Reproducibility assessment of a multiple reference tissue method for quantitative dynamic contrast enhanced–MRI analysis
Authors:
Open Access
- 30 January 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 61 (4) , 851-859
Abstract
Bone metastases of 16 prostate cancer patients were scanned twice 1 week apart by dynamic contrast enhanced (DCE) –MRI at 2‐s resolution using a two‐dimensional gradient‐echo pulse sequence. With a multiple reference tissue method (MRTM), the local tissue arterial input function (AIF) was estimated using the contrast agent enhancement data from tumor subregions and muscle. The 32 individual AIFs estimated by the MRTM, which had considerable intra‐patient and inter‐patient variability, were similar to directly measured AIFs in the literature and using the MRTM AIFs in a pharmacokinetic model to derive estimated individual cardiac outputs provided physiologically reasonable results. The MRTM individual AIFs gave better fits with smaller sum of squared errors and equally reproducible estimate of kinetic parameters compared with a previous reported population AIF measured from remote arteries. The individual MRTM AIFs were also used to obtain a mean local tissue AIF for the unique population of this study, which further improved the reproducibility of the estimated kinetic parameters. The MRTM can be applied to DCE‐MRI studies of bone metastases from prostate cancers to provide an AIF from which reproducible quantitative DCE‐MRI parameters can be derived, thus help standardize DCE‐MRI studies in cancer patients. Magn Reson Med, 2009.Keywords
This publication has 37 references indexed in Scilit:
- Incorporating the effects of transcytolemmal water exchange in a reference region model for DCE‐MRI analysis: Theory, simulations, and experimental resultsMagnetic Resonance in Medicine, 2008
- Reproducibility of reference tissue quantification of dynamic contrast-enhanced data: comparison with a fixed vascular input functionPhysics in Medicine & Biology, 2006
- Experimentally‐derived functional form for a population‐averaged high‐temporal‐resolution arterial input function for dynamic contrast‐enhanced MRIMagnetic Resonance in Medicine, 2006
- A unified magnetic resonance imaging pharmacokinetic theory: Intravascular and extracellular contrast reagentsMagnetic Resonance in Medicine, 2005
- The impact of partial‐volume effects in dynamic susceptibility contrast magnetic resonance perfusion imagingJournal of Magnetic Resonance Imaging, 2005
- Estimating the arterial input function using two reference tissues in dynamic contrast‐enhanced MRI studies: Fundamental concepts and simulationsMagnetic Resonance in Medicine, 2004
- Estimation of kinetic parameters without input functions: analysis of three methods for multichannel blind identificationIEEE Transactions on Biomedical Engineering, 2002
- Segmentation of dynamic PET images using cluster analysisIEEE Transactions on Nuclear Science, 2002
- Inversion recovery EPI of bolus transit in rat myocardium using intravascular and extravascular gadolinium‐based MR contrast media: Dose effects on peak signal enhancementMagnetic Resonance in Medicine, 1994
- Measurement of cardiac output by cine computed tomographyThe American Journal of Cardiology, 1985