comply with the new dose limit that is set in the Directive, protection of the eyes of physicians with high workloads might require the use of both the eyewear and the ceiling-suspended shield.
- 29 March 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36 (2) , N19-N25
The effectiveness of lead glasses in reducing the doses to eye lenses during cardiac implantation procedures performed using x-ray tubes above the patient table
The dose reduction factors (DRF) for different types of lead glasses and C-arm units with x-ray tubes placed above the patient table were calculated from the results of measurements by loose thermoluminescent dosimeters (TLDs) and EYE-D dosimeters using a Rando phantom. The DRF values were analysed for different positions of routine dosimeters worn outside lead eyewear and confronted with DRFs calculated as the ratio of the dose equivalent to the eye measured with and without the eyewear. Moreover, for eye lens dosimeters designed to be worn behind lead glasses, multiplicative factors for various positions of dosimeter were derived in order to account for the differences between the doses measured on the inner side of the glasses and the dose equivalent to the eye lens. The DRFs calculated for the position of a routine dosimeter worn outside lead glasses on the band near the left eye lens are 5.6 and 5.7 for goggles and metallic glasses, respectively, while the DRFs calculated as the ratio of doses to the eyes measured with and without the eyewear are 10.2 and 9.9, respectively. Therefore, for dosimeters routinely used outside lead eyewear, the DRF calculated for the position of the dosimeter should be used. Otherwise, we can anticipate an almost two-fold underestimation of the doses. When the dosimeter is worn behind lead glasses, up to two-fold differences between the dose equivalent to the eye lens and the dose measured at the inner side of the glasses were observed depending on the dosimeter position.
- 29 March 2016
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 36 (2) , N19-N25
The effectiveness of lead glasses in reducing the doses to eye lenses during cardiac implantation procedures performed using x-ray tubes above the patient table
The dose reduction factors (DRF) for different types of lead glasses and C-arm units with x-ray tubes placed above the patient table were calculated from the results of measurements by loose thermoluminescent dosimeters (TLDs) and EYE-D dosimeters using a Rando phantom. The DRF values were analysed for different positions of routine dosimeters worn outside lead eyewear and confronted with DRFs calculated as the ratio of the dose equivalent to the eye measured with and without the eyewear. Moreover, for eye lens dosimeters designed to be worn behind lead glasses, multiplicative factors for various positions of dosimeter were derived in order to account for the differences between the doses measured on the inner side of the glasses and the dose equivalent to the eye lens. The DRFs calculated for the position of a routine dosimeter worn outside lead glasses on the band near the left eye lens are 5.6 and 5.7 for goggles and metallic glasses, respectively, while the DRFs calculated as the ratio of doses to the eyes measured with and without the eyewear are 10.2 and 9.9, respectively. Therefore, for dosimeters routinely used outside lead eyewear, the DRF calculated for the position of the dosimeter should be used. Otherwise, we can anticipate an almost two-fold underestimation of the doses. When the dosimeter is worn behind lead glasses, up to two-fold differences between the dose equivalent to the eye lens and the dose measured at the inner side of the glasses were observed depending on the dosimeter position.
- 28 January 2013
- Published by Elsevier in Radiation Measurements
- Vol. 51-52, 62-66
A study on the dose distributions near the eye lens and the legs. Part 2 – Interventional radiology
- 28 January 2013
- Published by Elsevier in Radiation Measurements
- Vol. 51-52, 62-66
A study on the dose distributions near the eye lens and the legs. Part 2 – Interventional radiology
- 29 February 2012
- Published by Elsevier in Radiation Measurements
- Vol. 47 (2) , 130-138
A study of the dose distribution in the region of the eye lens and extremities for staff working in interventional cardiology
- 29 February 2012
- Published by Elsevier in Radiation Measurements
- Vol. 47 (2) , 130-138
A study of the dose distribution in the region of the eye lens and extremities for staff working in interventional cardiology
- 23 December 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 442-447
Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED project
The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.
- 23 December 2010
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 144 (1-4) , 442-447
Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED project
The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.