Automated estimation of individualized organ-specific dose and noise from clinical CT scans
- 29 January 2025
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (3) , 035014
Abstract
Objective. Radiation dose and diagnostic image quality are opposing constraints in x-ray computed tomography (CT). Conventional methods do not fully account for organ-level radiation dose and noise when considering radiation risk and clinical task. In this work, we develop a pipeline to generate individualized organ-specific dose and noise at desired dose levels from clinical CT scans. Approach. To estimate organ-specific dose and noise, we compute dose maps, noise maps at desired dose levels and organ segmentations. In our pipeline, dose maps are generated using Monte Carlo simulation. The noise map is obtained by scaling the inserted noise in synthetic low-dose emulation in order to avoid anatomical structures, where the scaling coefficients are empirically calibrated. Organ segmentations are generated by a deep learning-based method (TotalSegmentator). The proposed noise model is evaluated on a clinical dataset of 12 CT scans, a phantom dataset of 3 uniform phantom scans, and a cross-site dataset of 26 scans. The accuracy of deep learning-based segmentations for organ-level dose and noise estimates was tested using a dataset of 41 cases with expert segmentations of six organs: lungs, liver, kidneys, bladder, spleen, and pancreas. Main results. The empirical noise model performs well, with an average RMSE approximately 1.5 HU and an average relative RMSE approximately 5% across different dose levels. The segmentation from TotalSegmentator yielded a mean Dice score of 0.8597 across the six organs (max = 0.9315 in liver, min = 0.6855 in pancreas). The resulting error in organ-level dose and noise estimation was less than 2% for most organs. Significance. The proposed pipeline can output individualized organ-specific dose and noise estimates accurately for personalized protocol evaluation and optimization. It is fully automated and can be scalable to large clinical datasets. This pipeline can be used to optimize image quality for specific organs and thus clinical tasks, without adversely affecting overall radiation dose.Keywords
Funding Information
- GE Healthcare
This publication has 39 references indexed in Scilit:
- A machine learning-based pipeline for multi-organ/tissue patient-specific radiation dosimetry in CTEuropean Radiology, 2024
- Rapid estimation of patient‐specific organ doses using a deep learning networkMedical Physics, 2023
- Patient‐specific radiation risk‐based tube current modulation for diagnostic CTMedical Physics, 2022
- Technical note: Evaluation of a V‐Net autosegmentation algorithm for pediatric CT scans: Performance, generalizability, and application to patient‐specific CT dosimetryMedical Physics, 2022
- Real‐time estimation of patient‐specific dose distributions for medical CT using the deep dose estimationMedical Physics, 2022
- Reconstruction of three‐dimensional tomographic patient models for radiation dose modulation in CT from two scout views using deep learningMedical Physics, 2022
- Validation of a deterministic linear Boltzmann transport equation solver for rapid CT dose computation using physical dose measurements in pediatric phantomsMedical Physics, 2021
- A method of rapid quantification of patient‐specific organ doses for CT using deep‐learning‐based multi‐organ segmentation and GPU‐accelerated Monte Carlo dose computingMedical Physics, 2020
- A fast, linear Boltzmann transport equation solver for computed tomography dose calculation (Acuros CTD)Medical Physics, 2018
- Pixel-wise estimation of noise statistics on iterative CT reconstruction from a single scanMedical Physics, 2017