He Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
He Cheng has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Dongsheng Yu
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
6 shared publications - Guoqiang Han
Department of electrical engineering, China University of Mining and Technology, Xuzhou, China
6 shared publications - Haoyue Tang
China University of Mining and Technology
4 shared publications - Wenju Yan
School of Electrical Engineering, China University of Mining and Technology, Xuzhou, China
4 shared publications Dali Shao
School of Electrical and Power Engineering, China University of Mining and Technology, Xuzhou, China
3 shared publications- Hao Chen
China University of Mining and Technology
3 shared publications
Latest Publications
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 15121-15136
Identification and Localization for Inter-Turn Short Circuit Fault of PMSMs Using α-β Plane Voltage and Current in FOC
With the increasing power and torque density of the permanent magnet synchronous motor (PMSM), the windings will experience higher electrical and thermal stresses, which may induce the inter-turn short circuit fault (ISCF). This paper proposes a diagnosis method for the ISCF of the PMSM using α-β plane variables in Field-Oriented Control (FOC). The mathematical model of the PMSM with ISCFs in the α-β plane is derived, and the usable fault features existing in the analytical expressions are analyzed. The second-order generalized integrator (SOGI) is utilized to construct the current residual that includes the short-circuit ratio and short-circuit current for identifying the ISCF. The polarity characteristic presents in the α-β plane voltage with different fault phases are explored. The fault factor for fault location is defined through the combination and logical operation of the characteristic variable. The processed fault factor is the DC quantity that is highly sensitive to the ISCF and is independent of motor parameters. The advantage of the proposed method is that the fault factor is derived from the analytical expression of the voltage and current inherently in the α-β plane, avoiding the iterative calculation, additional hardware, signal injection, and the establishment of specialized models for extracting fault characteristics. The experiment result demonstrates that the proposed method can identify and locate the ISCF, and has the robustness to sudden changes in operating conditions and parameter uncertainties.
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (9) , 15121-15136
Identification and Localization for Inter-Turn Short Circuit Fault of PMSMs Using α-β Plane Voltage and Current in FOC
With the increasing power and torque density of the permanent magnet synchronous motor (PMSM), the windings will experience higher electrical and thermal stresses, which may induce the inter-turn short circuit fault (ISCF). This paper proposes a diagnosis method for the ISCF of the PMSM using α-β plane variables in Field-Oriented Control (FOC). The mathematical model of the PMSM with ISCFs in the α-β plane is derived, and the usable fault features existing in the analytical expressions are analyzed. The second-order generalized integrator (SOGI) is utilized to construct the current residual that includes the short-circuit ratio and short-circuit current for identifying the ISCF. The polarity characteristic presents in the α-β plane voltage with different fault phases are explored. The fault factor for fault location is defined through the combination and logical operation of the characteristic variable. The processed fault factor is the DC quantity that is highly sensitive to the ISCF and is independent of motor parameters. The advantage of the proposed method is that the fault factor is derived from the analytical expression of the voltage and current inherently in the α-β plane, avoiding the iterative calculation, additional hardware, signal injection, and the establishment of specialized models for extracting fault characteristics. The experiment result demonstrates that the proposed method can identify and locate the ISCF, and has the robustness to sudden changes in operating conditions and parameter uncertainties.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
Low-Optimization-Dimensional Explicit Model Predictive Current Control for IPMSM Based on Hard Constraints
The torque control performance of interior permanent magnet synchronous motors is determined by the control effectiveness of both d- and q-axis currents. Explicit model predictive (EMP) control, with superior capability for multi-variable and multi-objective coordinated control, has become a high-quality solution for d– and q-axis current control. However, the multi-parametric quadratic programming problem formulated and solved in the existing EMP current control method is a high-dimensional optimization problem, and its offline solution yields a large number of critical regions, imposing high demands on microprocessor memory and computational power. Consequently, expensive rapid-control-prototype controllers with sufficient memory are often required for implementation. To this end, this paper proposes a low-optimization-dimensional EMP current control method, in which the dual-current tracking task conventionally implemented via quadratic penalty terms in the cost function is transformed into equality hard constraints by fully leveraging the powerful and flexible constraint-handling capability of EMP algorithms. The proposed method simplifies the original 4-dimensional space optimization problem into a 2-dimensional one, significantly reducing the solution complexity and microprocessor memory requirements, thereby enhancing the practicality and competitiveness of EMP current control in low-cost applications. The proposed method’s feasibility and superiority are validated through both simulations and hardware experiments.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. PP (4) , 1
Low-Optimization-Dimensional Explicit Model Predictive Current Control for IPMSM Based on Hard Constraints
The torque control performance of interior permanent magnet synchronous motors is determined by the control effectiveness of both d- and q-axis currents. Explicit model predictive (EMP) control, with superior capability for multi-variable and multi-objective coordinated control, has become a high-quality solution for d– and q-axis current control. However, the multi-parametric quadratic programming problem formulated and solved in the existing EMP current control method is a high-dimensional optimization problem, and its offline solution yields a large number of critical regions, imposing high demands on microprocessor memory and computational power. Consequently, expensive rapid-control-prototype controllers with sufficient memory are often required for implementation. To this end, this paper proposes a low-optimization-dimensional EMP current control method, in which the dual-current tracking task conventionally implemented via quadratic penalty terms in the cost function is transformed into equality hard constraints by fully leveraging the powerful and flexible constraint-handling capability of EMP algorithms. The proposed method simplifies the original 4-dimensional space optimization problem into a 2-dimensional one, significantly reducing the solution complexity and microprocessor memory requirements, thereby enhancing the practicality and competitiveness of EMP current control in low-cost applications. The proposed method’s feasibility and superiority are validated through both simulations and hardware experiments.
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 20 (1)
Fractional‐Order Repetitive Control‐Based Two‐Degree‐of‐Freedom ADR Current Control for PMSM Drives
The current loop of a permanent magnet synchronous motor is subject to multi‐source disturbances, including constant disturbances caused by parameter mismatches and periodic disturbances induced by permanent magnet flux harmonics and inverter nonlinear voltage errors. Both types of disturbances negatively impact system control performance. Existing two‐degree‐of‐freedom active disturbance rejection (2DOF‐ADR) current control methods introduce an integer‐order repetitive control (IRC) term into the extended state observer (ESO), forming a proportional‐integral integer‐order repetitive ESO capable of simultaneously suppressing both constant and periodic disturbances. However, the IRC employed in existing methods utilises an integer‐order delay element, resulting in a deviation of the selective gain centre from the target frequency of periodic disturbances, thereby reducing the disturbance rejection performance. Therefore, this paper proposes a fractional‐order repetitive control‐based 2DOF‐ADR current control method, in which the integer‐order delay element of the IRC in the existing PIIR‐ESO is replaced with a fractional‐order delay element. The proposed method employs fractional‐order delay elements to reduce the frequency‐matching deviation for periodic disturbances, thereby enhancing the suppression of periodic disturbances while maintaining the 2DOF tuning characteristic between reference tracking and disturbance rejection performance. The effectiveness of the proposed method is validated through experimental results.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 20 (1)
Open AccessFractional‐Order Repetitive Control‐Based Two‐Degree‐of‐Freedom ADR Current Control for PMSM Drives
The current loop of a permanent magnet synchronous motor is subject to multi‐source disturbances, including constant disturbances caused by parameter mismatches and periodic disturbances induced by permanent magnet flux harmonics and inverter nonlinear voltage errors. Both types of disturbances negatively impact system control performance. Existing two‐degree‐of‐freedom active disturbance rejection (2DOF‐ADR) current control methods introduce an integer‐order repetitive control (IRC) term into the extended state observer (ESO), forming a proportional‐integral integer‐order repetitive ESO capable of simultaneously suppressing both constant and periodic disturbances. However, the IRC employed in existing methods utilises an integer‐order delay element, resulting in a deviation of the selective gain centre from the target frequency of periodic disturbances, thereby reducing the disturbance rejection performance. Therefore, this paper proposes a fractional‐order repetitive control‐based 2DOF‐ADR current control method, in which the integer‐order delay element of the IRC in the existing PIIR‐ESO is replaced with a fractional‐order delay element. The proposed method employs fractional‐order delay elements to reduce the frequency‐matching deviation for periodic disturbances, thereby enhancing the suppression of periodic disturbances while maintaining the 2DOF tuning characteristic between reference tracking and disturbance rejection performance. The effectiveness of the proposed method is validated through experimental results.
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 2612-2627
Explicit Model Predictive Direct Speed Control Method for PMSMs Based on High-Adaptability Flux-Weakening Chord Constraint
Explicit model predictive direct speed control (EMP-DSC) for permanent magnet synchronous motors (PMSMs) can achieve excellent control performance with high dynamics and high precision. However, the universality of existing circular-constraint linearization and the flux-weakening region’s current-distribution strategy is limited, making it difficult to fully exploit the extreme operating capability of motors with different parameters. Therefore, this article fully combines the EMP constraint linearization principle and the motor’s flux-weakening mechanism, and proposes an EMP-DSC method based on “chord constraint” that is highly adapted to flux-weakening operation. The proposed method first obtains the extreme slopes of lines connecting the intersection points of the voltage and current limit circles with the center of the voltage-limit circle across the entire speed range in the $d$ – $q$ axis current plane. Then, a single, fixed arc on the voltage-limit circle that participates in the entire flux-weakening process is determined, and its corresponding chord is used as a boundary to construct the optimal voltage-constraint polytope and used as the flux-weakening trajectory to determine the current distribution. The proposed universal method enables full utilization of the extreme operating capabilities of motors with different parameters under the EMP-DSC framework, and its feasibility is validated by experimental results.
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 2612-2627
Explicit Model Predictive Direct Speed Control Method for PMSMs Based on High-Adaptability Flux-Weakening Chord Constraint
Explicit model predictive direct speed control (EMP-DSC) for permanent magnet synchronous motors (PMSMs) can achieve excellent control performance with high dynamics and high precision. However, the universality of existing circular-constraint linearization and the flux-weakening region’s current-distribution strategy is limited, making it difficult to fully exploit the extreme operating capability of motors with different parameters. Therefore, this article fully combines the EMP constraint linearization principle and the motor’s flux-weakening mechanism, and proposes an EMP-DSC method based on “chord constraint” that is highly adapted to flux-weakening operation. The proposed method first obtains the extreme slopes of lines connecting the intersection points of the voltage and current limit circles with the center of the voltage-limit circle across the entire speed range in the $d$ – $q$ axis current plane. Then, a single, fixed arc on the voltage-limit circle that participates in the entire flux-weakening process is determined, and its corresponding chord is used as a boundary to construct the optimal voltage-constraint polytope and used as the flux-weakening trajectory to determine the current distribution. The proposed universal method enables full utilization of the extreme operating capabilities of motors with different parameters under the EMP-DSC framework, and its feasibility is validated by experimental results.
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 2246-2258
Optimization Design of Three-Phase CLLC Resonant Converter Based on Planar Magnetic Integration
The three-phase CLLC resonant converter is widely used in on-board-charger application due to its low component stress, low-output ripple, and high-power density. However, the large number of switches, driver circuits, and magnetics in the converter can lead to low efficiency under light-load conditions. Although phase-shedding method can effectively improve light-load efficiency by shutting down one or two bridges when the load current decreases, implementing these strategies in resonant converters based on integrated magnetic cores is challenging due to the magnetic coupling between phases. To address this issue, this article proposes and optimizes a planar-integrated magnetic core structure that integrates all magnetic components, significantly enhancing power density. This structure effectively mitigates the coupling between phases, simplifying the implementation of the phase-shedding method and further reducing core losses with additional optimization. The effectiveness of the proposed optimized design is validated through experimental testing on a 2.5 kW three-phase CLLC resonant converter prototype based on SiC devices.
- 25 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 2246-2258
Optimization Design of Three-Phase CLLC Resonant Converter Based on Planar Magnetic Integration
The three-phase CLLC resonant converter is widely used in on-board-charger application due to its low component stress, low-output ripple, and high-power density. However, the large number of switches, driver circuits, and magnetics in the converter can lead to low efficiency under light-load conditions. Although phase-shedding method can effectively improve light-load efficiency by shutting down one or two bridges when the load current decreases, implementing these strategies in resonant converters based on integrated magnetic cores is challenging due to the magnetic coupling between phases. To address this issue, this article proposes and optimizes a planar-integrated magnetic core structure that integrates all magnetic components, significantly enhancing power density. This structure effectively mitigates the coupling between phases, simplifying the implementation of the phase-shedding method and further reducing core losses with additional optimization. The effectiveness of the proposed optimized design is validated through experimental testing on a 2.5 kW three-phase CLLC resonant converter prototype based on SiC devices.
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
Open-Circuit Fault Diagnosis Method for the Dual Three-Phase Permanent Magnet Synchronous Motor Drive in the Fault-Tolerant Mode
Dual three-phase permanent magnet synchronous motors (DT-PMSMs) can operate in the fault-tolerant mode with the minimum copper loss (MCL) or the maximum torque (MT) under the single-phase fault. However, the amplitude increases and uneven distribution of winding currents in the fault-tolerant mode will induce the drive open-circuit fault (OCF), including the OCF of a certain power switch and the open-phase fault (OPF) caused by the OCFs of two power switches in the same leg. This article proposes the diagnosis method for these two most common OCF types in the drive. Firstly, the principle of fault-tolerant operation and current distribution based on the vector space decomposition are analyzed. Secondly, the analytical expressions of the winding current and the harmonic plane current (x-y plane current) in two fault-tolerant modes with OPF and power switch OCF are derived, and it is found that the x-y plane current has more obvious fault characteristics than the winding current. Furthermore, considering the interference caused by noise and changes in operating conditions, the fault threshold is defined based on the variation interval of the normalized x-y plane current, and the polarity of x-y plane current is combined to identify and locate the fault. Finally, the experiment shows that the proposed method can effectively diagnose the drive OCF within one fundamental current cycle. In the face of sudden changes in speed and torque, including the load is increased from 0.35 times rated load to 0.62 times rated load while keeping the speed unchanged and the speed is increased from 0.3 times rated speed to 0.6 times rated speed while keeping the load unchanged, the fault factor remains stable and will not trigger misdiagnosis.
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-15
Open-Circuit Fault Diagnosis Method for the Dual Three-Phase Permanent Magnet Synchronous Motor Drive in the Fault-Tolerant Mode
Dual three-phase permanent magnet synchronous motors (DT-PMSMs) can operate in the fault-tolerant mode with the minimum copper loss (MCL) or the maximum torque (MT) under the single-phase fault. However, the amplitude increases and uneven distribution of winding currents in the fault-tolerant mode will induce the drive open-circuit fault (OCF), including the OCF of a certain power switch and the open-phase fault (OPF) caused by the OCFs of two power switches in the same leg. This article proposes the diagnosis method for these two most common OCF types in the drive. Firstly, the principle of fault-tolerant operation and current distribution based on the vector space decomposition are analyzed. Secondly, the analytical expressions of the winding current and the harmonic plane current (x-y plane current) in two fault-tolerant modes with OPF and power switch OCF are derived, and it is found that the x-y plane current has more obvious fault characteristics than the winding current. Furthermore, considering the interference caused by noise and changes in operating conditions, the fault threshold is defined based on the variation interval of the normalized x-y plane current, and the polarity of x-y plane current is combined to identify and locate the fault. Finally, the experiment shows that the proposed method can effectively diagnose the drive OCF within one fundamental current cycle. In the face of sudden changes in speed and torque, including the load is increased from 0.35 times rated load to 0.62 times rated load while keeping the speed unchanged and the speed is increased from 0.3 times rated speed to 0.6 times rated speed while keeping the load unchanged, the fault factor remains stable and will not trigger misdiagnosis.
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 12219-12230
Fault-Tolerant Control Under Open-Circuit Faults Based on Four-Leg Power Converter for Doubly Salient Reluctance Machine
In this article, the fault-tolerant control under open-circuit faults based on four-leg power converter for doubly salient reluctance machine (DSRM) is presented. First, the mathematical model of the DSRM is built, and the normal operation mode is analyzed. Then, three fault-tolerant control modes are proposed according to the locations of the open-circuit faulty switches. When the faulty switches belong to groups 1 or 2, the multiple current chopping control (CCC) modes are adopted, respectively. When the faulty switches belong to group 3, the sinusoidal current without dc-bias control mode is employed. To reduce the torque fluctuation when the DSRM is switched from normal mode to fault-tolerant mode, the torque and current relationships between different control modes are analyzed. Then, the overall control scheme and smooth switching control strategy for different fault-tolerant modes are proposed. Finally, a three-phase 12/10 DSRM experimental platform is built, and the experiments are carried out to verify the effectiveness of the proposed fault-tolerant control method.
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (12) , 12219-12230
Fault-Tolerant Control Under Open-Circuit Faults Based on Four-Leg Power Converter for Doubly Salient Reluctance Machine
In this article, the fault-tolerant control under open-circuit faults based on four-leg power converter for doubly salient reluctance machine (DSRM) is presented. First, the mathematical model of the DSRM is built, and the normal operation mode is analyzed. Then, three fault-tolerant control modes are proposed according to the locations of the open-circuit faulty switches. When the faulty switches belong to groups 1 or 2, the multiple current chopping control (CCC) modes are adopted, respectively. When the faulty switches belong to group 3, the sinusoidal current without dc-bias control mode is employed. To reduce the torque fluctuation when the DSRM is switched from normal mode to fault-tolerant mode, the torque and current relationships between different control modes are analyzed. Then, the overall control scheme and smooth switching control strategy for different fault-tolerant modes are proposed. Finally, a three-phase 12/10 DSRM experimental platform is built, and the experiments are carried out to verify the effectiveness of the proposed fault-tolerant control method.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (8) , 11206-11217
Strong-Robustness Sliding Mode Torque Observer With Frequency Adaptive Filter Integrated for PMSMs
Accurate estimation of load torque is critical for optimizing the control performance of permanent-magnet synchronous motor (PMSM) drives. This article first establishes a mathematical model of the PMSM using coordinate transformation theory. Then, a nonsingular terminal sliding mode load torque observer (NTSMLO) is developed to precisely estimate load torque during motor operation, taking advantage of the nonsingular terminal sliding mode to achieve rapid response times and minimize chattering effects. However, traditional low-pass filters have problems with phase distortion and low roll-off rates, which limits their adaptability in dealing with external disturbances and time-varying parameters. To improve observation accuracy and enhance robustness, a frequency adaptive observer is integrated into the NTSMLO, forming the adaptive NTSMLO. Finally, the effectiveness of the proposed observer is validated through numerical simulations and experimental tests. Experimental results demonstrate significant improvements in both speed and parameter robustness over traditional sliding mode observers.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (8) , 11206-11217
Strong-Robustness Sliding Mode Torque Observer With Frequency Adaptive Filter Integrated for PMSMs
Accurate estimation of load torque is critical for optimizing the control performance of permanent-magnet synchronous motor (PMSM) drives. This article first establishes a mathematical model of the PMSM using coordinate transformation theory. Then, a nonsingular terminal sliding mode load torque observer (NTSMLO) is developed to precisely estimate load torque during motor operation, taking advantage of the nonsingular terminal sliding mode to achieve rapid response times and minimize chattering effects. However, traditional low-pass filters have problems with phase distortion and low roll-off rates, which limits their adaptability in dealing with external disturbances and time-varying parameters. To improve observation accuracy and enhance robustness, a frequency adaptive observer is integrated into the NTSMLO, forming the adaptive NTSMLO. Finally, the effectiveness of the proposed observer is validated through numerical simulations and experimental tests. Experimental results demonstrate significant improvements in both speed and parameter robustness over traditional sliding mode observers.
- 4 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (2) , 5793-5808
Fault-Tolerant Control for the Asymmetric Six-Phase Permanent Magnet Synchronous Motor With Open-Phase Faults
This article proposes a fault-tolerant control strategy suitable for the asymmetric six-phase permanent magnet synchronous motor (AS-PMSM) to improve its fault-tolerant performance and capability. The performance of the AS-PMSM with different types of the open-phase fault (OPF) is analyzed, and the best and worst fault-tolerant modes are pointed out. In order to make the motor have optimal fault-tolerant performance and reduce control complexity, a new transformation matrix is proposed based on the principle of constant magnetomotive force. The proposed transformation matrix and control method make the dimension of the AS-PMSM reduce to two. Good current tracking effect is achieved by using traditional PI controllers, and there is no need to change the current reference and reconfigure the current controller. A topology structure and a definition and usage of the "pseudo-fault" leg are proposed for the worst fault-tolerant mode to improve the performance of the AS-PMSM significantly in this mode. Moreover, the redundancy of the topology can be fully exploited by using the "pseudo-fault" leg, enabling the AS-PMSM to operate in all types of three OPFs. Furthermore, the conversion criterion between different fault-tolerant modes is also proposed, so that the AS-PMSM can operate in multiple OPF modes with satisfied performance. The test platform is built to verify the proposed theoretical method.
- 4 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (2) , 5793-5808
Fault-Tolerant Control for the Asymmetric Six-Phase Permanent Magnet Synchronous Motor With Open-Phase Faults
This article proposes a fault-tolerant control strategy suitable for the asymmetric six-phase permanent magnet synchronous motor (AS-PMSM) to improve its fault-tolerant performance and capability. The performance of the AS-PMSM with different types of the open-phase fault (OPF) is analyzed, and the best and worst fault-tolerant modes are pointed out. In order to make the motor have optimal fault-tolerant performance and reduce control complexity, a new transformation matrix is proposed based on the principle of constant magnetomotive force. The proposed transformation matrix and control method make the dimension of the AS-PMSM reduce to two. Good current tracking effect is achieved by using traditional PI controllers, and there is no need to change the current reference and reconfigure the current controller. A topology structure and a definition and usage of the "pseudo-fault" leg are proposed for the worst fault-tolerant mode to improve the performance of the AS-PMSM significantly in this mode. Moreover, the redundancy of the topology can be fully exploited by using the "pseudo-fault" leg, enabling the AS-PMSM to operate in all types of three OPFs. Furthermore, the conversion criterion between different fault-tolerant modes is also proposed, so that the AS-PMSM can operate in multiple OPF modes with satisfied performance. The test platform is built to verify the proposed theoretical method.
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (4) , 2134-2145
Development and Optimization Design of a Novel Double Stator Doubly Salient Variable Flux Memory Motor
In this paper, a novel double stator doubly salient variable flux memory motor (DS-DSVFMM) is proposed. Firstly, the topology structure and operation principle of the DS-DSVFMM are introduced. The equivalent magnetic circuit model is established, and the principle of online flux regulation is analyzed. Then, based on the structural characteristics of the proposed motor, the optimization objectives and constraints are established for the multi-objective optimization design. The structural parameters with high sensitivity to the motor performance are selected, and the response surface models of the key parameters for average torque, torque ripple and iron loss are constructed. The NSGA-II algorithm is used for the multi-objective optimization design, and the Pareto solution set and optimal structural parameters are obtained. The electromagnetic performance of the motor before and after optimization are compared and analyzed. It shows that the average torque is increased and torque ripple is decreased effectively. Meanwhile, the good flux regulation performance of the DS-DSVFMM is demonstrated, which verifies the effectiveness of the proposed motor topology and optimization method. Finally, the DS-DSVFMM prototype is fabricated and verified by no-load and load experiments.
- 3 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (4) , 2134-2145
Development and Optimization Design of a Novel Double Stator Doubly Salient Variable Flux Memory Motor
In this paper, a novel double stator doubly salient variable flux memory motor (DS-DSVFMM) is proposed. Firstly, the topology structure and operation principle of the DS-DSVFMM are introduced. The equivalent magnetic circuit model is established, and the principle of online flux regulation is analyzed. Then, based on the structural characteristics of the proposed motor, the optimization objectives and constraints are established for the multi-objective optimization design. The structural parameters with high sensitivity to the motor performance are selected, and the response surface models of the key parameters for average torque, torque ripple and iron loss are constructed. The NSGA-II algorithm is used for the multi-objective optimization design, and the Pareto solution set and optimal structural parameters are obtained. The electromagnetic performance of the motor before and after optimization are compared and analyzed. It shows that the average torque is increased and torque ripple is decreased effectively. Meanwhile, the good flux regulation performance of the DS-DSVFMM is demonstrated, which verifies the effectiveness of the proposed motor topology and optimization method. Finally, the DS-DSVFMM prototype is fabricated and verified by no-load and load experiments.