Novel coincidence detection technique for precision measurement of neutron capture-induced nuclear recoils
Open Access
- 3 October 2025
- journal article
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (7)
Abstract
The lattice dynamics following particle interactions remain not fully understood, and effects from nuclear-recoil interactions in conventional solid-state detectors—such as defect formation—can hinder accurate event-energy interpretation. Neutron capture ( n , γ ) can produce detectable, precise-energy nuclear recoils for detector calibration and solid-state physics studies. This paper proposes a first-of-its-kind experiment to measure the twin products of neutron capture—the postcapture deexcitation gamma and postcapture nuclear recoil. Simulations show that with a 1 mCi californium neutron source, a positive measurement with existing detector technologies is possible in 26.1 gram-days of exposure.Keywords
All Related Versions
Funding Information
- U.S. Department of Energy (DE-SC0024275)
- National Science Foundation (2111090, 2411599)
This publication has 62 references indexed in Scilit:
- First Observation of a Nuclear Recoil Peak at $\mathcal {O}$(100eV) with Crab: A Potential New Calibration Standard for Cryogenic DetectorsJournal of Low Temperature Physics, 2024
- Accurate Calibration of Nuclear Recoils at the 100 eV Scale Using Neutron CaptureJournal of Low Temperature Physics, 2022
- Coherent elastic neutrino nucleus scatter response of semiconductor detectors to nuclear reactor antineutrinosNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021
- Single electron–hole pair sensitive silicon detector with surface event discriminationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2020
- The Use of Different Pulsed Electron Irradiation for the Formation of Radiation Defects in Silicon CrystalsJournal of Electronic Materials, 2018
- Background rejection of TEXONO experiment to explore the sub-keV energy region with HPGe detectorIndian Journal of Physics, 2017
- Precision measurement of radioactivity in gamma-rays spectrometry using two HPGe detectors (BEGe-6530 and GC0818-7600SL models) comparison techniques: Application to the soil measurementMethodsX, 2017
- Detection of Antineutrinos for Reactor MonitoringNuclear Engineering and Technology, 2016
- Resolution, efficiency and stability of HPGe detector operating in a magnetic field at various gamma-ray energiesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- Calorimetric ionization detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1990