LPLinh T. Phan

Linh T. Phan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Linh T. Phan has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Prácticas de retiro del equipo de protección personal para personal sanitario

    by Linh T. Phan, Dayana Maita, Donna C. Mortiz, Rachel Weber, Charissa Fritzen-Pedicini, Susan C. Bleasdale, Rachael M. Jones, Para el Programa de Epicentros de Prevención de Los Cdc

    RESUMEN Cuando se retira el equipo de protección personal (EPP), los patógenos pueden transferirse desde el EPP al cuerpo de los trabajadores de la salud, poniendo en riesgo de exposición e infección tanto a ellos mismos como a sus pacientes. Entre marzo de 2017 y abril de 2018 se observaron las prácticas de retirada del EPP del personal sanitario que atendía pacientes con infecciones respiratorias virales en un hospital de atención de enfermedades agudas. Un observador capacitado registró el desempeño del personal sanitario cuando retiraba el EPP dentro de las habitaciones de los pacientes, utilizando una lista de verificación predefinida basada en las directrices de los Centros para el Control y Prevención de Enfermedades (Centers for Disease Control and Prevention, CDC). Se observaron 162 prácticas de retirada durante el cuidado de 52 pacientes infectados con patógenos virales respiratorios. De estos 52 pacientes, 30 estaban en aislamiento por gota y contacto, 21 en aislamiento por gota y uno en aislamiento de contacto. En general, en 90% de los casos la retirada del EPP observada se realizó de manera incorrecta, ya sea en cuanto a la secuencia de retirada, la técnica de retirada o el uso del EPP apropiado. Los errores más comunes consistieron en quitarse la bata por adelante, retirar la pantalla facial de la mascarilla y tocar superficies y EPP potencialmente contaminados durante el proceso. Las desviaciones del protocolo recomendado para retirar el EPP son comunes y pueden aumentar el potencial de contaminación de la ropa o la piel del personal sanitario después de proporcionar atención. Existe una clara necesidad de cambiar el enfoque utilizado para capacitar al personal en las prácticas de retirada del EPP.


  • Respiratory viruses in the patient environment

    by Linh T. Phan, Dagmar M. Sweeney, Dayana Maita, Donna C. Moritz, Susan C. Bleasdale, Rachael M. Jones, For The Cdc Prevention Epicenters Program

    Objective: To characterize the presence and magnitude of viruses in the air and on surfaces in the rooms of hospitalized patients with respiratory viral infections, and to explore the association between care activities and viral contamination.Design: Prospective observational study.Setting: Acute-care academic hospital.Participants: In total, 52 adult patients with a positive respiratory viral infection test within 3 days of observation participated. Healthcare workers (HCWs) were recruited in staff meetings and at the time of patient care, and 23 wore personal air-sampling devices.Methods: Viruses were measured in the air at a fixed location and in the personal breathing zone of HCWs. Predetermined environmental surfaces were sampled using premoistened Copan swabs at the beginning and at the end of the 3-hour observation period. Preamplification and quantitative real-time PCR methods were used to quantify viral pathogens.Results: Overall, 43% of stationary and 22% of personal air samples were positive for virus. Positive stationary air samples were associated with ≥5 HCW encounters during the observation period (odds ratio [OR], 5.3; 95% confidence interval [CI], 1.2–37.8). Viruses were frequently detected on all of the surfaces sampled. Virus concentrations on the IV pole hanger and telephone were positively correlated with the number of contacts made by HCWs on those surfaces. The distributions of influenza, rhinoviruses, and other viruses in the environment were similar.Conclusions: Healthcare workers are at risk of contracting respiratory virus infections when delivering routine care for patients infected with the viruses, and they are at risk of disseminating virus because they touch virus-contaminated fomites.


  • Respiratory viruses on personal protective equipment and bodies of healthcare workers

    by Linh T. Phan, Dagmar Sweeney, Dayana Maita, Donna C. Moritz, Susan C. Bleasdale, Rachael M. Jones, For The Cdc Prevention Epicenters Program

    Objective: To characterize the magnitude of virus contamination on personal protective equipment (PPE), skin, and clothing of healthcare workers (HCWs) who cared for patients having acute viral infections.Design: Prospective observational study.Setting: Acute-care academic hospital.Participants: A total of 59 HCWs agreed to have their PPE, clothing, and/or skin swabbed for virus measurement.Methods: The PPE worn by HCW participants, including glove, face mask, gown, and personal stethoscope, were swabbed with Copan swabs. After PPE doffing, bodies and clothing of HCWs were sampled with Copan swabs: hand, face, and scrubs. Preamplification and quantitative polymerase chain reaction (qPCR) methods were used to quantify viral RNA copies in the swab samples.Results: Overall, 31% of glove samples, 21% of gown samples, and 12% of face mask samples were positive for virus. Among the body and clothing sites, 21% of bare hand samples, 11% of scrub samples, and 7% of face samples were positive for virus. Virus concentrations on PPE were not statistically significantly different than concentrations on skin and clothing under PPE. Virus concentrations on the personal stethoscopes and on the gowns were positively correlated with the number of torso contacts (P < .05). Virus concentrations on face masks were positively correlated with the number of face mask contacts and patient contacts (P < .05).Conclusions: Healthcare workers are routinely contaminated with respiratory viruses after patient care, indicating the need to ensure that HCWs complete hand hygiene and use other PPE to prevent dissemination of virus to other areas of the hospital. Modifying self-contact behaviors may decrease the presence of virus on HCWs.


  • Open Access

    Environmental Contact and Self-contact Patterns of Healthcare Workers: Implications for Infection Prevention and Control

    by Linh T Phan, Dayana Maita, Donna C Mortiz, Susan C Bleasdale, Rachael M Jones

    Respiratory viruses on fomites can be transferred to sites susceptible to infection via contact by hands or other fomites. Care for hospitalized patients with viral respiratory infections was observed in the patient room for 3-hour periods at an acute care academic medical center for over a 2 year period. One trained observer recorded the healthcare activities performed, contacts with fomites, and self-contacts made by healthcare workers (HCWs), while another observer recorded fomite contacts of patients during the encounter using predefined checklists. The surface contacted by HCWs during the majority of visits was the patient (90%). Environmental surfaces contacted by HCWs frequently during healthcare activities included the tray table (48%), bed surface (41%), bed rail (41%), computer station (37%), and intravenous pole (32%). HCWs touched their own torso and mask in 32% and 29% of the visits, respectively. HCWs’ self-contacts differed significantly among HCW job roles, with providers and respiratory therapists contacting themselves significantly more times than nurses and nurse technicians (P < .05). When HCWs performed only 1 care activity, there were significant differences in the number of patient contacts and self-contacts that HCWs made during performance of multiple care activities (P < .05). HCWs regularly contact environmental surfaces, patients, and themselves while providing care to patients with infectious diseases, varying among care activities and HCW job roles. These contacts may facilitate the transmission of infection to HCWs and susceptible patients.


  • Potential for occupational exposures to pathogens during bronchoscopy procedures

    by Maryshe Zietsman, Linh T. Phan, Rachael M. Jones

    Bronchoscopy is classified as an aerosol-generating procedure, but it is unclear what drives the elevated infection risk observed among healthcare personnel performing the procedure. The objective of this study was to characterize pathways through which bronchoscopists may be exposed to infectious agents during bronchoscopy procedures. Aerosol number concentrations (0.2–1 µm aerodynamic diameter) were measured using a P-Trak Ultrafine Particle Counter 8525 and mass concentrations (<10 µm) were measured using a SidePak Personal Aerosol Monitor AM510 near the head of patients during bronchoscopy procedures. Procedure pathway, number of patient coughs, number of suctioning events, number of contacts with different surfaces by the pulmonologist, and the use and doffing of personal protective equipment were recorded by the investigator on a specially designed form. Any pulmonologist performing a bronchoscopy procedure was eligible to participate. A total of 18 procedures were observed. Mean particle number and mass concentrations were not elevated during procedures relative to those measured before or after the procedure, on average, but the concentrations were highly variable, exhibiting high levels periodically. Patients frequently coughed during procedures (median 65 coughs, range: 0–565 coughs), and suctioning was commonly performed (median 6.5 suctioning events, range: 0–42). In all procedures, pulmonologists contacted the patient (mean 22.3 contacts, range: 1–48), bronchoscope (mean 19.4 contacts, range: 1–46), and at least one environmental surface (mean 31.2 contacts, range: 3–62). In the majority of procedures, the participant contacted his or her body or personal protective equipment (PPE), with a mean of 17.3 contacts (range: 4–48). More often than not, the observed PPE doffing practices differed from those recommended. Bronchoscopy procedures were associated with short-term increased ultrafine or respirable aerosol concentrations, and there were opportunities for contact transmission.


  • Top Cited Papers

    Personal protective equipment doffing practices of healthcare workers

    by Linh T. Phan, Dayana Maita, Donna C. Mortiz, Rachel Weber, Charissa Fritzen-Pedicini, Susan C. Bleasdale, Rachael M. Jones, For The Cdc Prevention Epicenters Program

    During the doffing of personal protective equipment (PPE), pathogens can be transferred from the PPE to the bodies of healthcare workers (HCWs), putting HCWs and patients at risk of exposure and infection. PPE doffing practices of HCWs who cared for patients with viral respiratory infections were observed at an acute care hospital from March 2017 to April 2018. A trained observer recorded doffing performance of HCWs inside the patient rooms using a pre-defined checklist based on the Centers for Disease Control and Prevention (CDC) guideline. Doffing practices were observed 162 times during care of 52 patients infected with respiratory viral pathogens. Out of the 52 patients, 30 were in droplet and contact isolation, 21 were in droplet isolation, and 1 was in contact isolation. Overall, 90% of observed doffing was incorrect, with respect to the doffing sequence, doffing technique, or use of appropriate PPE. Common errors were doffing gown from the front, removing face shield of the mask, and touching potentially contaminated surfaces and PPE during doffing. Deviations from the recommended PPE doffing protocol are common and can increase potential for contamination of the HCW’s clothing or skin after providing care. There is a clear need to change the approach used to training HCWs in PPE doffing practices.


  • Environmental and Personal Protective Equipment Contamination during Simulated Healthcare Activities

    by Rachel T Weber, Linh T Phan, Charissa Fritzen-Pedicini, Rachael M Jones

    Providing care to patients with an infectious disease can result in the exposure of healthcare workers (HCWs) to pathogen-containing bodily fluids. We performed a series of experiments to characterize the magnitude of environmental contamination—in air, on surfaces and on participants—associated with seven common healthcare activities. The seven activities studied were bathing, central venous access, intravenous access, intubation, physical examination, suctioning and vital signs assessment. HCWs with experience in one or more activities were recruited to participate and performed one to two activities in the laboratory using task trainers that contained or were contaminated with fluorescein-containing simulated bodily fluid. Fluorescein was quantitatively measured in the air and on seven environmental surfaces. Fluorescein was quantitatively and qualitatively measured on the personal protective equipment (PPE) worn by participants. A total of 39 participants performed 74 experiments, involving 10–12 experimental trials for each healthcare activity. Healthcare activities resulted in diverse patterns and levels of contamination in the environment and on PPE that are consistent with the nature of the activity. Glove and gown contamination were ubiquitous, affirming the value of wearing these pieces of PPE to protect HCW’s clothing and skin. Though intubation and suctioning are considered aerosol-generating procedures, fluorescein was detected less frequently in air and at lower levels on face shields and facemasks than other activities, which suggests that the definition of aerosol-generating procedure may need to be revised. Face shields may protect the face and facemask from splashes and sprays of bodily fluids and should be used for more healthcare activities.


  • Open Access

    Personal Protective Equipment Doffing Practices of Health Care Workers

    by Linh T. Phan, Donna C. Moritz, Rachel T. Weber, Susan C. Bleasdale, Rachael Jones


  • Open Access

    Environmental and Personal Protective Equipment Contamination During Simulated Healthcare Activities

    by Rachel T. Weber, Linh T. Phan, Osayuwamen Edomwande, Charissa M. Fritzen-Pedicini, Susan C. Bleasdale, Rachael Jones


  • Environmental and body contamination from cleaning vomitus in a health care setting: A simulation study

    by Linh Phan, Yu-Min Su, Rachel Weber, Charissa Fritzen-Pedicini, Osayuwamen Edomwande, Rachael M. Jones