Abstract
Explicit model predictive direct speed control (EMP-DSC) for permanent magnet synchronous motors (PMSMs) can achieve excellent control performance with high dynamics and high precision. However, the universality of existing circular-constraint linearization and the flux-weakening region’s current-distribution strategy is limited, making it difficult to fully exploit the extreme operating capability of motors with different parameters. Therefore, this article fully combines the EMP constraint linearization principle and the motor’s flux-weakening mechanism, and proposes an EMP-DSC method based on “chord constraint” that is highly adapted to flux-weakening operation. The proposed method first obtains the extreme slopes of lines connecting the intersection points of the voltage and current limit circles with the center of the voltage-limit circle across the entire speed range in the $d$ – $q$ axis current plane. Then, a single, fixed arc on the voltage-limit circle that participates in the entire flux-weakening process is determined, and its corresponding chord is used as a boundary to construct the optimal voltage-constraint polytope and used as the flux-weakening trajectory to determine the current distribution. The proposed universal method enables full utilization of the extreme operating capabilities of motors with different parameters under the EMP-DSC framework, and its feasibility is validated by experimental results.
Funding Information
  • National Natural Science Foundation of China (52507073)
  • National Natural Science Foundation of China (KC25023)

This publication has 26 references indexed in Scilit: