4D Flow MRI in Ascending Aortic Aneurysms: Reproducibility of Hemodynamic Parameters
Authors:
- Joe F. JuffermansJJJoe F. Juffermans
- Hans C. van AssenHAHans C. van Assen
- Bastiaan J. C. Te KiefteBKBastiaan J. C. Te Kiefte
- Mitch J. F. G. RamaekersMRMitch J. F. G. Ramaekers
- Roel L. F. van der PalenRPRoel L. F. van der Palen
- Pieter van Den BoogaardPBPieter van Den Boogaard
- Bouke P. AdriaansBABouke P. Adriaans
- Joachim E. WildbergerJWJoachim E. Wildberger
- Ilona A. DekkersIDIlona A. Dekkers
- Arthur J. H. A. ScholteASArthur J. H. A. Scholte
- Simon SchallaSSSimon Schalla
- Hildo J. LambHLHildo J. Lamb
Open Access
- 13 April 2022
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 12 (8) , 3912
Abstract
(1) Background: Aorta hemodynamics have been associated with aortic remodeling, but the reproducibility of its assessment has been evaluated marginally in patients with thoracic aortic aneurysm (TAA). The current study evaluated intra- and interobserver reproducibility of 4D flow MRI-derived hemodynamic parameters (normalized flow displacement, flow jet angle, wall shear stress (WSS) magnitude, axial WSS, circumferential WSS, WSS angle, vorticity, helicity, and local normalized helicity (LNH)) in TAA patients; (2) Methods: The thoracic aorta of 20 patients was semi-automatically segmented on 4D flow MRI data in 5 systolic phases by 3 different observers. Each time-dependent segmentation was manually improved and partitioned into six anatomical segments. The hemodynamic parameters were quantified per phase and segment. The coefficient of variation (COV) and intraclass correlation coefficient (ICC) were calculated; (3) Results: A total of 2400 lumen segments were analyzed. The mean aneurysm diameter was 50.8 ± 2.7 mm. The intra- and interobserver analysis demonstrated a good reproducibility (COV = 16–30% and ICC = 0.84–0.94) for normalized flow displacement and jet angle, a very good-to-excellent reproducibility (COV = 3–26% and ICC = 0.87–1.00) for all WSS components, helicity and LNH, and an excellent reproducibility (COV = 3–10% and ICC = 0.96–1.00) for vorticity; (4) Conclusion: 4D flow MRI-derived hemodynamic parameters are reproducible within the thoracic aorta in TAA patients.Keywords
Funding Information
- Hartstichting (CVON2017-08-RADAR)
This publication has 38 references indexed in Scilit:
- Aortic Dilation in Bicuspid Aortic Valve DiseaseCirculation: Cardiovascular Imaging, 2013
- 4D flow magnetic resonance imaging in bicuspid aortic valve disease demonstrates altered distribution of aortic blood flow helicityMagnetic Resonance in Medicine, 2013
- Assessment of the accuracy of MRI wall shear stress estimation using numerical simulationsJournal of Magnetic Resonance Imaging, 2012
- Comparison of four‐dimensional flow parameters for quantification of flow eccentricity in the ascending aortaJournal of Magnetic Resonance Imaging, 2011
- Indications for Ascending Aortic ReplacementJACC, 2011
- Reproducibility of flow and wall shear stress analysis using flow‐sensitive four‐dimensional MRIJournal of Magnetic Resonance Imaging, 2011
- Hemodynamic predictors of aortic dilatation in bicuspid aortic valve by velocity-encoded cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2010
- Aortic Diameter ≥5.5 cm Is Not a Good Predictor of Type A Aortic DissectionCirculation, 2007
- Novel Measurement of Relative Aortic Size Predicts Rupture of Thoracic Aortic AneurysmsThe Annals of Thoracic Surgery, 2006
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986