Anthony Nicholas Villano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Anthony Nicholas Villano has a total of 667 co-authors. Here are the top co-authors by number of shared publications:
P. Cushman
17 shared publications- Enectali Figueroa-Feliciano
Northwestern University
16 shared publications - Tarek Saab
University of Florida
16 shared publications - David G. Cerdeno
Instituto de Física Teórica IFT-UAM/CSIC 28049 Madrid Spain
15 shared publications - Matt Pyle
University of California
15 shared publications N. Mirabolfathi
15 shared publications
Latest Publications
- Open Access
- 9 September 2026
- Published by Elsevier in Astroparticle Physics
- Vol. 184
Calibration and performance of germanium high voltage detectors for SuperCDMS SNOLAB
- 9 September 2026
- Published by Elsevier in Astroparticle Physics
- Vol. 184
Open AccessCalibration and performance of germanium high voltage detectors for SuperCDMS SNOLAB
- Open Access
- 22 April 2026
- Published by Office of Scientific and Technical Information (OSTI)
Extremely Low Energy Nuclear Recoil Calibrations for Dark Matter Direct Detection (Final Technical Report)
The final technical report for DE-SC0021364
- 22 April 2026
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessExtremely Low Energy Nuclear Recoil Calibrations for Dark Matter Direct Detection (Final Technical Report)
The final technical report for DE-SC0021364
- Open Access
- 2 February 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (3)
Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV detector
We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of 6.1 g · days of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as 1 MeV / c 2 , as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses > 1.2 eV / c 2 probed via absorption processes.
- 2 February 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (3)
Open AccessSearch for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV detector
We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of 6.1 g · days of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as 1 MeV / c 2 , as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses > 1.2 eV / c 2 probed via absorption processes.
- 21 November 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (9)
Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps
- 21 November 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (9)
Low-energy calibration of SuperCDMS HVeV cryogenic silicon calorimeters using Compton steps
- Open Access
- 3 October 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (7)
Novel coincidence detection technique for precision measurement of neutron capture-induced nuclear recoils
The lattice dynamics following particle interactions remain not fully understood, and effects from nuclear-recoil interactions in conventional solid-state detectors—such as defect formation—can hinder accurate event-energy interpretation. Neutron capture ( n , γ ) can produce detectable, precise-energy nuclear recoils for detector calibration and solid-state physics studies. This paper proposes a first-of-its-kind experiment to measure the twin products of neutron capture—the postcapture deexcitation gamma and postcapture nuclear recoil. Simulations show that with a 1 mCi californium neutron source, a positive measurement with existing detector technologies is possible in 26.1 gram-days of exposure.
- 3 October 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 112 (7)
Open AccessNovel coincidence detection technique for precision measurement of neutron capture-induced nuclear recoils
The lattice dynamics following particle interactions remain not fully understood, and effects from nuclear-recoil interactions in conventional solid-state detectors—such as defect formation—can hinder accurate event-energy interpretation. Neutron capture ( n , γ ) can produce detectable, precise-energy nuclear recoils for detector calibration and solid-state physics studies. This paper proposes a first-of-its-kind experiment to measure the twin products of neutron capture—the postcapture deexcitation gamma and postcapture nuclear recoil. Simulations show that with a 1 mCi californium neutron source, a positive measurement with existing detector technologies is possible in 26.1 gram-days of exposure.
- 7 June 2024
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 216 (1-2) , 1-7
Liquid $^3$He Detectors for Neutrons- 7 June 2024
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 216 (1-2) , 1-7
Liquid $^3$He Detectors for Neutrons- Open Access
Response of a Liquid $^3$He Neutron Detector
The $^3$He(n,p) process is excellent for neutron detection between thermal and $\sim$4\,MeV because of the high cross section and near-complete energy transfer from the neutron to the proton. This process is typically used in gaseous forms with ionization readout detectors. Here we study the response of a liquid $^3$He neutron detector with a scintillation readout. We anticipate an efficiency boost of around a factor of 64 compared to 10\,atm gaseous detectors, given similar detector volumes.
Open AccessResponse of a Liquid $^3$He Neutron Detector
The $^3$He(n,p) process is excellent for neutron detection between thermal and $\sim$4\,MeV because of the high cross section and near-complete energy transfer from the neutron to the proton. This process is typically used in gaseous forms with ionization readout detectors. Here we study the response of a liquid $^3$He neutron detector with a scintillation readout. We anticipate an efficiency boost of around a factor of 64 compared to 10\,atm gaseous detectors, given similar detector volumes.
- Open Access
- 8 August 2023
- Published by The Open Journal in Journal of Open Source Education
- Vol. 6 (66) , 184
The Data Behind Dark Matter: Exploring Galactic Rotation
- 8 August 2023
- Published by The Open Journal in Journal of Open Source Education
- Vol. 6 (66) , 184
Open AccessThe Data Behind Dark Matter: Exploring Galactic Rotation
- Open Access
Neutron capture-induced nuclear recoils as background for CE$ν$NS~measurements at reactors
Nuclear reactors represent a promising neutrino source for CE$\nu$NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CE$\nu$NS signal for recoils $\lesssim$\,100\,eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. In this work we quantify the impact of this background and show that, for a measurement 10\,m from a 1\,MW reactor, the effective thermal neutron flux should be kept below $\sim$~7$\times$~10$^{-4}$\,n/cm$^2$s so that the CE$\nu$NS events can be measured at least at a 5$\sigma$ level with germanium detectors in 100~kg\,yr exposure time. This flux corresponds to 60\% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CE$\nu$NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.Open AccessNeutron capture-induced nuclear recoils as background for CE$ν$NS~measurements at reactors
Nuclear reactors represent a promising neutrino source for CE$\nu$NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CE$\nu$NS signal for recoils $\lesssim$\,100\,eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. In this work we quantify the impact of this background and show that, for a measurement 10\,m from a 1\,MW reactor, the effective thermal neutron flux should be kept below $\sim$~7$\times$~10$^{-4}$\,n/cm$^2$s so that the CE$\nu$NS events can be measured at least at a 5$\sigma$ level with germanium detectors in 100~kg\,yr exposure time. This flux corresponds to 60\% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CE$\nu$NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.