Potential for occupational exposures to pathogens during bronchoscopy procedures
- 13 August 2019
- journal article
- research article
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 16 (10) , 707-716
Abstract
Bronchoscopy is classified as an aerosol-generating procedure, but it is unclear what drives the elevated infection risk observed among healthcare personnel performing the procedure. The objective of this study was to characterize pathways through which bronchoscopists may be exposed to infectious agents during bronchoscopy procedures. Aerosol number concentrations (0.2–1 µm aerodynamic diameter) were measured using a P-Trak Ultrafine Particle Counter 8525 and mass concentrations (<10 µm) were measured using a SidePak Personal Aerosol Monitor AM510 near the head of patients during bronchoscopy procedures. Procedure pathway, number of patient coughs, number of suctioning events, number of contacts with different surfaces by the pulmonologist, and the use and doffing of personal protective equipment were recorded by the investigator on a specially designed form. Any pulmonologist performing a bronchoscopy procedure was eligible to participate. A total of 18 procedures were observed. Mean particle number and mass concentrations were not elevated during procedures relative to those measured before or after the procedure, on average, but the concentrations were highly variable, exhibiting high levels periodically. Patients frequently coughed during procedures (median 65 coughs, range: 0–565 coughs), and suctioning was commonly performed (median 6.5 suctioning events, range: 0–42). In all procedures, pulmonologists contacted the patient (mean 22.3 contacts, range: 1–48), bronchoscope (mean 19.4 contacts, range: 1–46), and at least one environmental surface (mean 31.2 contacts, range: 3–62). In the majority of procedures, the participant contacted his or her body or personal protective equipment (PPE), with a mean of 17.3 contacts (range: 4–48). More often than not, the observed PPE doffing practices differed from those recommended. Bronchoscopy procedures were associated with short-term increased ultrafine or respirable aerosol concentrations, and there were opportunities for contact transmission.Keywords
This publication has 10 references indexed in Scilit:
- Characterization of Aerosols Generated During Patient Care ActivitiesClinical Infectious Diseases, 2017
- Assessment of Healthcare Worker Protocol Deviations and Self-Contamination During Personal Protective Equipment Donning and DoffingInfection Control & Hospital Epidemiology, 2017
- Lowered Rilpivirine Exposure During the Third Trimester of Pregnancy in Human Immunodeficiency Virus Type 1–Infected WomenClinical Infectious Diseases, 2017
- Aerosol Transmission of Infectious DiseaseJournal of Occupational and Environmental Medicine, 2015
- Evaluation of bioaerosol exposures during hospital bronchoscopy examinationsEnvironmental Science: Processes & Impacts, 2014
- Are health care workers protected? An observational study of selection and removal of personal protective equipment in Canadian acute care hospitalsAmerican Journal of Infection Control, 2013
- Influenza Aerosols in UK Hospitals during the H1N1 (2009) Pandemic – The Risk of Aerosol Generation during Medical ProceduresPLOS ONE, 2013
- 2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care SettingsAmerican Journal of Infection Control, 2007
- Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable PathogensJournal of Occupational and Environmental Hygiene, 2005
- Dissemination of Respiratory Secretions During Tracheal Tube Suctioning in an Intensive Care UnitAnnals of the Academy of Medicine, Singapore, 1999