Change in composition of blood after passing through circuit of automated device versus manual clinical method for neonatal exchange transfusions
Authors:
- Sourabh DuttaSDSourabh Dutta
- Neha SharmaNSNeha Sharma
- Suchet SachdevSSSuchet Sachdev
- Ratti Ram SharmaRSRatti Ram Sharma
- Sanjeev VermaSVSanjeev Verma
- Arindam ChatterjeeACArindam Chatterjee
- Prateek BhatiaPBPrateek Bhatia
- Savita AttriSASavita Attri
- Archana AngrupAAArchana Angrup
- Sarbjeet SinghSSSarbjeet Singh
- Gurinderjit SinghGSGurinderjit Singh
- Praveen KumarPKPraveen Kumar
- 22 December 2025
- journal article
- research article
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 185 (1) , 32
Abstract
We previously developed and published a novel device to automate double volume exchange transfusions (DVET) via the umbilical venous catheter (UVC) in neonates. Prior to initiating clinical trials, we aimed to demonstrate that alterations in blood composition after passage through our device’s circuit were not greater than those seen with the conventional manual method. We performed five ex vivo simulations of neonatal DVET using donor blood in standard blood bank bags and our automated device. Samples were obtained from the blood bag at baseline and from the distal end of the circuit after completion of 50% and 100% of the simulated DVET. These were analyzed for hematological, biochemical, and blood gas parameters, osmolality, and culture. For comparison, four manual DVETs were similarly performed, with corresponding sample collection and analyses. Deviations of laboratory parameters at the 50% and 100% time points that were > ± 25% from baseline were classified as major. The proportion of major deviations was compared between automated and manual DVETs. Automated DVETs demonstrated significantly fewer major deviations than manual DVETs in hematological parameters [15/156 (9.61%) vs. 28/124 (22.58%), p = 0.0048], biochemical parameters [0/120 (0%) vs. 32/88 (36.36%), p < 0.0001], and blood gas values [11/50 (22.0%) vs. 20/40 (50.0%), p = 0.011]. Notably, the blood used in automated DVETs was significantly older than that used in the manual group. Conclusion: Automated DVET using our novel device results in fewer compositional deviations from baseline compared to conventional manual DVET, supporting its potential clinical utility. What is Known: • Our research group previously developed and published a novel electromechanical device to perform double volume exchange transfusions (DVET) in neonates through the umbilical venous route. • Previous authors who had made automated devices did not analyze the composition of the blood exiting the device circuit (“post-circuit” composition), nor compared this to the conventional manual method of exchange transfusions. What is New: • In simulated DVETs performed with our device, there were significantly fewer changes in the post-circuit composition of the blood from baseline (hematological, biochemical, blood gas and osmolality values) compared to manual DVETs. • Among DVETs performed manually, 7 ml aliquots per cycle were associated with greater changes in the post-circuit composition of the blood compared to 10 ml aliquots per cycle.Keywords
Funding Information
- Department of Health Research, India (R.11013/12/2021-GIA/HR dated 13-Sep-2021)
This publication has 21 references indexed in Scilit:
- Novel device for automating exchange transfusions through umbilical venous route in neonatesEuropean Journal of Pediatrics, 2023
- Fully automated simultaneous peripheral arteriovenous exchange transfusion not seen to aggravate brain function and the disorder of the internal environment in neonates with severe hyperbilirubinemiaPediatrics & Neonatology, 2021
- Neonatal management and outcome in alloimmune hemolytic diseaseExpert Review of Hematology, 2017
- Is fully automated simultaneous umbilical arteriovenous exchange transfusion safe enough?The Journal of Maternal-Fetal & Neonatal Medicine, 2016
- Effect of Fresh Red Blood Cell Transfusions on Clinical Outcomes in Premature, Very Low-Birth-Weight InfantsJAMA, 2012
- Washing of irradiated red blood cells prevents hyperkalaemia during cardiopulmonary bypass in neonates and infants undergoing surgery for complex congenital heart diseaseEuropean Journal of Cardio-Thoracic Surgery, 2007
- Automated apparatus for exchange transfusionThe Journal of Pediatrics, 1984
- Automated method for exchange transfusion: A new modificationThe Journal of Pediatrics, 1983
- Does transfusion using a syringe infusion pump and small‐gauge needle cause hemolysis?Transfusion, 1981
- Erythroblastosis FetalisNew England Journal of Medicine, 1951