Safety of closed‐loop therapy during reduction or omission of meal boluses in adolescents with type 1 diabetes: a randomized clinical trial
- 6 June 2014
- journal article
- research article
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 16 (11) , 1174-1178
Abstract
We evaluated the safety and efficacy of closed‐loop therapy with meal announcement during reduction and omission of meal insulin boluses in adolescents with type 1 diabetes ( T1D ). Twelve adolescents with T1D [six male; mean (s.d.) age 15.9 (1.8) years; mean (s.d.) glycated haemoglobin ( HbA1c ) 77 (27) mmol/mol] were studied in a randomized crossover study comparing closed‐loop therapy with meal announcement with conventional pump therapy over two 24‐h stays at a clinical research facility. Identical meals were given on both occasions. The evening meal insulin bolus was calculated to cover half of the carbohydrate content of the meal and no bolus was delivered for lunch. Plasma glucose levels were in the target range of 3.9–10 mmol/l for a median [interquartile range ( IQR )] of 74 (55,86)% of the time during closed‐loop therapy with meal announcement and for 62 (49,75)% of the time during conventional therapy (p = 0.26). Median ( IQR ) time spent with plasma glucose levels > 10 mmol/l [23 (13,39) vs. 27 (10,50)%; p = 0.88] or < 3.9 mmol/l [1(0,4) vs. 5 (1,10)%; p = 0.24] and mean [standard deviation (SD)] glucose levels [8.0 (7.6,9.3) vs. 7.7 (6.6,10.1) mmol/l, p = 0.79] were also similar. In conclusion, these results assist home testing of closed‐loop delivery with meal announcement in adolescents with poorly controlled T1D who miscalculate or miss meal insulin boluses.Keywords
Funding Information
- US National Institute of Diabetes and Digestive and Kidney Diseases (1R01DK085621)
This publication has 11 references indexed in Scilit:
- Closed-Loop Basal Insulin Delivery Over 36 Hours in Adolescents With Type 1 DiabetesDiabetes Care, 2013
- Closed-loop insulin delivery for treatment of type 1 diabetesBMC Medicine, 2011
- Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trialThe Lancet, 2010
- Missed Insulin Boluses for Snacks in Youth With Type 1 DiabetesDiabetes Care, 2009
- Closed-Loop Artificial Pancreas Using Subcutaneous Glucose Sensing and Insulin Delivery and a Model Predictive Control Algorithm: Preliminary Studies in Padova and MontpellierJournal of Diabetes Science and Technology, 2009
- Missed bolus doses: devastating for metabolic control in CSII-treated adolescents with type 1 diabetesPediatric Diabetes, 2009
- Fully Automated Closed-Loop Insulin Delivery Versus Semiautomated Hybrid Control in Pediatric Patients With Type 1 Diabetes Using an Artificial PancreasDiabetes Care, 2008
- Feasibility of Automating Insulin Delivery for the Treatment of Type 1 DiabetesDiabetes, 2006
- Missed Insulin Meal Boluses and Elevated Hemoglobin A1c Levels in Children Receiving Insulin Pump TherapyPediatrics, 2004
- Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: Diabetes Control and Complications TrialThe Journal of Pediatrics, 1994