Brendan Colvert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Brendan Colvert has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Eva Kanso
Department of Aerospace and Mechanical Engineering, University of Southern California, Los Angeles, California 90089, USA
5 shared publications - Francisco Contijoch
Shu Chien-Gene Lay Department of Bioengineering, University of California San Diego, La Jolla, USA
4 shared publications - Amanda Craine
Department of Bioengineering, UC San Diego , 9500 Gilman Drive, MC0412, La Jolla, CA 92037
2 shared publications - Adhithi Raghavan
From the Departments of Computer Science Engineering (K.G., N.S.), Bioengineering (D.M.V., A.R.S., B.C., A.C., A.R., F.J.C.), and Radiology (F.J.C.), University of California, San Diego, 9500 Gilman Dr, MC 0412, La Jolla, CA 92093; and Department of Internal Medicine, Scripps Mercy Hospital, San Diego, Calif (D.M.V.).
1 shared publication Amanda Craine
Department of Bioengineering, University of California San Diego, La Jolla, CA
1 shared publicationAnderson R. Scott
From the Departments of Computer Science Engineering (K.G., N.S.), Bioengineering (D.M.V., A.R.S., B.C., A.C., A.R., F.J.C.), and Radiology (F.J.C.), University of California, San Diego, 9500 Gilman Dr, MC 0412, La Jolla, CA 92093; and Department of Internal Medicine, Scripps Mercy Hospital, San Diego, Calif (D.M.V.).
1 shared publication
Latest Publications
- Open Access
- 16 January 2023
- Published by Wiley in Medical Physics
- Vol. 50 (3) , 1349-1366
DiFiR‐CT: Distance field representation to resolve motion artifacts in computed tomography
Background: Motion during data acquisition leads to artifacts in computed tomography (CT) reconstructions. In cases such as cardiac imaging, not only is motion unavoidable, but evaluating the motion of the object is of clinical interest. Reducing motion artifacts has typically been achieved by developing systems with faster gantry rotation or via algorithms which measure and/or estimate the displacement. However, these approaches have had limited success due to both physical constraints as well as the challenge of estimating non‐rigid, temporally varying, and patient‐specific motion fields.Purpose: To develop a novel reconstruction method which generates time‐resolved, artifact‐free images without estimation or explicit modeling of the motion.Methods: We describe an analysis‐by‐synthesis approach which progressively regresses a solution consistent with the acquired sinogram. In our method, we focus on the movement of object boundaries. Not only are the boundaries the source of image artifacts, but object boundaries can simultaneously be used to represent both the object as well as its motion over time without the need for an explicit motion model. We represent the object boundaries via a signed distance function (SDF) which can be efficiently modeled using neural networks. As a result, optimization can be performed under spatial and temporal smoothness constraints without the need for explicit motion estimation.Results: We illustrate the utility of DiFiR‐CT in three imaging scenarios with increasing motion complexity: translation of a small circle, heart‐like change in an ellipse's diameter, and a complex topological deformation. Compared to filtered backprojection, DiFiR‐CT provides high quality image reconstruction for all three motions without hyperparameter tuning or change to the architecture. We also evaluate DiFiR‐CT's robustness to noise in the acquired sinogram and found its reconstruction to be accurate across a wide range of noise levels. Lastly, we demonstrate how the approach could be used for multi‐intensity scenes and illustrate the importance of the initial segmentation providing a realistic initialization. Code and supplemental movies are available athttps://kunalmgupta.github.io/projects/DiFiR‐CT.html.Conclusions: Projection data can be used to accurately estimate a temporally‐evolving scene without the need for explicit motion estimation using a neural implicit representation and analysis‐by‐synthesis approach.
- 16 January 2023
- Published by Wiley in Medical Physics
- Vol. 50 (3) , 1349-1366
Open AccessDiFiR‐CT: Distance field representation to resolve motion artifacts in computed tomography
Background: Motion during data acquisition leads to artifacts in computed tomography (CT) reconstructions. In cases such as cardiac imaging, not only is motion unavoidable, but evaluating the motion of the object is of clinical interest. Reducing motion artifacts has typically been achieved by developing systems with faster gantry rotation or via algorithms which measure and/or estimate the displacement. However, these approaches have had limited success due to both physical constraints as well as the challenge of estimating non‐rigid, temporally varying, and patient‐specific motion fields.Purpose: To develop a novel reconstruction method which generates time‐resolved, artifact‐free images without estimation or explicit modeling of the motion.Methods: We describe an analysis‐by‐synthesis approach which progressively regresses a solution consistent with the acquired sinogram. In our method, we focus on the movement of object boundaries. Not only are the boundaries the source of image artifacts, but object boundaries can simultaneously be used to represent both the object as well as its motion over time without the need for an explicit motion model. We represent the object boundaries via a signed distance function (SDF) which can be efficiently modeled using neural networks. As a result, optimization can be performed under spatial and temporal smoothness constraints without the need for explicit motion estimation.Results: We illustrate the utility of DiFiR‐CT in three imaging scenarios with increasing motion complexity: translation of a small circle, heart‐like change in an ellipse's diameter, and a complex topological deformation. Compared to filtered backprojection, DiFiR‐CT provides high quality image reconstruction for all three motions without hyperparameter tuning or change to the architecture. We also evaluate DiFiR‐CT's robustness to noise in the acquired sinogram and found its reconstruction to be accurate across a wide range of noise levels. Lastly, we demonstrate how the approach could be used for multi‐intensity scenes and illustrate the importance of the initial segmentation providing a realistic initialization. Code and supplemental movies are available athttps://kunalmgupta.github.io/projects/DiFiR‐CT.html.Conclusions: Projection data can be used to accurately estimate a temporally‐evolving scene without the need for explicit motion estimation using a neural implicit representation and analysis‐by‐synthesis approach.
- 1 November 2021
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 3 (6)
Octree Representation Improves Data Fidelity of Cardiac CT Images and Convolutional Neural Network Semantic Segmentation of Left Atrial and Ventricular Chambers
Octrees can reduce the memory footprint of three-dimensional imaging volumes with minimal loss of image quality through a user-controlled intensity tolerance parameter that enables convolutional ne... Purpose To assess whether octree representation and octree-based convolutional neural networks (CNNs) improve segmentation accuracy of three-dimensional images. Materials and Methods Cardiac CT ang...
- 1 November 2021
- Published by Radiological Society of North America (RSNA) in Radiology: Artificial Intelligence
- Vol. 3 (6)
Octree Representation Improves Data Fidelity of Cardiac CT Images and Convolutional Neural Network Semantic Segmentation of Left Atrial and Ventricular Chambers
Octrees can reduce the memory footprint of three-dimensional imaging volumes with minimal loss of image quality through a user-controlled intensity tolerance parameter that enables convolutional ne... Purpose To assess whether octree representation and octree-based convolutional neural networks (CNNs) improve segmentation accuracy of three-dimensional images. Materials and Methods Cardiac CT ang...
- Open Access
Heart-centered positioning and tailored beam-shaping filtration for reduced radiation dose in coronary artery calcium imaging: a MESA study
Purpose Cardiac CT has a clear clinical role in the evaluation of coronary artery disease and assessment of coronary artery calcium (CAC) but the use of ionizing radiation limits clinical use. Beam shaping “bow-tie” filters determine the radiation dose and the effective scan field-of-view diameter (SFOV) by delivering higher X-ray fluence to a region centered at the isocenter. A method for positioning the heart near the isocenter could enable reduced SFOV imaging and reduce dose in cardiac scans. However, a predictive approach to center the heart, the extent to which heart centering can reduce the SFOV, and the associated dose reductions have not been assessed. The purpose of this study is to build a heart-centered patient positioning model, to test whether it reduces the SFOV required for accurate CAC scoring, and to quantify the associated reduction in radiation dose. Methods The location of 38,184 calcium lesions (3,151 studies) in the Multi-Ethnic Study of Atherosclerosis (MESA) were utilized to build a predictive heart-centered positioning model and compare the impact of SFOV on CAC scoring accuracy in heart-centered and conventional body-centered scanning. Then, the positioning model was applied retrospectively to an independent, contemporary cohort of 118 individuals (81 with CAC>0) at our institution to validate the model’s ability to maintain CAC accuracy while reducing the SFOV. In these patients, the reduction in dose associated with a reduced SFOV beam-shaping filter was quantified. Results Heart centering reduced the SFOV diameter 25.7% relative to body centering while maintaining high CAC scoring accuracy (0.82% risk reclassification rate). In our validation cohort, imaging at this reduced SFOV with heart-centered positioning and tailored beam-shaping filtration led to a 26.9% median dose reduction (25-75th percentile: 21.6 to 29.8%) without any calcium risk reclassification. Conclusions Heart-centered patient positioning enables a significant radiation dose reduction while maintaining CAC accuracy.
Open AccessHeart-centered positioning and tailored beam-shaping filtration for reduced radiation dose in coronary artery calcium imaging: a MESA study
Purpose Cardiac CT has a clear clinical role in the evaluation of coronary artery disease and assessment of coronary artery calcium (CAC) but the use of ionizing radiation limits clinical use. Beam shaping “bow-tie” filters determine the radiation dose and the effective scan field-of-view diameter (SFOV) by delivering higher X-ray fluence to a region centered at the isocenter. A method for positioning the heart near the isocenter could enable reduced SFOV imaging and reduce dose in cardiac scans. However, a predictive approach to center the heart, the extent to which heart centering can reduce the SFOV, and the associated dose reductions have not been assessed. The purpose of this study is to build a heart-centered patient positioning model, to test whether it reduces the SFOV required for accurate CAC scoring, and to quantify the associated reduction in radiation dose. Methods The location of 38,184 calcium lesions (3,151 studies) in the Multi-Ethnic Study of Atherosclerosis (MESA) were utilized to build a predictive heart-centered positioning model and compare the impact of SFOV on CAC scoring accuracy in heart-centered and conventional body-centered scanning. Then, the positioning model was applied retrospectively to an independent, contemporary cohort of 118 individuals (81 with CAC>0) at our institution to validate the model’s ability to maintain CAC accuracy while reducing the SFOV. In these patients, the reduction in dose associated with a reduced SFOV beam-shaping filter was quantified. Results Heart centering reduced the SFOV diameter 25.7% relative to body centering while maintaining high CAC scoring accuracy (0.82% risk reclassification rate). In our validation cohort, imaging at this reduced SFOV with heart-centered positioning and tailored beam-shaping filtration led to a 26.9% median dose reduction (25-75th percentile: 21.6 to 29.8%) without any calcium risk reclassification. Conclusions Heart-centered patient positioning enables a significant radiation dose reduction while maintaining CAC accuracy.
- Open Access
- 1 July 2020
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 14 (3) , S70-S71
Cardiacquire Beam-shaping Filter Enables Significant Radiation Dose Reduction: Patient- And Organ-specific Results
- 1 July 2020
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 14 (3) , S70-S71
Open AccessCardiacquire Beam-shaping Filter Enables Significant Radiation Dose Reduction: Patient- And Organ-specific Results
- 27 November 2018
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 14 (1) , 016009
Training bioinspired sensors to classify flows
We consider the inverse problem of classifying flow patterns from local sensory measurements. This problem is inspired by the ability of various aquatic organisms to respond to ambient flow signals, and is relevant for translating these abilities to underwater robotic vehicles. In Colvert, Alsalman and Kanso, B&B (2018), we trained neural networks to classify vortical flows by relying on a single flow sensor that measures a 'time history' of the local vorticity. Here, we systematically investigate the effects of distinct types of sensors on the accuracy of flow classification. We consider four types of sensors-vorticity, flow velocities parallel and transverse to the direction of flow propagation, and flow speed-and show that the networks trained using transverse velocity outperform other networks, even when subjected to aggressive data corruption. We then train the network to classify flow patterns instantaneously, using a spatially-distributed array of sensors and a single 'one time' sensory measurement. The network, based on a handful of spatially-distributed sensors, exhibits remarkable accuracy in flow classification. These results lay the groundwork for developing learning algorithms for the dynamic deployment of sensory arrays in unsteady flows.
- 27 November 2018
- Published by IOP Publishing in Bioinspiration & Biomimetics
- Vol. 14 (1) , 016009
Training bioinspired sensors to classify flows
We consider the inverse problem of classifying flow patterns from local sensory measurements. This problem is inspired by the ability of various aquatic organisms to respond to ambient flow signals, and is relevant for translating these abilities to underwater robotic vehicles. In Colvert, Alsalman and Kanso, B&B (2018), we trained neural networks to classify vortical flows by relying on a single flow sensor that measures a 'time history' of the local vorticity. Here, we systematically investigate the effects of distinct types of sensors on the accuracy of flow classification. We consider four types of sensors-vorticity, flow velocities parallel and transverse to the direction of flow propagation, and flow speed-and show that the networks trained using transverse velocity outperform other networks, even when subjected to aggressive data corruption. We then train the network to classify flow patterns instantaneously, using a spatially-distributed array of sensors and a single 'one time' sensory measurement. The network, based on a handful of spatially-distributed sensors, exhibits remarkable accuracy in flow classification. These results lay the groundwork for developing learning algorithms for the dynamic deployment of sensory arrays in unsteady flows.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2756-2761
How can a source be located by responding to local information in its hydrodynamic trail?
In this work we propose a model system in which a bioinspired sensory platform responds to cues in the hydrodynamic trail of a source. We model the hydrodynamic trail as a band-limited traveling wave and propose a localized sensing strategy for decoding the information contained therein. Then, we propose a control law whereby the sensory platform reorients in response to local cues contained within the sensory information. We couple this control law with a behavioral kinematic model to test its effectiveness. Finally, we demonstrate the abilities of this sensing strategy and behavioral model in a canonical source-seeking problem, the wake of a pitching foil.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2756-2761
How can a source be located by responding to local information in its hydrodynamic trail?
In this work we propose a model system in which a bioinspired sensory platform responds to cues in the hydrodynamic trail of a source. We model the hydrodynamic trail as a band-limited traveling wave and propose a localized sensing strategy for decoding the information contained therein. Then, we propose a control law whereby the sensory platform reorients in response to local cues contained within the sensory information. We couple this control law with a behavioral kinematic model to test its effectiveness. Finally, we demonstrate the abilities of this sensing strategy and behavioral model in a canonical source-seeking problem, the wake of a pitching foil.
- 31 March 2017
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 818, 366-381
Local flow characterization using bioinspired sensory information
Most marine creatures exhibit remarkable flow sensing abilities. Their task of discerning hydrodynamic cues from local sensory information is particularly challenging because it relies on local and partial measurements to accurately characterize the ambient flow. This is in contrast to classical flow characterization methods, which invariably depend on the ability of an external observer to reconstruct the flow field globally and identify its topological structures. In this paper, we develop a mathematical framework in which a local sensory array is used to identify select flow features. Our approach consists of linearizing the flow field around the sensory array and providing a frame-independent parameterization of the velocity gradient tensor which reveals both the local flow ‘type’ and ‘intensity’. We show that a simple bioinspired sensory system that measures differences in flow velocities is capable of locally characterizing the flow type and intensity. We discuss the conditions under which such flow characterization is possible. Then, to demonstrate the effectiveness of this sensory system, we apply it in the canonical problem of a circular cylinder in uniform flow. We find excellent agreement between the sensed and actual flow properties. These findings will serve to direct future research on optimal sensory layouts and dynamic deployment of sensory arrays.
- 31 March 2017
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 818, 366-381
Local flow characterization using bioinspired sensory information
Most marine creatures exhibit remarkable flow sensing abilities. Their task of discerning hydrodynamic cues from local sensory information is particularly challenging because it relies on local and partial measurements to accurately characterize the ambient flow. This is in contrast to classical flow characterization methods, which invariably depend on the ability of an external observer to reconstruct the flow field globally and identify its topological structures. In this paper, we develop a mathematical framework in which a local sensory array is used to identify select flow features. Our approach consists of linearizing the flow field around the sensory array and providing a frame-independent parameterization of the velocity gradient tensor which reveals both the local flow ‘type’ and ‘intensity’. We show that a simple bioinspired sensory system that measures differences in flow velocities is capable of locally characterizing the flow type and intensity. We discuss the conditions under which such flow characterization is possible. Then, to demonstrate the effectiveness of this sensory system, we apply it in the canonical problem of a circular cylinder in uniform flow. We find excellent agreement between the sensed and actual flow properties. These findings will serve to direct future research on optimal sensory layouts and dynamic deployment of sensory arrays.
- 1 March 2017
- Published by Springer Nature in Journal of Nonlinear Science
- Vol. 27 (4) , 1183-1192
Bioinspired Sensory Systems for Shear Flow Detection
- 1 March 2017
- Published by Springer Nature in Journal of Nonlinear Science
- Vol. 27 (4) , 1183-1192
Bioinspired Sensory Systems for Shear Flow Detection
- 18 March 2016
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 793, 656-666
Fishlike rheotaxis
Fish rheotaxis, or alignment into flow currents, results from intertwined sensory, neural and actuation mechanisms, all coupled with hydrodynamics to produce a behaviour that is critical for upstream migration and position holding in oncoming flows. Among several sensory modalities, the lateral-line sensory system is thought to play a major role in the fish ability to sense minute water motions in their vicinity and, thus, in their rheotactic behaviour. Here, we propose a theoretical model consisting of a fishlike body equipped with lateral pressure sensors in oncoming uniform flows. We compute the optimal sensor locations that maximize the sensory output. Our results confirm recent experimental findings that correlate the layout of the lateral-line sensors with the distribution of hydrodynamic information at the fish surface. We then examine the behavioural response of the fishlike model as a function of its orientation and swimming speed relative to the background flow. Our working hypothesis is that fish respond to sensory information by adjusting their orientation according to the perceived difference in pressure. We find that, as in fish rheotaxis, the fishlike body responds by aligning into the oncoming flow. These findings may have significant implications on understanding the interplay between the sensory output and fish behaviour.
- 18 March 2016
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 793, 656-666
Fishlike rheotaxis
Fish rheotaxis, or alignment into flow currents, results from intertwined sensory, neural and actuation mechanisms, all coupled with hydrodynamics to produce a behaviour that is critical for upstream migration and position holding in oncoming flows. Among several sensory modalities, the lateral-line sensory system is thought to play a major role in the fish ability to sense minute water motions in their vicinity and, thus, in their rheotactic behaviour. Here, we propose a theoretical model consisting of a fishlike body equipped with lateral pressure sensors in oncoming uniform flows. We compute the optimal sensor locations that maximize the sensory output. Our results confirm recent experimental findings that correlate the layout of the lateral-line sensors with the distribution of hydrodynamic information at the fish surface. We then examine the behavioural response of the fishlike model as a function of its orientation and swimming speed relative to the background flow. Our working hypothesis is that fish respond to sensory information by adjusting their orientation according to the perceived difference in pressure. We find that, as in fish rheotaxis, the fishlike body responds by aligning into the oncoming flow. These findings may have significant implications on understanding the interplay between the sensory output and fish behaviour.