Application Specific Integrated Circuits for High Resolution X and Gamma Ray Semiconductor Detectors
Author:
Open Access
- 1 January 2022
- book chapter
- Published by Springer Nature
- p. 31-42
Abstract
The increasing demand for performance improvements in radiation detectors, driven by cutting-edge research in nuclear physics, astrophysics and medical imaging, is causing not only a proliferation in the variety of the radiation sensors, but also a growing necessity of tailored solutions for the front-end readout electronics. Within this work, novel solutions for application specific integrated circuits (ASICs) adopted in high-resolution X and $$\upgamma $$ ray spectroscopy applications are studied. In the first part of this work, an ultra-low noise charge sensitive amplifier (CSA) is presented, with specific focus on sub-microsecond filtering, addressing the growing interest in high-luminosity experiments. The CSA demonstrated excellent results with Silicon Drift Detectors (SDDs), and with room temperature Cadmium-Telluride (CdTe) detectors, recording a state-of-the-art noise performance. The integration of the CSA within two full-custom radiation detection instruments realized for the ELETTRA (Trieste, Italy) and SESAME (Allan, Jordan) synchrotrons is also presented. In the second part of this work, an ASIC constellation designed for X-Gamma imaging spectrometer (XGIS) onboard of the THESEUS space mission is described. The presented readout ASIC has a highly customized distributed architecture, and integrates a complete on-chip signal filtering, acquisition and digitization with an ultra-low power consumption.
Keywords
This publication has 11 references indexed in Scilit:
- SIRIO: A High-Speed CMOS Charge-Sensitive Amplifier for High-Energy-Resolution X-γ Ray Spectroscopy With Semiconductor DetectorsIEEE Transactions on Nuclear Science, 2021
- The X/Gamma-ray Imaging Spectrometer (XGIS) on-board THESEUS: design, main characteristics, and concept of operation2020
- LYRA: A Multi-Chip ASIC Designed for HERMES X and Gamma Ray Detector2019
- The XAFS fluorescence detector system based on 64 silicon drift detectors for the SESAME synchrotron light sourceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2019
- A CdTe pixel detector–CMOS preamplifier for room temperature high sensitivity and energy resolution X and ray spectroscopic imagingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2018
- A new large solid angle multi-element silicon drift detector system for low energy X-ray fluorescence spectroscopyJournal of Instrumentation, 2018
- Noise Minimization of MOSFET Input Charge Amplifiers Based on $\Delta\mu$ and $\Delta{\rm N}$$1/f$ ModelsIEEE Transactions on Nuclear Science, 2009
- CMOS preamplifier for low-capacitance detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997
- Semiconductor drift chamber — An application of a novel charge transport schemeNuclear Instruments and Methods in Physics Research, 1984
- Minimum noise pre-amplifier for fast ionization chambersIl Nuovo Cimento (1869-1876), 1956