Complications after Surgical Procedures in Patients with Cardiac Implantable Electronic Devices: Results of a Prospective Registry
Authors:
- Katia Regina da SilvaKatia Regina da Silva
- Martino Martinelli FilhoMFMartino Martinelli Filho
- Roberto CostaRCRoberto Costa
Open Access
- 1 January 2016
- journal article
- Published by Sociedade Brasileira de Cardiologia in Arquivos Brasileiros de Cardiologia
- Vol. 107 (3) , 245-256
Abstract
Complications after surgical procedures in patients with cardiac implantable electronic devices (CIED) are an emerging problem due to an increasing number of such procedures and aging of the population, which consequently increases the frequency of comorbidities. To identify the rates of postoperative complications, mortality, and hospital readmissions, and evaluate the risk factors for the occurrence of these events. Prospective and unicentric study that included all individuals undergoing CIED surgical procedures from February to August 2011. The patients were distributed by type of procedure into the following groups: initial implantations (cohort 1), generator exchange (cohort 2), and lead-related procedures (cohort 3). The outcomes were evaluated by an independent committee. Univariate and multivariate analyses assessed the risk factors, and the Kaplan-Meier method was used for survival analysis. A total of 713 patients were included in the study and distributed as follows: 333 in cohort 1, 304 in cohort 2, and 76 in cohort 3. Postoperative complications were detected in 7.5%, 1.6%, and 11.8% of the patients in cohorts 1, 2, and 3, respectively (p = 0.014). During a 6-month follow-up, there were 58 (8.1%) deaths and 75 (10.5%) hospital readmissions. Predictors of hospital readmission included the use of implantable cardioverter-defibrillators (odds ratio [OR] = 4.2), functional class III-IV (OR = 1.8), and warfarin administration (OR = 1.9). Predictors of mortality included age over 80 years (OR = 2.4), ventricular dysfunction (OR = 2.2), functional class III-IV (OR = 3.3), and warfarin administration (OR = 2.3). Postoperative complications, hospital readmissions, and deaths occurred frequently and were strongly related to the type of procedure performed, type of CIED, and severity of the patient's underlying heart disease.Keywords
This publication has 25 references indexed in Scilit:
- Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractionsHeart Rhythm, 2014
- Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in DenmarkEuropean Heart Journal, 2013
- Glocal Clinical Registries: Pacemaker Registry Design and Implementation for Global and Local Integration – Methodology and Case StudyPLOS ONE, 2013
- 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: The Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA)EP Europace, 2013
- Survival of Patients Receiving a Primary Prevention Implantable Cardioverter-Defibrillator in Clinical Practice vs Clinical TrialsJAMA, 2013
- 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United StatesJACC, 2011
- The Relation Between Hospital Procedure Volume and Complications of Cardioverter-Defibrillator Implantation From the Implantable Cardioverter-Defibrillator RegistryJACC, 2010
- Recurrent Implantable Cardioverter-Defibrillator Replacement Is Associated with an Increasing Risk of Pocket-Related ComplicationsPacing and Clinical Electrophysiology, 2010
- Research electronic data capture (REDCap)—A metadata-driven methodology and workflow process for providing translational research informatics supportJournal of Biomedical Informatics, 2009
- The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart FailureThe New England journal of medicine, 2005