Pieter J. van Den Boogaard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Pieter J. van Den Boogaard has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Hildo Lamb
Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
2 shared publications - Arno A. W. Roest
Department of Pediatric Cardiology, Leiden University Medical Center, Leiden, The Netherlands
1 shared publication - Arthur J. H. A. Scholte
Department of Cardiology, Leiden University Medical Center, 2333 ZA Leiden, The Netherlands
1 shared publication - Bastiaan J. C. Te Kiefte
Cardio Vascular Imaging Group (CVIG), Leiden University Medical Center (LUMC), Leiden, The Netherlands.
1 shared publication - Bouke P. Adriaans
Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht (CARIM) , P. Debyelaan 25, Maastricht, HX 6229
1 shared publication - Hans C. van Assen
Department of Radiology Leiden University Medical Center Leiden The Netherlands
1 shared publication
Latest Publications
- Open Access
- 13 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (8) , 3912
4D Flow MRI in Ascending Aortic Aneurysms: Reproducibility of Hemodynamic Parameters
(1) Background: Aorta hemodynamics have been associated with aortic remodeling, but the reproducibility of its assessment has been evaluated marginally in patients with thoracic aortic aneurysm (TAA). The current study evaluated intra- and interobserver reproducibility of 4D flow MRI-derived hemodynamic parameters (normalized flow displacement, flow jet angle, wall shear stress (WSS) magnitude, axial WSS, circumferential WSS, WSS angle, vorticity, helicity, and local normalized helicity (LNH)) in TAA patients; (2) Methods: The thoracic aorta of 20 patients was semi-automatically segmented on 4D flow MRI data in 5 systolic phases by 3 different observers. Each time-dependent segmentation was manually improved and partitioned into six anatomical segments. The hemodynamic parameters were quantified per phase and segment. The coefficient of variation (COV) and intraclass correlation coefficient (ICC) were calculated; (3) Results: A total of 2400 lumen segments were analyzed. The mean aneurysm diameter was 50.8 ± 2.7 mm. The intra- and interobserver analysis demonstrated a good reproducibility (COV = 16–30% and ICC = 0.84–0.94) for normalized flow displacement and jet angle, a very good-to-excellent reproducibility (COV = 3–26% and ICC = 0.87–1.00) for all WSS components, helicity and LNH, and an excellent reproducibility (COV = 3–10% and ICC = 0.96–1.00) for vorticity; (4) Conclusion: 4D flow MRI-derived hemodynamic parameters are reproducible within the thoracic aorta in TAA patients.
- 13 April 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (8) , 3912
Open Access4D Flow MRI in Ascending Aortic Aneurysms: Reproducibility of Hemodynamic Parameters
(1) Background: Aorta hemodynamics have been associated with aortic remodeling, but the reproducibility of its assessment has been evaluated marginally in patients with thoracic aortic aneurysm (TAA). The current study evaluated intra- and interobserver reproducibility of 4D flow MRI-derived hemodynamic parameters (normalized flow displacement, flow jet angle, wall shear stress (WSS) magnitude, axial WSS, circumferential WSS, WSS angle, vorticity, helicity, and local normalized helicity (LNH)) in TAA patients; (2) Methods: The thoracic aorta of 20 patients was semi-automatically segmented on 4D flow MRI data in 5 systolic phases by 3 different observers. Each time-dependent segmentation was manually improved and partitioned into six anatomical segments. The hemodynamic parameters were quantified per phase and segment. The coefficient of variation (COV) and intraclass correlation coefficient (ICC) were calculated; (3) Results: A total of 2400 lumen segments were analyzed. The mean aneurysm diameter was 50.8 ± 2.7 mm. The intra- and interobserver analysis demonstrated a good reproducibility (COV = 16–30% and ICC = 0.84–0.94) for normalized flow displacement and jet angle, a very good-to-excellent reproducibility (COV = 3–26% and ICC = 0.87–1.00) for all WSS components, helicity and LNH, and an excellent reproducibility (COV = 3–10% and ICC = 0.96–1.00) for vorticity; (4) Conclusion: 4D flow MRI-derived hemodynamic parameters are reproducible within the thoracic aorta in TAA patients.
- Open Access
- 1 January 2019
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 21 (1) , 43-11
Stress increases intracardiac 4D flow cardiovascular magnetic resonance -derived energetics and vorticity and relates to VO2max in Fontan patients
- 1 January 2019
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 21 (1) , 43-11
Open AccessStress increases intracardiac 4D flow cardiovascular magnetic resonance -derived energetics and vorticity and relates to VO2max in Fontan patients