Heart-centered positioning and tailored beam-shaping filtration for reduced radiation dose in coronary artery calcium imaging: a MESA study
Preprint
Abstract
Purpose Cardiac CT has a clear clinical role in the evaluation of coronary artery disease and assessment of coronary artery calcium (CAC) but the use of ionizing radiation limits clinical use. Beam shaping “bow-tie” filters determine the radiation dose and the effective scan field-of-view diameter (SFOV) by delivering higher X-ray fluence to a region centered at the isocenter. A method for positioning the heart near the isocenter could enable reduced SFOV imaging and reduce dose in cardiac scans. However, a predictive approach to center the heart, the extent to which heart centering can reduce the SFOV, and the associated dose reductions have not been assessed. The purpose of this study is to build a heart-centered patient positioning model, to test whether it reduces the SFOV required for accurate CAC scoring, and to quantify the associated reduction in radiation dose. Methods The location of 38,184 calcium lesions (3,151 studies) in the Multi-Ethnic Study of Atherosclerosis (MESA) were utilized to build a predictive heart-centered positioning model and compare the impact of SFOV on CAC scoring accuracy in heart-centered and conventional body-centered scanning. Then, the positioning model was applied retrospectively to an independent, contemporary cohort of 118 individuals (81 with CAC>0) at our institution to validate the model’s ability to maintain CAC accuracy while reducing the SFOV. In these patients, the reduction in dose associated with a reduced SFOV beam-shaping filter was quantified. Results Heart centering reduced the SFOV diameter 25.7% relative to body centering while maintaining high CAC scoring accuracy (0.82% risk reclassification rate). In our validation cohort, imaging at this reduced SFOV with heart-centered positioning and tailored beam-shaping filtration led to a 26.9% median dose reduction (25-75th percentile: 21.6 to 29.8%) without any calcium risk reclassification. Conclusions Heart-centered patient positioning enables a significant radiation dose reduction while maintaining CAC accuracy.Keywords
This publication has 33 references indexed in Scilit:
- Calcium Density of Coronary Artery Plaque and Risk of Incident Cardiovascular EventsJAMA, 2014
- The feasibility of a piecewise‐linear dynamic bowtie filterMedical Physics, 2013
- Comparison of Novel Risk Markers for Improvement in Cardiovascular Risk Assessment in Intermediate-Risk IndividualsJAMA, 2012
- The dappled nature of causes of psychiatric illness: replacing the organic–functional/hardware–software dichotomy with empirically based pluralismMolecular Psychiatry, 2012
- Fluence field optimization for noise and dose objectives in CTMedical Physics, 2011
- Strategies for Reducing Radiation Dose in CTRadiologic Clinics of North America, 2009
- Automatic Patient Centering for MDCT: Effect on Radiation DoseAmerican Journal of Roentgenology, 2007
- User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliabilityNeuroImage, 2006
- Multi-Ethnic Study of Atherosclerosis: Objectives and DesignAmerican Journal of Epidemiology, 2002
- Generation of photon energy deposition kernels using the EGS Monte Carlo codePhysics in Medicine & Biology, 1988