GSGrant M Stevens

Grant M Stevens

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Grant M Stevens has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Scout-Dose-TCM: direct and prospective scout-based estimation of personalized organ and effective doses from tube current modulated CT exams

    by Maria Jose Medrano, Sen Wang, Liyan Sun, Abdullah-Al-Zubaer Imran, Jennie Cao, Grant M Stevens, Justin R Tse, Adam S Wang

    Objective. This study proposes Scout-Dose-TCM for direct, prospective estimation of organ-level and effective doses under tube current modulation (TCM) and compares its performance with two established methods. Approach. Contrast-enhanced chest-abdomen-pelvis CT exams from 130 adults (120 kVp, TCM) were analyzed. Reference organ doses for six organs (lungs, kidneys, liver, pancreas, bladder, spleen) were calculated using Monte Carlo (MC)-GPU and TotalSegmentator. These data trained Scout-Dose-TCM, a deep-learning model that predicts organ-level doses corresponding to discrete cosine transform (DCT) basis functions, enabling real-time estimation for any TCM profile. The model includes a feature-learning module that extracts contextual information from lateral and frontal scouts and scan range, and a dose-learning module that outputs DCT-based dose estimates. The loss function incorporated the DCT formulation, ensuring accurate predictions across variable TCM patterns. For comparison, dose estimation was performed following AAPM Task Group 204 (Global CTDI vol ) and its TCM-adapted and organ-specific version (Organ CTDI vol ). The three evaluated methods were extended to estimate effective dose and compared against the approach in AAPM Report 96, which applies a fixed dose-length product-to-effective-dose conversion factor. Five-fold cross-validation assessed generalizability via mean absolute percentage dose errors and R 2 correlations with MC benchmarks. Main Results. Mean organ-level absolute percentage errors were 13% (Global CTDI vol ), 9% (Organ CTDI vol ), and 7% (Scout-Dose-TCM). The largest discrepancies occurred for the bladder (15%, 13%, and 9%). Scout-Dose-TCM significantly reduced organ-level dose errors versus Global CTDI vol ( p < 1 × 10 −7 ) and improved predictions for liver, bladder, and pancreas versus Organ CTDI vol ( p ⩽ 0.005). It also achieved higher R 2 values and lower effective-dose error (3.01%) than Global (3.87%) and Organ (4.16%) CTDI vol , and the AAPM Task Group 96 method (31%). Significance. Scout-Dose-TCM outperformed Global CTDI vol and was comparable to or better than Organ CTDI vol for organ and effective dose estimation without requiring segmentations at inference, demonstrating its clinical potential for prospective dose estimation in CT.


  • Automated estimation of individualized organ-specific dose and noise from clinical CT scans

    by Sen Wang, Maria Jose Medrano, Abdullah Al Zubaer Imran, Wonkyeong Lee, Jennie Jiayi Cao, Grant M Stevens, Justin Ruey Tse, Adam S Wang

    Objective. Radiation dose and diagnostic image quality are opposing constraints in x-ray computed tomography (CT). Conventional methods do not fully account for organ-level radiation dose and noise when considering radiation risk and clinical task. In this work, we develop a pipeline to generate individualized organ-specific dose and noise at desired dose levels from clinical CT scans. Approach. To estimate organ-specific dose and noise, we compute dose maps, noise maps at desired dose levels and organ segmentations. In our pipeline, dose maps are generated using Monte Carlo simulation. The noise map is obtained by scaling the inserted noise in synthetic low-dose emulation in order to avoid anatomical structures, where the scaling coefficients are empirically calibrated. Organ segmentations are generated by a deep learning-based method (TotalSegmentator). The proposed noise model is evaluated on a clinical dataset of 12 CT scans, a phantom dataset of 3 uniform phantom scans, and a cross-site dataset of 26 scans. The accuracy of deep learning-based segmentations for organ-level dose and noise estimates was tested using a dataset of 41 cases with expert segmentations of six organs: lungs, liver, kidneys, bladder, spleen, and pancreas. Main results. The empirical noise model performs well, with an average RMSE approximately 1.5 HU and an average relative RMSE approximately 5% across different dose levels. The segmentation from TotalSegmentator yielded a mean Dice score of 0.8597 across the six organs (max = 0.9315 in liver, min = 0.6855 in pancreas). The resulting error in organ-level dose and noise estimation was less than 2% for most organs. Significance. The proposed pipeline can output individualized organ-specific dose and noise estimates accurately for personalized protocol evaluation and optimization. It is fully automated and can be scalable to large clinical datasets. This pipeline can be used to optimize image quality for specific organs and thus clinical tasks, without adversely affecting overall radiation dose.